Buffalo Tools GEN3250 Скачать руководство пользователя страница 14

GEN3250   3250 Surge Watts/2500 Running Watts Portable Generator  

14  

 

USING THE GENERATOR 

 

                                                                                              

   

• USE THIS GENERATOR ONLY OUTDOORS IN NON-CONFINED AREAS. DO NOT SECURE THE GENERATOR WITH A CHAIN OR ROPE, AS 

THIS WILL MAKE IT DIFFICULT TO MOVE IN AN EMERGENCY. 

• Keep at least several feet of clearance on all sides to allow proper ventilation for this generator. 
After the engine has been running for several minutes, electrical devices may be connected to this generator. 

 

AC Usage 

 

Electrical devices running on AC current may be connected according to their wattage requirements. The rated (running) and surge wattage for this 
Model GEN3250 Portable Generator is 2,500 and 3,250 respectively. 

 
Model GEN3250 Rated (Running) Wattage 

2500 

Model GEN3250 Surge Wattage 

3250 

 

The rated (running) wattage corresponds to the maximum wattage a generator can output on a continuous basis. 

 

The surge wattage corresponds to the maximum amount of power a generator can output for a short time. Many electrical devices, such as a 
refrigerator, require short bursts of extra power for starting and stopping fan motors, etc., in addition to their listed rated wattage. Motorized devices 

typically require more than their rated wattage for startup. The surge wattage ability of a generator allows for this extra power requirement. 

 

The total running wattage requirement of the electrical devices connected to a generator should not exceed the rated wattage of the generator itself. 
To calculate the total wattage requirement of the electrical devices to be connected, look up the rated (running) wattage of each device and add 

these numbers together to find the total wattage that all of the devices together will draw from the generator. If the total wattage of the selected 

devices exceeds the rated wattage of the generator, DO NOT connect all of the devices. Select a combination of the electrical devices that will have 

a total wattage less than or equal to the rated wattage for the generator. 
 
                                                                                                

   

This generator can run at its surge wattage capacity for only a short time. Connect electrical devices requiring a rated (running) wattage 

equal to or less than the rated wattage of this generator. Never connect devices requiring a rated wattage equal to the surge wattage of a 

generator. 
 
A device's rated (running) wattage should be listed somewhere on the device itself and/or in its manual. If the wattage specification for a device is not 

available, the wattage can be calculated by multiplying the Voltage requirement (120 or 240) by the Amperage drawn. 

 

Watts = Volts x Amperes 
 

Or, the wattage required by a device can be estimated by using the following chart. The chart provides only estimates and it is better to know the 

exact wattage of each electrical device to be powered by this generator. 

 

 

 

 

 

Electrical Device 

Rated (Running) Watts 

Additional Surge Watts 

air compressor (1 - 1/2 HP) 

2500 

2500 

airless sprayer (1/3 HP) 

600 

1200 

coffee maker 

1500 

computer w/17 inch monitor 

800 

deep freezer 

500 

500 

electric drill (1/2 HP) 

1000 

1000 

furnace fan blower (1/2 HP) 

800 

1300 

hot plate 

2500 

microwave oven (1000 watt) 

1000 

quartz halogen work light 

1000 

refrigerator/freezer (18 Cu. Ft.) 

800 

1600 

saw - circular (7 1/4 inch) 

1500 

1500 

stereo receiver 

450 

electric stove - single element 

1500 

sump pump 

800 

1200 

television (27 inch color) 

500 

well water pump (1/3 HP) 

1000 

2000 

window air conditioner (10000 BTU) 

1200 

1800 

window fan 

300 

600 

Connect electrical devices to this generator 

according to the following procedure: 

 
Allow the engine to run for several minutes after it 

has been started. 

 

Confirm that the electrical device is switched off 
prior to plugging it into this generator.  

Содержание GEN3250

Страница 1: ...right to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN THIS PRODUCT TO THE RETAILER CON...

Страница 2: ...ation 6 5 HP Engine 4 Stroke OHV Air Cooled Recoil Start Engine Shut Off Switch 1 12V DC Outlet 2 120V Outlets EPA approved Run time 8 hrs 50 load Fuel type Gasoline Only Automatic Low Oil Shutdown In...

Страница 3: ...e Generator 12 Subsequent Use Of This Generator 13 Step 1 Verify Oil Level 13 Step 2 Verify Gas Level 13 Step 3 Ground The Generator 13 STARTING THE GENERATOR 14 USING THE GENERATOR 15 AC Usage 15 DC...

Страница 4: ...echnician to come to the owner to make the warranty repair or pay for the repair to be made at a local non authorized service center The provisions of this paragraph apply only for the contiguous stat...

Страница 5: ...f clearance on all sides to allow proper ventilation for this generator Chemicals According to the State of California the exhaust from this generator contains chemicals known to cause cancer birth de...

Страница 6: ...ep at least several feet of clearance on all sides of this generator during operation Do not enclose this generator in any structure Usage Misuse of this generator can damage it or shorten its life Us...

Страница 7: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 7...

Страница 8: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator...

Страница 9: ...ded STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETAILER Item List Set of 2 DC connector wires for...

Страница 10: ...r contains no oil in the engine crankcase The correct quantity of oil is equal to the oil capacity of the engine crankcase and is 20 0 fluid oz 0 60 L for this Model GEN3250 Portable Generator Add the...

Страница 11: ...NOTE Because gasoline can expand do not fill the fuel tank to the very top 4 Securely tighten the fuel tank cap and immediately wipe up any spilled gasoline with a dry cloth Model GEN3250 Fuel Tank Ca...

Страница 12: ...fresh unleaded gasoline with an octane rating of 87 or higher according to Step 2 Add Gasoline of the Using this Generator for the First Time section of this manual Model GEN3250 Fuel Tank Capacity ga...

Страница 13: ...osition 4 Move the choke lever to the closed position 5 Set the engine switch to the on position 6 Slowly pull on the recoil starter handle shown in Figure 4 until a slight resistance is felt Then pul...

Страница 14: ...ge of the selected devices exceeds the rated wattage of the generator DO NOT connect all of the devices Select a combination of the electrical devices that will have a total wattage less than or equal...

Страница 15: ...20 Volt outlet Connect 12 Volt DC loads to the 12 Volt outlet Even though this generator has an overall rated wattage of 3250 do not attempt to draw more than 2500 Watts from the 120 Volt outlet Draws...

Страница 16: ...Wire Gauge Amps Watts 120V Watts 240V 8 wire 10 wire 12 wire 14 wire 16 wire 2 5 300 600 NR 1000 600 375 250 5 600 1200 NR 500 300 200 125 7 5 900 1800 NR 350 200 125 100 10 1200 2400 NR 250 150 100 5...

Страница 17: ...nd procedures according to the schedule in Figure 7 Never perform maintenance procedures while this generator is running Allow this generator to cool before commencing any maintenance procedures Keep...

Страница 18: ...0 fluid oz 0 60 L To drain the oil from this generator The oil should be changed after the first 20 hours of operation The oil should then be changed every 6months or for every 100 hours of use time...

Страница 19: ...e brush to clean any dirt from around the spark plug base and then re gap the spark plug 6 Screw the spark plug back into place on this generator by using the included spark plug wrench 7 Replace the...

Страница 20: ...Close the choke Engine is out of gasoline Add gasoline Engine is filled with contaminated and or old gasoline Drain gasoline from the engine and add new gasoline Spark plug is dirty Clean spark plug S...

Страница 21: ...nch of gas is in the tank Generator starts but won t stay running Carburetor needs to be reset Adjust the fuel screw on the carburetor Turn the screw clockwise until it bottoms out then turn it counte...

Страница 22: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 22 GEN3250 3250 SURGE WATTS 2500 RUNNING WATTS PARTS DIAGRAM...

Страница 23: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 23 GEN3250 3250 SURGE WATTS 2500 RUNNING WATTS PARTS LIST...

Страница 24: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 24 GEN3250 3250 SURGE WATTS 2500 RUNNING WATTS ENGINE PARTS DIAGRAM...

Страница 25: ...nition Assy 1 24 A168F 1 24 Oil Seal 2 25 A168F 1 25 Packing 1 26 A168F 1 26 Signal Magnifier 1 27 A168F 1 27 Oil Drain Plug 2 28 A168F 1 28 Oil Drain Plug Washer 2 29 A168F 1 29 Crankcase Assy 1 30 A...

Страница 26: ...A168F 1 72 Valve Cap 1 73 A168F 1 73 Intake Valve Spring Retainer 1 74 A168F 1 74 Exhaust Valve Spring Retainer 1 75 A168F 1 75 Valve Spring 2 76 A168F 1 76 Spark Plug 1 77 A168F 1 77 Cylinder Head Co...

Отзывы: