42
240V~/60Hz Pump:
Spas equipped with a 240V~/60Hz pump can only be
Permanently-Connected.240V~/60Hz Permanently-Connected Installation:
Your spa has been configured to operate only on 240V~/60Hz power.
Permanently-Connected 240V~/60Hz spas requires a GFCI protected, 4-wire
(Line 1, Line 2, Neutral and Ground), 240V~/60Hz, 50A, Single-Phase, dedi-
cated electrical circuit. It is important that this circuit is dedicated (not being
used by any other electrical appliance) or the spa may not function properly.
Installation must be in accordance with all national and local wiring rules.
240v~/60Hz Equipment
(Model Bf15-u.S./Can Dual-Pump Spas)
All spas not listed as voltage convertible are equipped with (model BFE15)
240V~/60Hz equipment. This equipment only operates on a 240V~/60Hz
electrical service.
Permanently-Connected 240V~/60Hz spas require a GFCI protected, 4-wire
(Line 1, Line 2, Neutral and Ground),
240V~/60Hz, 50A, Single-Phase, dedicated electrical circuit. It is required
that this circuit is dedicated (not being used by any other electrical appliance)
or the spa may not function properly.
Installation must be in accordance with all national and local wiring rules.
230v~/50Hz EQuIPMEnT
(Model BfG15-all European Spas)
Spas are equipped with 230V~/50Hz pumps and 240V~/50Hz equipment
(Model BF04). This 230V~/50Hz equipment allows the spa to operate only on
a 230V~/50Hz electrical service.
Permanently-Connected 230V~/50Hz, 32A spas require a GFCI protected,
240V~/50Hz, 32A Single-Service, 16A Single-Service, or 16A – 16A Dual-
Service 400V~, 3N, 16Ax3, 50Hz, dedicated electrical circuit. It is important
that this circuit is dedicated (not being used by any other electrical appliance)
or the spa may not function properly. For specific conversion instructions,
please refer to the system wiring diagram inside the Control System Box (lo-
cated in the spa’s equipment compartment). Installation must be in accordance
with all national and local wiring rules.
Connecting the electrical service to the spa
IMPORTANT:
Installation must be in accordance with all national and
local wiring rules and performed by a licensed Electrician.
Step 1:
Choose one of the three available conduit entry points. (Yellow decal)
Step 2:
Determine the conduit diameter and drill a hole that is properly sized
for the conduit (¾” conduit drill 1-1/8” hole, 1” conduit drill 1-3/8” hole). Use
the + as the locator for the center of the hole. The hole saw must go through
two layers of plastic. There is a 1” space between both layers.
Step 3:
Push the conduit through the hole until it comes out into the equipment area.
Step 4:
Remove the faceplate to the Control System Box
Step 5:
Connect the conduit to the Control System Box using a Liquid Tight Connector.
Step 6:
Run the required wires through the conduit to the Control System Box.
Step 7:
Connect the electrical service wires to the terminal block located in
the Control System Box.
Step 8:
Replace the Control System Box faceplate and the equipment com-
partment door. The electrical hook-up is complete.
Содержание I 331 Series