background image

www.bullard.com

Replacement Parts and Accessories

Replacement Parts list

FOR BOTH EDP30 AND EDP50 FREE-AIR

®

 PUMPS

Cat. No. 

Description

23611 

Inlet Filter 

26701 

Gasket, Pod, Filter Side 

27161 

Gasket, Pod, Cover Side 

28151 

Pressure Relief Valve EDP30 

28152 

Pressure Relief Valve EDP50 

S16481 

Quick-Disconnect Coupler,1/2” 

 

Industrial Interchange 

S17101 

Outlet Filter Cartridge 

S19681 

Pressure Gauge, 0-15 psig 

S19683 

Pressure Gauge, 0-30 psig 

S19688 

Pressure Gauge, 0-60 psig 

S2084 

Drive Belt, Matched Pair, EDP30 

S2085 

Drive Belt, Matched Pair, EDP50 

S2089 

Kamlok Adapter, Male, Pod 

S2090 

Kamlok Coupler, Female, Manifold

Optional Accessory Items

 

Cat. No. 

Description

26781 

Remote pod, EDP30 (Includes six quick-disconnect  

 

couplers, pressure gauge, pressure relief valve and    

 

outlet filter cartridges)

26782 

Remote pod, EDP50, same as above

V23 

Outlet Coupler Adaptor, converts 1/2” 

 

Industrial Interchange  

 

Coupler to 3/8” Female NPT

V60 

100 Foot 1 1/4” I.D. Pod  

 

Extension Hose 

10

Replacement P

arts 

Содержание EDP30

Страница 1: ...require expensive carbon monoxide monitors high temperature alarms or airline filters No calibration is required Read all instructions before using your Free Air pump This manual provides detailed in...

Страница 2: ...tact the respirator manufacturer or Bullard s Customer Service Department at 877 BULLARD or 1 859 234 6616 3 Supplied air respirators used with this pump MUST NOT be worn in any atmosphere immediately...

Страница 3: ...EDP30 PUMP Pump s Output Air Pressure psig Pump s Output Air Volume cfm Maximum Recommended Mask Respirators Maximum Recommended Hood Respirators Motor Amp Load 5 32 Six Four 16 10 30 Six Four 18 15...

Страница 4: ...pod s If V60 extension hose IS NOT required go to instruction 3 a Attach the V60 extension hose to the pump s manifold If extending only one pod connect the V60 hose to the manifold Kamlok coupler tha...

Страница 5: ...ry Carbon Vane 4 vanes MAXIMUM AIR PRESSURE 30 psig 15 psig AIR FLOW 30 cfm at 10 psig 50 cfm at 10 psig PRESSURE RELIEF VALVES Adjustable Pre Set to open at 34 psig when adjusted fully closed Adjusta...

Страница 6: ...f the respirator system being used to the quick disconnect coupler s or the pod s Figure 6 NOTE If your respirator s air supply hose approved by NIOSH as part of the respirator system being used will...

Страница 7: ...respirators NOTE If the pod s are attached directly to the pump manifold the pressure gauges should always read within 5 of each other If the gauge on the manifold reads substantially higher than the...

Страница 8: ...p with the gasket g Insert four 4 new filter cartridges in the seats and reassemble the caps and wing nuts to hold the cartridges in place h Reassemble the pod Tighten the wing nuts and bolts together...

Страница 9: ...ough the respirator s air supply hose until it reaches ambient air temperature 2 If pressure relief valves are set too high reset to a lower pressure Be sure the outlet pressure remains in the approve...

Страница 10: ...Gauge 0 15 psig S19683 Pressure Gauge 0 30 psig S19688 Pressure Gauge 0 60 psig S2084 Drive Belt Matched Pair EDP30 S2085 Drive Belt Matched Pair EDP50 S2089 Kamlok Adapter Male Pod S2090 Kamlok Coup...

Страница 11: ...to factory inspection In warranty product of current design will be subjected to a rehandling charge less freight originally allowed All material must be shipped with transportation charges prepaid B...

Страница 12: ...e outlet filter cartridge is multi layered with 40 micron size particles of activated carbon a sorbent bed with an exposed carbon surface of more than 15 000 square feet Vapor removal efficiency 90 95...

Отзывы: