Page 9
41169 120711
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
MISCELLANEOUS
"INDEX MOTOR FAULT"
CBA has sensed that motor as-
sembly has not rotated timing
disk within 15 seconds.
"REPLACE SEAL SOON/NOW!!!"
Counter set for 25000 brews.
Early models were set at 5000.
"PATH CLEAR?
ANY SWITCH TO CONTINUE"
Formerly "OBSTRUCTION"
Triggered when load on motor ex-
ceeds .1 amp.
Tripping GFCI breaker.
1. Pod(s) binding pod holder as-
sembly.
2. Debris on sensor blocking optical
path.
3. Timing disk coupler loose/slipping.
4. No voltage to motor.
5. Motor defective.
6. Sensor defective.
1. "PM"
1. Pods causing obstruction.
2. Loose Sprayhead/seal
Tank heater defective.
Remove blockage.
Clean.
Tighten. Refer to alignment procedure.
Check wiring/CBA.
Check/replace.
Check/replace.
Replace sprayhead seal and reset
counter.
Clear obstruction. Empty pod bin
if needed.
Check/replace.
Check/replace.