background image

www.bullard.com

Care Instructions

The Bullard Eclipse LDX Thermal Imager requires little maintenance. For best results, after 
each use:

•  Clean the outside of the unit with mild soap or detergent.
•  Wipe the lens with a soft cloth.
•  Clean the display with a soft cloth.
•  Check screw tightness on cover display.
•  Store your thermal imager in the optional truck mount or in the delivery case provided.
•  Maintain your thermal imagers using a proper program

Cleaning the Lens

The Bullard Eclipse LDX lens is recessed in an impact resistant bezel. The lens can be cleaned 
with a soft cloth and soapy water as required.

Replacing the Video Display Cover 

Window

The display cover (

Figure 6

) has a scratch-resistant hard 

coating to minimize marring. However, if heavy scratching or 
gouging does occur, the cover window can be replaced. To do 
this, remove the four Phillips head screws along the sides of the 
window. Remove the plastic display cover window and replace with 
a new one (part number: ECLLDWINDOW). Do not over-tighten.

CAUTION

The Eclipse LDX Thermal Imager is extremely sensitive to intense, radiant heat sources. 
Never point the unit at the sun or any other source of extreme radiant heat, as this could 
severely damage the thermal imager.
Do not use solvents or paint thinners to clean your Bullard Eclipse LDX Thermal Imager, 
as they could permanently mar the surface or degrade the protective properties of the 
casing.
Do not intentionally submerge the unit underwater or subject the unit to high- pressure 
water.
Do not attempt to disassemble the Bullard Eclipse LDX Thermal Imager. Disassembling the 
unit voids all warranties. 
Failure to observe these instructions may result in product damage. Any damage caused 
by improper care is not covered under warranty. 

 WARNING

Thermal imaging is not a technology designed to replace current firefighting tactics. 
Rather, it is a tool that allows firefighters to be more effective and to make better 
decisions.

Service

If your Bullard Thermal Imager is not performing properly, please contact Bullard Customer 
Service at 877-BULLARD (285-5273). Outside the US & Canada, call 1-859-234-6611. Describe 
the problem to the Bullard representative as completely as possible. For your convenience, 
your representative will try to help you diagnose or correct the problem over the phone. 
Before returning your Bullard thermal imager, you should verify with your representative that 
the product should be returned to Bullard. Bullard Customer Service will provide you with 
written permission and a return authorization number.
If the return is a non-warranty repair, a Bullard Customer Service Representative or your 
local distributor will provide you with a repair invoice estimate. To authorize repair, you must 
provide a purchase order to your distributor for the amount of the estimate. Once Bullard 
receives authorization from your local distributor, we will issue you a return authorization 
number so that you can return the unit to Bullard. Bullard will repair the unit and ship it from 
our factory within 48 business hours. If the cost of repairs exceeds the stated quote by more 
than 15% or by more than $100, a Bullard representative will reestimate your repair and 
your local distributor will contact you for authorization to complete repairs. After repairs are 
completed and the goods have been returned to you, your distributor will invoice you for the 
actual repair amount.

NOTE

Do not attempt to disassemble the sealed case of your Bullard Thermal Imager. 
If the unit is not functioning properly, return it to Bullard (as described in the 
Service section) for evaluation. Disassembling the unit voids all warranties.

Decontaminate and clean your Thermal Imager to remove any hazardous or contaminated 
materials that may have settled on the product during use. Laws and/or shipping regulations 
prohibit the shipment of hazardous or contaminated materials. Products suspected of 
contamination will be professionally decontaminated at the customer’s expense. Returned 
products will be inspected upon return to the Bullard facility. If the repair is under warranty, 
Bullard will repair the unit and ship it from our factory within 48 business hours.

Warranty

Bullard warrants to the original purchaser that this new Bullard Eclipse LDX Thermal 
Imager and all features/accessories installed in the unit are free of defects in materials 
and workmanship under intended use and service for a period of five (5) years from date 
of activation. This warranty applies to new Bullard Thermal Imagers only. Units sold as 
refurbished, upgraded, or otherwise not newly manufactured by Bullard are excluded from 
this warranty. Bullard’s obligation under this warranty is limited to repairing or replacing, 
at Bullard’s option, articles that are returned within the warranty period and that, after 
examination, are shown to Bullard’s satisfaction to be defective, subject to the following 
limitations:

a) Article must be returned to Bullard with shipping charges prepaid.
b) Article must not be altered from its original configuration.
c) Article must not have been misused, abused, or damaged in transport.
d) Maintenance and field replaceable items, if defective, are covered under warranty for a 

ninety (90) day period from the date of purchase. These items include:

• Batteries
• Straps
•  Display covers
•  AC/DC adapters

Bullard provides a limited lifetime warranty on the Eclipse LDX outer shell. This warrants 
that the outer shell is free of defects in materials and workmanship under intended use 
and service for the original purchaser. Bullard’s obligation under this warranty is limited 
to repairing or replacing, at Bullard’s option, articles that after examination are shown to 
Bullard’s satisfaction to be defective, subject to the following limitations:

1. Article must not be altered from its original configuration.
2. Article must not have been misused, abused, or damaged in transport.
3. When the outer shell is obsolete and Bullard no longer stocks the part, the limited 

lifetime warranty will be terminated.

In no event shall Bullard be responsible for damages, loss of use, or other indirect, 
incidental, consequential or special costs, expenses or damages incurred by the purchaser, 
notwithstanding that Bullard has been advised of the possibility of such damages.
Any implied warranties, including warranties of merchantability and fitness for  
a particular purpose, are limited in duration to five (5) years from the date of  
manufacture. Some states do not allow the exclusion or limitation of incidental or 
consequential damages, or allow limitations on how long an implied warranty lasts, so the 
above limitations or exclusions may not apply to you. This warranty gives you specific legal 
rights, and you may have other rights which vary from state to state.

3

Bullard ECLLDX Thermal Imager 

User Manual

Figure 6

Содержание Eclipse LDX

Страница 1: ...ches 20 charge NOTE The battery status indicator readings can be affected by environmental conditions When the unit is used for extended periods in temperature extremes the indicator may drop to red m...

Страница 2: ...ow indicated on the button With the battery release switch engaged slide the battery into the groove in the cavity located at the bottom of the unit You will hear an audible click when the battery is...

Страница 3: ...e goods have been returned to you your distributor will invoice you for the actual repair amount NOTE Do not attempt to disassemble the sealed case of your Bullard Thermal Imager If the unit is not fu...

Страница 4: ...ontact your local Bullard distributor Bullard Center 2421 Fortune Drive Lexington KY 40509 USA 877 BULLARD 285 5273 Tel 1 859 234 6616 Fax 1 859 246 0243 Americas Operations 1898 Safety Way Cynthiana...

Страница 5: ...orno Indicador de estado de la bater a Un indicador de estado de la bater a ubicado en la zona inferior central de la pantalla indica la carga restante de la bater a en la c mara Eclipse LDX La carga...

Страница 6: ...o de las bater as Bloquear Desbloquear la bater a La c mara termogr fica Eclipse LDX est equipada con un mecanismo que permite el bloqueo seguro de la bater a Figura 3 Este mecanismo no es necesario p...

Страница 7: ...Bullard reparar la unidad y la enviar desde nuestra f brica en un plazo de 48 horas laborables Si el costo de las reparaciones supera el presupuesto estipulado en m s de un 15 o en m s de 100 un repr...

Страница 8: ...3 Tel 1 859 234 6616 Fax 1 859 246 0243 Americas Operations 1898 Safety Way Cynthiana KY 41031 USA 877 BULLARD 285 5273 Tel 1 859 234 6616 Fax 1 859 234 8987 Bullard GmbH Dieselstrasse 8a 53424 Remage...

Страница 9: ...s activera toutes les 5 secondes 5 minutes en fonction de l environnement Indicateur d tat de la batterie Un indicateur d tat de la batterie situ au centre de la portion inf rieure de l cran indique...

Страница 10: ...unit Pendant ce temps le point rouge recouvert d un X sera affich Utilisation des batteries Verrouillage d verrouillage de la batterie Cet imageur thermique Eclipse LDX est quip d un m canisme qui pe...

Страница 11: ...Avant de retourner votre imageur thermique de Bullard vous devriez v rifier aupr s de votre repr sentant pour savoir si le produit doit tre retourn Bullard Le Service la client le de Bullard vous env...

Страница 12: ...es et il se peut que vous ayez d autres droits qui varient d une province l autre 60500510816F AM ENESFR 0220 2020 Bullard Tous droits r serv s CareFree Eclipse et Electronic Thermal Throttle sont des...

Отзывы: