eathing Air Requir

ements/A

ssembling the Air Pump

Breathing Air Requirements

Air Quality

The Free-Air

®

 pump’s inlet filters MUST be located in a clean breath-

able air location at all times. Breathable air drawn into the inlet filters 
MUST meet at least the requirements for Type 1 Gaseous Air de-
scribed in the Compressed Gas Association Commodity Specification 
G-7.1 (Grade D or higher), as specified by Federal Law 30 CFR, Part 
11, Subpart J, 11.12(b).
The requirements of Grade D breathable air include:
* Oxygen ................................19.5 - 23.5% 
*  Hydrocarbons (condensed) 

in mg/m

3

 of gas ....... 5 mg/m

3

 maximum

* Carbon Monoxide ....... 10 ppm maximum 
* Carbon Dioxide...... 1,000 ppm maximum
* No toxic contaminants at levels which would make the air unsafe to  

 

 breath.
Refer to the C.G.A. Commodity Specification G-7.1 for complete details. 
It is available from:
 

Compressed Gas Association 

 

500 Fifth Avenue 

 

New York, NY 10036

Assembling the Free-Air Pump

The only assembly required on an EDP30 or EDP50 Pump is to attach 
the air supply hose quick-disconnect pod(s) to the pump’s manifold.
1. Remove the pump from its shipping pallet and the air supply hose 

quick-disconnect pod(s) from their shipping carton.

2. The air supply hose quick-disconnect pods can be located in the 

work area, up to 300 feet from the pump. Use Bullard’s Cat. No. 
V60, 100 foot extension hose to extend the pod(s): (If V60 extension 
hose IS NOT required, go to instruction 3).
a) Attach the V60 extension 

hose to the pump’s manifold. 
If extending only one pod, 
connect the V60 hose to the 
manifold Kamlok coupler 
that is not plugged. Lock the 
Kamlok male fitting on the 
hose to the Kamlok female 
coupler on the manifold 
(Figure 1).
If you are not using the other manifold coupler, leave the Kamlok 
plug installed to prevent air from freely flowing.

NOTE

Due to the relatively high volume of air pumped through the V60 
hose, the first 100 feet of hose may tend to vibrate. The vibration 
dissipates as additional lengths of hose are added.

b) If additional lengths of V60 
extension hose are required, connect 
them together using the Kamlok 
couplers (Figure 2).
DO NOT EXTEND THE POD(S) MORE 
THAN 300 FEET (3 LENGTHS OF 
V60 HOSE) FROM THE PUMP’S 
MANIFOLD.

c) Attach the pod(s) to the end of the 

V60 hose. They should be connected 
so that the handle and pressure 
relief valve are on top of the pod 
(See Figure 3).
Lock the Kamlok Male Fitting on the 
Pod to the Female Coupling on the 
Hose.

3. If the V60 extension hose is not 

required, assemble the pod(s) directly to 
the pump’s manifold. The pods should 
be connected so that the handle and 
pressure relief valve are on top of the 
pod (See Figure 4).
If using only one pod, connect it to the 
manifold Kamlok coupler that is not 
plugged. Lock the Kamlok male fitting 
on the pod to the female coupler on the pump’s manifold.
Leave the plug in the other coupler to prevent air from freely flowing.

Figure 1

Figure 2

Figure 3

Figure 4

Содержание EDP30

Страница 1: ...require expensive carbon monoxide monitors high temperature alarms or airline filters No calibration is required Read all instructions before using your Free Air pump This manual provides detailed in...

Страница 2: ...tact the respirator manufacturer or Bullard s Customer Service Department at 877 BULLARD or 1 859 234 6616 3 Supplied air respirators used with this pump MUST NOT be worn in any atmosphere immediately...

Страница 3: ...EDP30 PUMP Pump s Output Air Pressure psig Pump s Output Air Volume cfm Maximum Recommended Mask Respirators Maximum Recommended Hood Respirators Motor Amp Load 5 32 Six Four 16 10 30 Six Four 18 15...

Страница 4: ...pod s If V60 extension hose IS NOT required go to instruction 3 a Attach the V60 extension hose to the pump s manifold If extending only one pod connect the V60 hose to the manifold Kamlok coupler tha...

Страница 5: ...ry Carbon Vane 4 vanes MAXIMUM AIR PRESSURE 30 psig 15 psig AIR FLOW 30 cfm at 10 psig 50 cfm at 10 psig PRESSURE RELIEF VALVES Adjustable Pre Set to open at 34 psig when adjusted fully closed Adjusta...

Страница 6: ...f the respirator system being used to the quick disconnect coupler s or the pod s Figure 6 NOTE If your respirator s air supply hose approved by NIOSH as part of the respirator system being used will...

Страница 7: ...respirators NOTE If the pod s are attached directly to the pump manifold the pressure gauges should always read within 5 of each other If the gauge on the manifold reads substantially higher than the...

Страница 8: ...p with the gasket g Insert four 4 new filter cartridges in the seats and reassemble the caps and wing nuts to hold the cartridges in place h Reassemble the pod Tighten the wing nuts and bolts together...

Страница 9: ...ough the respirator s air supply hose until it reaches ambient air temperature 2 If pressure relief valves are set too high reset to a lower pressure Be sure the outlet pressure remains in the approve...

Страница 10: ...Gauge 0 15 psig S19683 Pressure Gauge 0 30 psig S19688 Pressure Gauge 0 60 psig S2084 Drive Belt Matched Pair EDP30 S2085 Drive Belt Matched Pair EDP50 S2089 Kamlok Adapter Male Pod S2090 Kamlok Coup...

Страница 11: ...to factory inspection In warranty product of current design will be subjected to a rehandling charge less freight originally allowed All material must be shipped with transportation charges prepaid B...

Страница 12: ...e outlet filter cartridge is multi layered with 40 micron size particles of activated carbon a sorbent bed with an exposed carbon surface of more than 15 000 square feet Vapor removal efficiency 90 95...

Отзывы: