31
6.4
Adjusting the cover pressure
Tools needed
• 1 hexagon socket spanner size 1.5
• 1 hexagon socket spanner size 2,5
• 1 hexagon socket spanner size 3
C1
C2
C3
C4
Fig. 6.4/1:
Adjusting the cover pressure
1. Rotate the lever (C3) clockwise and swivel the cover until fully open.
2. Loosen the lever fixing screw (C4) with the hexagon socket spanner SW3.
Withdraw the screw.
3. Loosen the clamping screw (C1) with the hexagon socket spanner size 1.5 (approx. 1,5
turns).
4. Insert the hexagon socket spanner size 2.5 into the adjusting screw through the lever
screw-hole. Turn the adjusting screw clockwise initially by approx. 90°.
5. Close and lock the cover.
If the cover will not close, keep turning the adjusting screw back (clockwise) by approx.
15° until the cover closes easily.
6. Actuate the trigger.
• If the cover now closes correctly, proceed at step 7.
• If the cover still does not close correctly, repeat the adjustment from section 4.
7. Open the cover again.
8. Tighten the clamping screw (C1).
9. Fit the lever fixing screw (C4).
Servicing/maintenance
GB