Buffalo Tools GEN3250 Скачать руководство пользователя страница 6

GEN3250   3250 Surge Watts/2500 Running Watts Portable Generator  

6  

 

                                                                      

 

Powerful Voltage:

 This generator produces powerful voltage, which can result in electrocution. 

• ALWAYS ground this generator before using it. (See “Ground the Generator” section in this manual). 
• Only electrical devices should be plugged into this generator, either directly or with an extension cord. NEVER connect a building electrical 

system to this generator without a qualified electrician. Such connections must isolate generator power from utility power and comply with local 

electrical laws and codes. Failure to comply can create a back feed into utility lines creating an electrocution hazard, which may result in serious 

injury or death to utility workers. Such a back feed may cause this generator to explode, burn and create fires when utility power is restored. 
• Use a ground fault circuit interrupter (GFCI) in highly conductive areas such as metal decking or steel work. GFCIs are available in-line with 

some extension cords. 

• Do not use this generator in wet conditions (rain, snow, active sprinkler system, wet hands, etc.). Always keep this generator dry and operate 

it with dry hands. 
• Do not touch bare wires or outlets (receptacles). 

• Do not allow children or non-qualified persons to operate this generator. 
  

                                                                      

 

High Temperatures:

 This generator produces heat when in operation. Temperatures near the exhaust can exceed 150 Degrees 

Fahrenheit (65 Degrees Celsius). 

• Do not touch hot surfaces. Observe all warning placards on this generator denoting hot surfaces. 
• Allow this generator to cool for several minutes after use before touching the engine, muffler or other areas that are hot during operation and 

before storing indoors. 

• Hot exhaust may ignite some materials. Keep flammable materials away from this generator. 

• Keep at least several feet of clearance on all sides of this generator during operation. Do not enclose this generator in any structure. 
 
                                                                      

 

Usage:

 Misuse of this generator can damage it or shorten its life. 

• Use this generator only for its intended purpose. 

• Operate this generator only on a dry, level surface. Do not secure the generator with a chain or rope, which would prevent it from being moved 

in an emergency. 
• Allow this generator to run for several minutes before connecting any electrical devices. 

• Promptly turn off any malfunctioning devices and disconnect them. 

• Do not operate an excessive number of electrical devices in excess of the wattage capacity of this generator. 

• Do not turn on electrical devices until after they are connected to this generator. 
• Turn off all connected electrical devices before stopping this generator. 
 

                                                                                 

 

Usage:

 Consult a physician(s) before using this generator if using a pacemaker. Electromagnetic fields in close proximity to a heart 

pacemaker could cause a pacemaker to malfunction or fail. Caution is necessary when near the engine’s recoil starter. 
 
                                                                               

 

Usage:

 Prolonged exposure to high noise levels can be hazardous to hearing. Always wear ANSI-approved hearing protection when 

operating or working around the generator when it is running. 
 

                                                                               

 

Usage:

 This generator is not intended to power sensitive electronic equipment such as TVs, DVD players, stereos, desktop 

computers or laptop computers without the use of an appropriate line conditioner and/or surge protector (both not included). 
Sensitive electronic equipment should be operated on approved inverter type generators or pure sine wave generators. For additional 

information consult the devices operation manual or call customer service  at 1-866-460-9436 Monday - Friday, 8 AM - 4 PM Central Time. 
 

                                                                                 

 

Usage:

 Avoid the use of extension cords if possible. If you choose to use them, be sure they are sized adequately to handle the flow of 

electricity. An undersized cord can overheat, short out and cause a fire. 
 

 

Содержание GEN3250

Страница 1: ...right to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN THIS PRODUCT TO THE RETAILER CON...

Страница 2: ...ation 6 5 HP Engine 4 Stroke OHV Air Cooled Recoil Start Engine Shut Off Switch 1 12V DC Outlet 2 120V Outlets EPA approved Run time 8 hrs 50 load Fuel type Gasoline Only Automatic Low Oil Shutdown In...

Страница 3: ...e Generator 12 Subsequent Use Of This Generator 13 Step 1 Verify Oil Level 13 Step 2 Verify Gas Level 13 Step 3 Ground The Generator 13 STARTING THE GENERATOR 14 USING THE GENERATOR 15 AC Usage 15 DC...

Страница 4: ...echnician to come to the owner to make the warranty repair or pay for the repair to be made at a local non authorized service center The provisions of this paragraph apply only for the contiguous stat...

Страница 5: ...f clearance on all sides to allow proper ventilation for this generator Chemicals According to the State of California the exhaust from this generator contains chemicals known to cause cancer birth de...

Страница 6: ...ep at least several feet of clearance on all sides of this generator during operation Do not enclose this generator in any structure Usage Misuse of this generator can damage it or shorten its life Us...

Страница 7: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 7...

Страница 8: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator...

Страница 9: ...ded STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETAILER Item List Set of 2 DC connector wires for...

Страница 10: ...r contains no oil in the engine crankcase The correct quantity of oil is equal to the oil capacity of the engine crankcase and is 20 0 fluid oz 0 60 L for this Model GEN3250 Portable Generator Add the...

Страница 11: ...NOTE Because gasoline can expand do not fill the fuel tank to the very top 4 Securely tighten the fuel tank cap and immediately wipe up any spilled gasoline with a dry cloth Model GEN3250 Fuel Tank Ca...

Страница 12: ...fresh unleaded gasoline with an octane rating of 87 or higher according to Step 2 Add Gasoline of the Using this Generator for the First Time section of this manual Model GEN3250 Fuel Tank Capacity ga...

Страница 13: ...osition 4 Move the choke lever to the closed position 5 Set the engine switch to the on position 6 Slowly pull on the recoil starter handle shown in Figure 4 until a slight resistance is felt Then pul...

Страница 14: ...ge of the selected devices exceeds the rated wattage of the generator DO NOT connect all of the devices Select a combination of the electrical devices that will have a total wattage less than or equal...

Страница 15: ...20 Volt outlet Connect 12 Volt DC loads to the 12 Volt outlet Even though this generator has an overall rated wattage of 3250 do not attempt to draw more than 2500 Watts from the 120 Volt outlet Draws...

Страница 16: ...Wire Gauge Amps Watts 120V Watts 240V 8 wire 10 wire 12 wire 14 wire 16 wire 2 5 300 600 NR 1000 600 375 250 5 600 1200 NR 500 300 200 125 7 5 900 1800 NR 350 200 125 100 10 1200 2400 NR 250 150 100 5...

Страница 17: ...nd procedures according to the schedule in Figure 7 Never perform maintenance procedures while this generator is running Allow this generator to cool before commencing any maintenance procedures Keep...

Страница 18: ...0 fluid oz 0 60 L To drain the oil from this generator The oil should be changed after the first 20 hours of operation The oil should then be changed every 6months or for every 100 hours of use time...

Страница 19: ...e brush to clean any dirt from around the spark plug base and then re gap the spark plug 6 Screw the spark plug back into place on this generator by using the included spark plug wrench 7 Replace the...

Страница 20: ...Close the choke Engine is out of gasoline Add gasoline Engine is filled with contaminated and or old gasoline Drain gasoline from the engine and add new gasoline Spark plug is dirty Clean spark plug S...

Страница 21: ...nch of gas is in the tank Generator starts but won t stay running Carburetor needs to be reset Adjust the fuel screw on the carburetor Turn the screw clockwise until it bottoms out then turn it counte...

Страница 22: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 22 GEN3250 3250 SURGE WATTS 2500 RUNNING WATTS PARTS DIAGRAM...

Страница 23: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 23 GEN3250 3250 SURGE WATTS 2500 RUNNING WATTS PARTS LIST...

Страница 24: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 24 GEN3250 3250 SURGE WATTS 2500 RUNNING WATTS ENGINE PARTS DIAGRAM...

Страница 25: ...nition Assy 1 24 A168F 1 24 Oil Seal 2 25 A168F 1 25 Packing 1 26 A168F 1 26 Signal Magnifier 1 27 A168F 1 27 Oil Drain Plug 2 28 A168F 1 28 Oil Drain Plug Washer 2 29 A168F 1 29 Crankcase Assy 1 30 A...

Страница 26: ...A168F 1 72 Valve Cap 1 73 A168F 1 73 Intake Valve Spring Retainer 1 74 A168F 1 74 Exhaust Valve Spring Retainer 1 75 A168F 1 75 Valve Spring 2 76 A168F 1 76 Spark Plug 1 77 A168F 1 77 Cylinder Head Co...

Отзывы: