FIG. 13-1  LIMIT THERMOSTAT - MyCafé AP

Location:

The tanks are located inside the back access panel.

NOTE:

 AutoPod tanks are not serviceable.

TANK HEATERS

Test Procedures:

1.  With a voltmeter, check voltage across the white 

wire (120V Models) or red wire (120/208-240V 

Models) from the terminal block and black wire 

from the control board. Connect brewer to the 

power source. The indication must be line voltage 

(during a heating cycle).

2.  Disconnect the brewer from the power source.

If voltage is present as described, proceed to #3.

If voltage is not present as described, refer to the 

Wiring Diagrams and check wiring harness. If harness 

checks ok, replace control board.

3.   Disconnect the wires from the tank heater.

4.   Check for continuity between terminals.

NOTE: There should be no continuity between either 

terminal to sheath (ground).

If continuity is present as described, reconnect the 

wires, the tank heater is ok.

If continuity is not present as described, replace the 

tank.

Removal and Replacement: MyCafé AP

1.  Remove the top cover and back access panel.

2.  Drain water from the tank.

3.  Disconnect all the hoses from the tank.

4.  Disconnect the wires from tank heater terminals.

5.  Remove two screws securing tank lid to chassis. 

6.  Remove six screws securing tank lid to tank.

7.  Remove two nuts securing heater to tank lid.

8.  Installation is the reverse order.

TANKS

LIMIT THERMOSTAT

Location:

The limit thermostat is located on the tank lid (MyCafé 

AP) or on the side of the tank (AutoPod).

Test Procedures:

1.  Disconnect the brewer from the power source.

2.  Disconnect the wires from the limit thermostat.

3.  With an ohmmeter, check for continuity across 

the limit thermostat terminals.

If continuity is present as described, the limit thermostat 

is operating properly.

If continuity is not present as described, replace the 

limit thermostat.

Removal and Replacement:

1.  Remove the wires from limit thermostat termi-

nals.

2.  Carefully slide the limit thermostat out from under 

the retaining clip and remove limit thermostat.

3.  Carefully slide the new limit thermostat into the 

retaining clip. Ensure the metal face has good contact 

with tank.

1.  Connect wires to limit thermostat terminals.

41169 120711

Содержание AutoPOD My Cafe AP

Страница 1: ...the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way t...

Страница 2: ...ons to this warranty or to make additional warranties that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied...

Страница 3: ...Page 3 41169 120711 CONTENTS Warranty 2 Contents 3 Troubleshooting 4 Diagnostics 9 Service 10 Schematics 25...

Страница 4: ...ermanent If an intermittent condition is encountered the cause will likely be a switch contact or a loose connection at a terminal or crimp Solenoid removal requires interrupting the water supply to t...

Страница 5: ...to solenoid valve 5 Solenoid valve defective 1 Lime build up on probe 2 Water Level Sensing System 1 Refill valve stuck open Make sure water is ON Clean out debris Contact plumber Check wiring CBA Rep...

Страница 6: ...up Check wiring Replace Replace heater Check wiring Replace CBA Check replace Check replace Check replace Plumbing lines should not rest on the counter top The brewer must be connected to a cold wate...

Страница 7: ...alibrated 3 Flow meter 4 AIR TIME set too low 1 Water shut off 2 Flowmeter inletblocked limedup 3 Flow meter defective 4 No voltage to solenoid valve 5 Solenoid valve defective Brewer has shut down du...

Страница 8: ...OBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT cont 1 Sprayhead blockage 2 Tubing between tank and spray head blocked limed up 3 Pump seal leaking 4 No voltage to pump 5 Pump defective 1 Sprayhead 2 Wate...

Страница 9: ...ggered when load on motor ex ceeds 1 amp Tripping GFCI breaker 1 Pod s binding pod holder as sembly 2 Debris on sensor blocking optical path 3 Timingdiskcouplerloose slipping 4 No voltage to motor 5 M...

Страница 10: ...rvicing except when electrical tests are re quired and the test procedure specifically states to plug in the brewer WARNING Disconnect the brewer from the power source before the removal of any panel...

Страница 11: ...Ifvoltageispresent andbrewerdoesnotpower on replace board Removal and Replacement 1 Disconnect brewer from power source 2 DisconnectthecordfromL1 L2onthecontrolboard 3 Disconnect the connectors from...

Страница 12: ...areas 4 Connect the voltmeter leads to the coil terminals Turn on the valve with the test mode Set the meter to AC volts The indication should be line voltage when activated If voltage is present as d...

Страница 13: ...cement MyCaf AP 1 Remove the top cover and back access panel 2 Drain water from the tank 3 Disconnect all the hoses from the tank 4 Disconnect the wires from tank heater terminals 5 Remove two screws...

Страница 14: ...is working correctly check limit thermostat and TCO on 230V models If voltage is not present as described proceed to 4 4 Disconnecttemperatureprobefromcontrolboard Check the resistance across the two...

Страница 15: ...i nals of the vent valve Activate valve in the TEST OUTPUTS program mode The indication must be 12 vdc 2 Coil resistance should be 28 8 10 Removal and Replacement 1 Disconnect the brewer from the powe...

Страница 16: ...3 Disconnect the brewer from the power source If voltage is present as described circuit is working correctly If voltage is not present as described proceed to 4 4 Disconnect two pin connector from m...

Страница 17: ...or Activatemotorinthe TESTOUTPUTS programmode Theindicationmustbe120vdcon all models NOTE 230v models provide 120vdc to the motor 230v models have capacitors installed on motor for CE compliance Conti...

Страница 18: ...a DC voltmeter check voltage across the two wiresatJ7onmainCBA Blackprobetoblackwire red probe to red wire Connect the brewer to the power source The indication must be 12 vdc 3 Disconnect the brewer...

Страница 19: ...LOAD HOT WATER button drives the pod holder out to the door open position L indicates the assembly is in load postion FIG 19 1a b B indicates the assembly is in home postion FIG 19 2a b D indicates t...

Страница 20: ...N INDEX B MOTOR DUMP NEXT LOAD 19 3b DUMP POSITION INDEX D MOTOR DUMP NEXT LOAD FIG 19 2a UNBLOCKED FIG 19 3aBLOCKED EJECTOR ASSEMBLY INDEX L MOTOR DUMP NEXT LOAD FIG 19 1b LOAD POSITION FIG 19 1a UNB...

Страница 21: ...k of ejector 7 Disconnect harnesses from index motor sensor and display board 8 Remove 5 screws from housing FIG 20 2 9 Spread back of housing to clear bracket assem bly and slide housing towards fron...

Страница 22: ...emove top cover 4 Loosen top Allen screw farthest from motor FIG 21 1 5 Remove plastic plug from ejector floor Insert Al len wrench through hole and loosen bottom Allen screw farthest from motor FIG 2...

Страница 23: ...all the way to the back position 9 Power up brewer and Press OPEN CLOSE but ton to close pod door 10 Slightly loosen 2 nuts securing motor mounting bracket to ejector wall FIG 22 3 11 Insert alignmen...

Страница 24: ...al assembly 5 If check valve pulls apart remove remaining piece with a spring hook or dental pick 6 Install new check valve with O ring end in first WARNING NEVER RE USE CHECK VALVE AF TER IT HAS BEEN...

Страница 25: ...P BREW PUMP INDEX MOTOR AIR PUMPS J5 1 5 6 10 AIR VENT SOLENOID WHI BLU 12V WHI BLU PNK GRN WHI WHI LEVEL PROBE 5V HOT 4 5V COLD TANK HEATER BLU BLK LIMIT THERMOSTAT WHI WHI GND 12V GND 12V 12VDC REVE...

Страница 26: ...MPS J5 1 5 6 10 RELAY NC NO C AIR VENT SOLENOID WHI RED WHI RED WHI BLU WHI BLU HOT WATER TANK PNK GRN WHI WHI LEVEL PROBE t 5V HOT 4 5V COLD 5V HOT 4 5V COLD TANK HEATER B L K RED BLK BLK WHI LIMIT T...

Страница 27: ...TER TANK PNK GRN WHI WHI LEVEL PROBE t 5V HOT 4 5V COLD 5V HOT 4 5V COLD TANK HEATER B L K W H I WHI BLK BLK RED LIMIT THERMOSTAT WHI BREW TANK W H I B L K BLK LIMIT THERMOSTAT t BLK BLK TANK HEATER S...

Отзывы: