Free-Air® Pumps 

User Manual

3

Pump P

erf

ormance T

ables

Number of Respirators that can be used 

with Pumps

Depending on the pump model and style of respirator(s) being used, 
Bullard EDP30 and EDP50 Free-Air Pumps will supply air for up to ten 
(10) workers. 

Refer to the respirator’s MSHA/NIOSH approved pressure range and 
permissible air supply hose length. The Respirator’s Minimum Approved 
Pressure must be 30 psig or less if using Model EDP30 or 15 psig or 
less if using Model EDP50.

 

Maximum number of respirators at different air pressure 
readings that can be used with EDP30 and EDP50 pumps

On the chart below, find the relevant Output Air Pressure (psig) 
corresponding to the respirator’s approved pressure range to 
determine the pump’s total air volume (cfm), and maximum number 
of respirators that can be used at that air volume. For additional 
information, the ampere loading on the pump’s motor is shown in the 
right hand column.

EDP30 PUMP

Pump’s Output Air 

Pressure (psig)

Pump’s Output Air 

Volume (cfm)*

Maximum 

Recommended Mask 

Respirators**

Maximum 

Recommended Hood 

Respirators**

Motor Amp Load***

5

32

Six

Four

16

10

30

Six

Four

18

15

28

Five

Four

19

20

26

Five

Three

22

25

24

Four

Three

24

30

22

Four

Three

26

EDP30 PUMP WITH FRIGITRON 2000 AIR CONDITIONER

18-25

24-25

None

Two

17

EDP50 PUMP

Pump’s Output Air 

Pressure (psig)

Pump’s Output Air 

Volume (cfm)*

Maximum 

Recommended Mask 

Respirators**

Maximum 

Recommended Hood 

Respirators**

Motor Amp Load***

5

54

Ten

Seven

22

10

50

Ten

Seven

25

15

46

Nine

Six

28

* Assumes that no air is being dumped from Pressure Relief Valves.
**  It should be noted that the Minimum Air Flow required for each tight-fitting mask style respirator is four (4) cfm and for 

each hood style respirator is six (6) cfm.

   The ratings which appear here, therefore, are conservative, but reflect Bullard’s position that worker respiratory 

protection is enhanced when air flow available to the respirator wearer is above the NIOSH required minimums.

***  Motor Starter Overload Heater should not be exposed to more than 30 Amps of continuous electrical draw.

PUMP PERFORMANCE TABlES

Содержание EDP30

Страница 1: ...require expensive carbon monoxide monitors high temperature alarms or airline filters No calibration is required Read all instructions before using your Free Air pump This manual provides detailed in...

Страница 2: ...tact the respirator manufacturer or Bullard s Customer Service Department at 877 BULLARD or 1 859 234 6616 3 Supplied air respirators used with this pump MUST NOT be worn in any atmosphere immediately...

Страница 3: ...EDP30 PUMP Pump s Output Air Pressure psig Pump s Output Air Volume cfm Maximum Recommended Mask Respirators Maximum Recommended Hood Respirators Motor Amp Load 5 32 Six Four 16 10 30 Six Four 18 15...

Страница 4: ...pod s If V60 extension hose IS NOT required go to instruction 3 a Attach the V60 extension hose to the pump s manifold If extending only one pod connect the V60 hose to the manifold Kamlok coupler tha...

Страница 5: ...ry Carbon Vane 4 vanes MAXIMUM AIR PRESSURE 30 psig 15 psig AIR FLOW 30 cfm at 10 psig 50 cfm at 10 psig PRESSURE RELIEF VALVES Adjustable Pre Set to open at 34 psig when adjusted fully closed Adjusta...

Страница 6: ...f the respirator system being used to the quick disconnect coupler s or the pod s Figure 6 NOTE If your respirator s air supply hose approved by NIOSH as part of the respirator system being used will...

Страница 7: ...respirators NOTE If the pod s are attached directly to the pump manifold the pressure gauges should always read within 5 of each other If the gauge on the manifold reads substantially higher than the...

Страница 8: ...p with the gasket g Insert four 4 new filter cartridges in the seats and reassemble the caps and wing nuts to hold the cartridges in place h Reassemble the pod Tighten the wing nuts and bolts together...

Страница 9: ...ough the respirator s air supply hose until it reaches ambient air temperature 2 If pressure relief valves are set too high reset to a lower pressure Be sure the outlet pressure remains in the approve...

Страница 10: ...Gauge 0 15 psig S19683 Pressure Gauge 0 30 psig S19688 Pressure Gauge 0 60 psig S2084 Drive Belt Matched Pair EDP30 S2085 Drive Belt Matched Pair EDP50 S2089 Kamlok Adapter Male Pod S2090 Kamlok Coup...

Страница 11: ...to factory inspection In warranty product of current design will be subjected to a rehandling charge less freight originally allowed All material must be shipped with transportation charges prepaid B...

Страница 12: ...e outlet filter cartridge is multi layered with 40 micron size particles of activated carbon a sorbent bed with an exposed carbon surface of more than 15 000 square feet Vapor removal efficiency 90 95...

Отзывы: