![Bunn IMIX Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/bunn/imix/imix_service-and-repair-manual_2830512049.webp)
49
Pin
Application IMIX
Type
Values
J1-1
Program connector
J1-2
Program connector
J1-3
Program connector
J1-4
Program connector
J1-5
Program connector
J1-6
Program connector
J1-7
Program connector
J1-8
Program connector
J1-9
Program connector
J1-10
Program connector
J2-1
Auger 1
Output 0 to 24 VDC
Adjustable to change dispense rate
J2-2
Auger 2
Output 0 to 24 VDC
Adjustable to change dispense rate
J2-3
Auger 3
Output 0 to 24 VDC
Adjustable to change dispense rate
J2-4
Auger 4
Output 0 to 24 VDC
Adjustable to change dispense rate
J2-5
Auger 5
Output 0 to 24 VDC
Adjustable to change dispense rate
J2-6
Ground
Gnd
DC ground
Self explanatory
J3-1
Display board
I/O
Comm
Communication
J3-2
Display board
GRND GRND
GRND
J3-3
Display board
I/O
Comm
Communication
J3-4
Display board
8 VDC
Display power supply
J4-1
N/A
N/A
N/A
N/A
J4-2
Dispense/Whipper 1
Output L1
activated with dispense
J4-3
Dispense/Whipper 2
Output L1
activated with dispense
J4-4
Dispense/Whipper 3
Output L1
activated with dispense
J4-5
Dispense/Whipper 4
Output L1
activated with dispense
J4-6
Dispense/Whipper 5
Output L1
activated with dispense
J4-7
N/A
N/A
N/A
N/A
J4-8
Temp Sensor
GRND GND
J4-9
Level Probe
GRND GND
J4-10
N/A
N/A
N/A
N/A
J4-11
Temp Sensor
Input
0 to 5 VDC
Monitors tank temperature
J4-12
Rinse position
Input
0VDC in rinse
Signals rinse position from rinse run switch
J4-13
Inlet
Output 120 VAC
Inlet activated with refill circuit
J4-14
Safety in
Input
L1
Float switch supplies refill only
J4-15
L1
Input
120 VAC
Self explanatory
J4-16
Neutral/L2
Input
N or 120VAC
Nuetral or second leg
J4-17
Dispense/Whipper
Output N or L2
Nuetral or second leg
J4-18
Dispense/Whipper
Output N or L2
Nuetral or second leg
J4-19
N/A
N/A
N/A
N/A
J4-20
N/A
N/A
N/A
N/A
J4-21
Ground
grnd
grnd
Ground for rinse/run switch
J4-22
N/A
N/A
N/A
N/A
J4-23
Run Position
Input
0VDC in run
Signals run position from rinse run switch
J4-24
Level Probe
signal
Low AC
Monitors tank level
J5-1
Transformer
Output 120 VAC
L1
J5-2
Transformer
Output 0 or 120VAC
N or L2
J5-3
N/A
N/A
N/A
N/A
J5-4
Transformer
Input
24 VAC
Supplies power for board operation
J5-5
Transformer
Input
24 VAC
Supplies power for board operation
iMIX-3S+/5S+ I/O 38831.####
INPUT/OUTPUT CHART
for IMIX-3S+ & 5S+
42032 060109
Содержание IMIX
Страница 10: ...10 42032 060109 NOTES ...
Страница 46: ...46 42032 060109 ...
Страница 48: ...48 42032 060109 ...