9. INSTALLATION (Gas safe engineer only)
12/22
9.2 Ensure 20 cm. air gap from any wall or other
vertical surface . It is strongly recommended that fire
safety protection instructions are observed. It is
recommended to comply with fire protections rules.
9.3 If the appliance is operated with LPG cylinders the distance between the appliance and the
gas cylinder must be minimum 50 cm. The LPG cylinders to be used must be selected
according to the gas category and pressures in the section "NOZZLES, SETTINGS, GAS
CATEGORIES AND PRESSURES". The device can be used with 47 kg. LPG industrial
hoses. LPG gas regulator with a capacity of at least 10 kg / h should be used.
The regulator must be selected according to the gas type and pressure of the
appliance.The parts protected by the manufacturer or its representative must not be
adjusted by the installation staff. It should always be properly ventilated in and around the
gas cylinder compartment, with continuous fresh air supply and with an adequate
ventilation system to ensure that there is no unburned gas accumulation.
9.4 Authorized service personnel must check the GAS INFORMATION labelled on the appliance
to ensure that the labelled gas type and pressure data matches the type and pressure of
the gas installation available.
9.5 If the information labelled on the appliance does not match with the gas type and pressure
of the gas installation at customers site, the operations when changing the gas system
mentioned in Point 11 must be carried out in following order.
9.5A Check whether the gas installation pipe diameter at the gas inlet of the appliance complies
with the specification for gas inlet pipe diameter mentioned in TECHNICAL DATA section.
If the pipe diameter is larger than those mentioned in TECHNICAL DATA section, pipe
diameter must be decreased to desired size using a reducing coupling. If the pipe
diameter is smaller than that mentioned in TECHNICAL DATA section, the appliance
should not be connected to this gas installation since it will not operate efficiently. This
gas installation must be changed.
9.5B After making these checks authorized service personnel can install flexible gas pipe to the
gas inlet pipe of the appliance. Gas supply pipe or hose must complies with the applicable
national regulations and shall be periodically examined and amended according to
national regulations.
9.1
The appliance must be installed on a sturdy and durable floor. Ensure surface
is level. When appliance is in position engage brakes on castors.
MINIMUM DISTANCE BETWEEN THE GAS CYLINDER AND THE APPLIANCE SHOULD BE 50 cm.
50
LPG