Buffalo Tools GEN3250 Скачать руководство пользователя страница 4

GEN3250   3250 Surge Watts/2500 Running Watts Portable Generator  

4  

 

RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS 

 
What You Need to Know About Safety Instructions 

 

Warning and Important Safety Instructions appearing in this manual are not meant to cover all possible conditions and situations that 
may occur. Common sense, caution and care must be exercised when operating or cleaning tools and equipment. 
 
Always contact your dealer, distributor, service agent or manufacturer about problems or conditions you do not understand.

 

 

 

 

This is the safety alert symbol. It is used to alert you to potential 
personal injury hazards. Obey all safety messages that follow this 

symbol to avoid possible injury or death. 

 

 

 

 

DANGER indicates an imminently hazardous situation 

which, if not avoided, will result in death or serious injury.

 

 

 

WARNING indicates a potentially hazardous situation which, 

if not avoided, could result in death or serious injury.

 

 

 

CAUTION indicates a potentially hazardous situation which, 
if not avoided, may result in minor or moderate injury.

 

 

 

CAUTION used without the safety alert symbol indicates a  
potentially hazardous situation which, if not avoided, may  

result in property damage.

 

THIS ENGINE MEETS U.S. EPA EMISSION STANDARDS UNDER 40 CFR 1054.625 . 

 
The emission-related warranty is valid for two (2) years. Keep the purchase receipt and mail in the product registration card for proof of purchase.  

NB Corp limits emission-related warranty repairs to authorized service centers for owners located within 100 miles of an authorized service center. 

For owners located more than 100 miles from an authorized service center, NB Corp will, in its sole discretion, either pay for shipping costs to and 

from an authorized service center, provide for a service technician to come to the owner to make the warranty repair, or pay for the repair to be made 
at a local non-authorized service center. The provisions of this paragraph apply only for the contiguous states, excluding the states with high-altitude 

areas identified in 40 CFR part 1068, Appendix III. 

 

To exercise this warranty, DO NOT RETURN TO RETAILER. Instead, call Customer Service toll free at 1-866-460-9436 (email address 
[email protected]) and you will be instructed on where to take the engine for warranty service. Take the generator and proof of purchase (your 

receipt) to the repair facility recommended by the Customer Service Representative. The warranty does not extend to generators damaged or 

affected by fuel contamination, accidents, neglect, misuse, unauthorized alterations, use in an application for which the product was not designed 

and any other modifications or abuse.  
 

90 DAY LIMITED WARRANTY   

 

Generators are warranted to be free from defects in materials and workmanship for a period of 90 days from date of original purchase. NB Corp. is  
not liable for any indirect, incidental or consequential damages from the sale or use of this product. Any implied warranties are limited to 90 days as 

stated, or as otherwise stated, in this written limited warranty. Some states do not allow the exclusion or limitation of incidental or consequential 

damages. Some states do not allow limitation on the length of an implied warranty. NB Corp will repair or replace, at its discretion, any part that is 

proven to be defective in materials or workmanship under normal use during the 90 day warranty period. Warranty repairs or replacements will be 
made without charge for parts or labor. Parts replaced during warranty repairs will be considered as part of the original product and will have the 

same warranty period as the original product. This warranty gives you specific legal rights, and you may have other rights that vary from state to 

state. 

 

Содержание GEN3250

Страница 1: ...right to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN THIS PRODUCT TO THE RETAILER CON...

Страница 2: ...ation 6 5 HP Engine 4 Stroke OHV Air Cooled Recoil Start Engine Shut Off Switch 1 12V DC Outlet 2 120V Outlets EPA approved Run time 8 hrs 50 load Fuel type Gasoline Only Automatic Low Oil Shutdown In...

Страница 3: ...e Generator 12 Subsequent Use Of This Generator 13 Step 1 Verify Oil Level 13 Step 2 Verify Gas Level 13 Step 3 Ground The Generator 13 STARTING THE GENERATOR 14 USING THE GENERATOR 15 AC Usage 15 DC...

Страница 4: ...echnician to come to the owner to make the warranty repair or pay for the repair to be made at a local non authorized service center The provisions of this paragraph apply only for the contiguous stat...

Страница 5: ...f clearance on all sides to allow proper ventilation for this generator Chemicals According to the State of California the exhaust from this generator contains chemicals known to cause cancer birth de...

Страница 6: ...ep at least several feet of clearance on all sides of this generator during operation Do not enclose this generator in any structure Usage Misuse of this generator can damage it or shorten its life Us...

Страница 7: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 7...

Страница 8: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator...

Страница 9: ...ded STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETAILER Item List Set of 2 DC connector wires for...

Страница 10: ...r contains no oil in the engine crankcase The correct quantity of oil is equal to the oil capacity of the engine crankcase and is 20 0 fluid oz 0 60 L for this Model GEN3250 Portable Generator Add the...

Страница 11: ...NOTE Because gasoline can expand do not fill the fuel tank to the very top 4 Securely tighten the fuel tank cap and immediately wipe up any spilled gasoline with a dry cloth Model GEN3250 Fuel Tank Ca...

Страница 12: ...fresh unleaded gasoline with an octane rating of 87 or higher according to Step 2 Add Gasoline of the Using this Generator for the First Time section of this manual Model GEN3250 Fuel Tank Capacity ga...

Страница 13: ...osition 4 Move the choke lever to the closed position 5 Set the engine switch to the on position 6 Slowly pull on the recoil starter handle shown in Figure 4 until a slight resistance is felt Then pul...

Страница 14: ...ge of the selected devices exceeds the rated wattage of the generator DO NOT connect all of the devices Select a combination of the electrical devices that will have a total wattage less than or equal...

Страница 15: ...20 Volt outlet Connect 12 Volt DC loads to the 12 Volt outlet Even though this generator has an overall rated wattage of 3250 do not attempt to draw more than 2500 Watts from the 120 Volt outlet Draws...

Страница 16: ...Wire Gauge Amps Watts 120V Watts 240V 8 wire 10 wire 12 wire 14 wire 16 wire 2 5 300 600 NR 1000 600 375 250 5 600 1200 NR 500 300 200 125 7 5 900 1800 NR 350 200 125 100 10 1200 2400 NR 250 150 100 5...

Страница 17: ...nd procedures according to the schedule in Figure 7 Never perform maintenance procedures while this generator is running Allow this generator to cool before commencing any maintenance procedures Keep...

Страница 18: ...0 fluid oz 0 60 L To drain the oil from this generator The oil should be changed after the first 20 hours of operation The oil should then be changed every 6months or for every 100 hours of use time...

Страница 19: ...e brush to clean any dirt from around the spark plug base and then re gap the spark plug 6 Screw the spark plug back into place on this generator by using the included spark plug wrench 7 Replace the...

Страница 20: ...Close the choke Engine is out of gasoline Add gasoline Engine is filled with contaminated and or old gasoline Drain gasoline from the engine and add new gasoline Spark plug is dirty Clean spark plug S...

Страница 21: ...nch of gas is in the tank Generator starts but won t stay running Carburetor needs to be reset Adjust the fuel screw on the carburetor Turn the screw clockwise until it bottoms out then turn it counte...

Страница 22: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 22 GEN3250 3250 SURGE WATTS 2500 RUNNING WATTS PARTS DIAGRAM...

Страница 23: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 23 GEN3250 3250 SURGE WATTS 2500 RUNNING WATTS PARTS LIST...

Страница 24: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 24 GEN3250 3250 SURGE WATTS 2500 RUNNING WATTS ENGINE PARTS DIAGRAM...

Страница 25: ...nition Assy 1 24 A168F 1 24 Oil Seal 2 25 A168F 1 25 Packing 1 26 A168F 1 26 Signal Magnifier 1 27 A168F 1 27 Oil Drain Plug 2 28 A168F 1 28 Oil Drain Plug Washer 2 29 A168F 1 29 Crankcase Assy 1 30 A...

Страница 26: ...A168F 1 72 Valve Cap 1 73 A168F 1 73 Intake Valve Spring Retainer 1 74 A168F 1 74 Exhaust Valve Spring Retainer 1 75 A168F 1 75 Valve Spring 2 76 A168F 1 76 Spark Plug 1 77 A168F 1 77 Cylinder Head Co...

Отзывы: