Subsequent Use of this Generator 

 

For subsequent uses of this generator after the first use, certain steps still must be completed to prepare it for operation. 

 
IMPORTANT: Be familiar with the procedures described in the previous section titled “Using the Generator for the First Time” of this 

manual. If not, review this section now. 

 

Step 1 - Verify Oil Level 

 

It is important to check the oil level in the engine crankcase before each use to ensure that there is sufficient quantity. 
1. Verify that this generator is on a level surface. 

2. Unscrew the oil filler/dipstick cap from the engine. 

3. With a dry cloth, wipe the oil off of the dipstick that is located on the inside of the cap. 

4. Fully insert the dipstick without screwing the filler/dipstick cap and then remove again. There should be oil on the dipstick. If there is no oil on the 

dipstick, or oil is visible only at the very end of the dipstick, add oil until the engine crankcase is filled. (See “Changing/Adding Oil” in the 

“Maintenance/Care” section of this manual). 

5. Confirm that the oil filler/dipstick cap is properly screwed in place when finished verifying the oil level. 
 

Step 2 - Verify Gas Level 

 

Before starting this generator, verify that there is sufficient gasoline in the fuel tank. The fuel gauge, located on the top of this generator, indicates  

the gas level currently in the fuel tank. If necessary, add fresh unleaded gasoline with an octane rating of 87 or higher according to “Step 2 - Add 
Gasoline” of the “Using this Generator for the First Time” section of this manual. 

 
Model GEN3250 Fuel Tank Capacity (gals /L) 

4 / 15.14 

Model GEN3250 Fuel Type 

Fresh, Unleaded Gasoline Octane Rating 87 or Higher 

 

                                                                                            

  

Gasoline and gasoline fumes are highly flammable and explosive. Handling fuel can result in serious injury or burns. 
• Do not fill the fuel tank near a heat, sparks or an open flame. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power 

tools, etc. 

• Always allow several minutes for the engine to cool before refueling. 

• Do not overfill the fuel tank. Always check for fuel spills and immediately wipe them up. Spilled fuel is a fire hazard and causes environmental 
damage. 
 

IMPORTANT: 

• Use only fresh UNLEADED gasoline with an octane rating of 87 or higher. 

• Never use old and/or contaminated gasoline. 
• Never use a mixture of oil and gasoline. 

• Avoid getting dirt and/or water in the fuel tank. 

• Never store generator for extended time with gasoline in the fuel tank. 

 

Step 3 - Ground the Generator 

 

                                                                                           

   

Failure to properly ground this generator can result in electrocution. 
 

Ground this generator by tightening the grounding nut against a grounding wire as previously illustrated in Figure 3. A generally acceptable 

grounding wire is a No. 12 AWG (American Wire Gauge) stranded copper wire. The other end of this grounding wire should be connected to a 

copper or brass grounding rod that is driven into the earth. 
 

Grounding codes can vary by location. Contact a local electrician for information on grounding regulations for your area. 

 

Содержание GEN3250

Страница 1: ...right to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN THIS PRODUCT TO THE RETAILER CON...

Страница 2: ...ation 6 5 HP Engine 4 Stroke OHV Air Cooled Recoil Start Engine Shut Off Switch 1 12V DC Outlet 2 120V Outlets EPA approved Run time 8 hrs 50 load Fuel type Gasoline Only Automatic Low Oil Shutdown In...

Страница 3: ...e Generator 12 Subsequent Use Of This Generator 13 Step 1 Verify Oil Level 13 Step 2 Verify Gas Level 13 Step 3 Ground The Generator 13 STARTING THE GENERATOR 14 USING THE GENERATOR 15 AC Usage 15 DC...

Страница 4: ...echnician to come to the owner to make the warranty repair or pay for the repair to be made at a local non authorized service center The provisions of this paragraph apply only for the contiguous stat...

Страница 5: ...f clearance on all sides to allow proper ventilation for this generator Chemicals According to the State of California the exhaust from this generator contains chemicals known to cause cancer birth de...

Страница 6: ...ep at least several feet of clearance on all sides of this generator during operation Do not enclose this generator in any structure Usage Misuse of this generator can damage it or shorten its life Us...

Страница 7: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 7...

Страница 8: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator...

Страница 9: ...ded STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETAILER Item List Set of 2 DC connector wires for...

Страница 10: ...r contains no oil in the engine crankcase The correct quantity of oil is equal to the oil capacity of the engine crankcase and is 20 0 fluid oz 0 60 L for this Model GEN3250 Portable Generator Add the...

Страница 11: ...NOTE Because gasoline can expand do not fill the fuel tank to the very top 4 Securely tighten the fuel tank cap and immediately wipe up any spilled gasoline with a dry cloth Model GEN3250 Fuel Tank Ca...

Страница 12: ...fresh unleaded gasoline with an octane rating of 87 or higher according to Step 2 Add Gasoline of the Using this Generator for the First Time section of this manual Model GEN3250 Fuel Tank Capacity ga...

Страница 13: ...osition 4 Move the choke lever to the closed position 5 Set the engine switch to the on position 6 Slowly pull on the recoil starter handle shown in Figure 4 until a slight resistance is felt Then pul...

Страница 14: ...ge of the selected devices exceeds the rated wattage of the generator DO NOT connect all of the devices Select a combination of the electrical devices that will have a total wattage less than or equal...

Страница 15: ...20 Volt outlet Connect 12 Volt DC loads to the 12 Volt outlet Even though this generator has an overall rated wattage of 3250 do not attempt to draw more than 2500 Watts from the 120 Volt outlet Draws...

Страница 16: ...Wire Gauge Amps Watts 120V Watts 240V 8 wire 10 wire 12 wire 14 wire 16 wire 2 5 300 600 NR 1000 600 375 250 5 600 1200 NR 500 300 200 125 7 5 900 1800 NR 350 200 125 100 10 1200 2400 NR 250 150 100 5...

Страница 17: ...nd procedures according to the schedule in Figure 7 Never perform maintenance procedures while this generator is running Allow this generator to cool before commencing any maintenance procedures Keep...

Страница 18: ...0 fluid oz 0 60 L To drain the oil from this generator The oil should be changed after the first 20 hours of operation The oil should then be changed every 6months or for every 100 hours of use time...

Страница 19: ...e brush to clean any dirt from around the spark plug base and then re gap the spark plug 6 Screw the spark plug back into place on this generator by using the included spark plug wrench 7 Replace the...

Страница 20: ...Close the choke Engine is out of gasoline Add gasoline Engine is filled with contaminated and or old gasoline Drain gasoline from the engine and add new gasoline Spark plug is dirty Clean spark plug S...

Страница 21: ...nch of gas is in the tank Generator starts but won t stay running Carburetor needs to be reset Adjust the fuel screw on the carburetor Turn the screw clockwise until it bottoms out then turn it counte...

Страница 22: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 22 GEN3250 3250 SURGE WATTS 2500 RUNNING WATTS PARTS DIAGRAM...

Страница 23: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 23 GEN3250 3250 SURGE WATTS 2500 RUNNING WATTS PARTS LIST...

Страница 24: ...GEN3250 3250 Surge Watts 2500 Running Watts Portable Generator 24 GEN3250 3250 SURGE WATTS 2500 RUNNING WATTS ENGINE PARTS DIAGRAM...

Страница 25: ...nition Assy 1 24 A168F 1 24 Oil Seal 2 25 A168F 1 25 Packing 1 26 A168F 1 26 Signal Magnifier 1 27 A168F 1 27 Oil Drain Plug 2 28 A168F 1 28 Oil Drain Plug Washer 2 29 A168F 1 29 Crankcase Assy 1 30 A...

Страница 26: ...A168F 1 72 Valve Cap 1 73 A168F 1 73 Intake Valve Spring Retainer 1 74 A168F 1 74 Exhaust Valve Spring Retainer 1 75 A168F 1 75 Valve Spring 2 76 A168F 1 76 Spark Plug 1 77 A168F 1 77 Cylinder Head Co...

Отзывы: