Carbon Monoxide (CO) Detection and Shut-off System
This generator features CO WARNING, which will automatically shut-off if dangerous levels of CO is
detected.
Carbon monoxide (also known as CO) can be dangerous for humans and pets. Carbon monoxide
poisoning can lead to death in a very short time. It is called “the silent killer” because it is odorless,
tasteless and invisible: you may be exposed without knowing it.
The CO Detection module monitors for the accumulation of poisonous CO gas found in engine
exhaust when the generator is running. If CO detector detects increasing levels of CO gas, it
automatically shuts off the engine. CO detector only monitors when the engine is running. Generators
are intended to be used outdoors, far from occupied buildings and the exhaust pointed away from
personnel and buildings. However, if misused and operated in a location that results in the
accumulation of CO, like indoors or in a partially enclosed area, CO detector shuts off the engine,
notifies the user of what has happened and directs the user to read the instruction action label for
steps to take.
CO detector is not a substitute for an indoor carbon monoxide alarm.
After a shut-off, a blinking RED light in the CO detector badge on the side of the generator provides
notification that the generator was shut off due to an accumulating CO hazard. The RED light will
blink for at least five minutes after a CO shut-off. Move the generator to an open, outdoor area and
point the exhaust away from people and occupied buildings. Once relocated to a safe area, the
generator can be restarted and the proper electrical connections made to supply electrical power. The
RED light will stop blinking automatically upon engine re-start. Introduce fresh air and ventilate the
location where the generator had shut down.
If a CO detector system fault has occurred and no longer provides protection, the portable generator
is shut off automatically and the YELLOW light will blink for at least five minutes in the CO detector
badge to notify the user of the fault. The CO detector module can only be diagnosed and repaired by
a trained technician at the dealer. The generator can be re-started, but may continue to shut-off.
CO detector will detect the accumulation of Carbon Monoxide from other fuel burning sources such
as engine powered tools or propane heaters used in the area of operation. For example, if another
generator is used and the exhaust is pointed at a CO detector equipped generator, CO detector may
initiate a shut-off due to rising CO levels. This is not an error. Hazardous Carbon Monoxide has been
detected. The user must take action to move and re-direct these devices to better dissipate Carbon
Monoxide far away from personnel and occupied buildings.
202107
Содержание Sportsman GEN2K
Страница 7: ...ITEM GEN2K Portable Gasoline Generator 7 ...
Страница 22: ...ITEM GEN2K Portable Gasoline Generator 22 PARTS DIAGRAM ...
Страница 23: ...ITEM GEN2K Portable Gasoline Generator 23 ...
Страница 24: ...ITEM GEN2K Portable Gasoline Generator 24 ...
Страница 25: ...ITEM GEN2K Portable Gasoline Generator 25 s ...
Страница 26: ...ITEM GEN2K Portable Gasoline Generator 26 ...
Страница 27: ...ITEM GEN2K Portable Gasoline Generator 27 ...
Страница 28: ...ITEM GEN2K Portable Gasoline Generator 28 ...
Страница 29: ...ITEM GEN2K Portable Gasoline Generator 29 ...
Страница 30: ...ITEM GEN2K Portable Gasoline Generator 30 ...
Страница 31: ...ITEM GEN2K Portable Gasoline Generator 31 ...
Страница 32: ...ITEM GEN2K Portable Gasoline Generator 32 ...
Страница 33: ...ITEM GEN2K Portable Gasoline Generator 33 ...
Страница 34: ...ITEM GEN2K Portable Gasoline Generator 34 ...