background image

 
AWELD160   ARC Welder Assembly & Operating Instructions 

 

4

 

 
 

 

Double insulated tools are equipped with a polarized plug (one blade is wider than the other.) This plug 
will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it 
still does not fit, contact a qualified electrician to install a polarized outlet. Do not change the plug in 
any way. 

Double insulation eliminates the need for the three wire grounded power cord and grounded power 

supply system. 

 
Avoid body contact with grounded surfaces such as pipes, radiators, ranges and refrigerators

. There is 

an increased risk of electric shock if your body is grounded. 

 
Do not abuse the cord. Never use the cord to carry the tool or pull the plug from an outlet. Keep the 
cord away from heat, oil, sharp edges, or moving parts. Replace damaged cords immediately

. Damaged 

cords increase the risk of electric shock. 

 
When operating the tool outside, use an outdoor extension cord marked “WA” or “W.” 

These cords are 

rated for outdoor use and reduce the risk of electric shock. Make sure the extension cord being used is in good 
condition. If there are any cuts or nicks (no matter how deep) in the insulation, DO NOT use that cord. Also, 
make sure the extension cord is heavy enough to carry the current needed. DO NOT use small "around-the-
house” lamp extension cords. These cords can easily overheat and/or catch fire when used with power tools. 

 

 

Do not force tool. Use the correct tool for your application. 

The correct tool will do the job better and safer 

at the rate for which it is designed. 

 
Do not use the tool if the power switch does not turn it “ON” or “OFF”. 

Any tool that cannot be controlled 

with the switch is dangerous and must be repaired. 

 

Disconnect the power cord plug from the power source before making any adjustments, changing 

accessories or storing the tool. 

Such preventive safety measures reduce the risk of starting the tool 

accidentally. 

 

                               

                                              

 

People with pacemakers or other electronic devices should consult with a physician before operating 
this product. 

Interruption or failure of the pacemaker could occur when electrical equipment is operated within 

close proximity of electrical devices.  

 

                               

                                           

 

All work areas should be clean and well lit. 

Accidents are more likely to occur in poorly lit and cluttered 

areas.  

 

                               

                                            

 

Keep the power cord in good condition, and replace damaged cords immediately. 

Do not use the cord to 

pull the plug from the outlet. Keep the cord away from materials and surfaces that could damage cords. The 
risk of electric shock increases when the power cord is damaged.  

 

                               

                                            

 

Always use the appropriate extension cord, making sure it is rated for use with power tools. 

Always be 

sure the extension cords are in good condition, free of cuts or nicks in the insulation.  If using the power tool in 
an outside area with an extension cord, make sure the cord is rated for outdoor use.  

 

Содержание AWELD160

Страница 1: ...occur We reserve the right to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT HAVE QUESTIONS OR PROBLEMS DO NOT RETURN THIS PRODUCT TO THE RETAILER CONTACT CUSTOMER SERVICE If you experience a problem or need parts for this product visit our website http www buffalotools com or call our customer help l...

Страница 2: ...ation Absorbed Power 5 4 Kilowatts Power Requirement 230 VAC single phase 60 hz Duty Cycle 10 160 Amps AC Power Consumption 230 VAC 60 Hz Single Phase Open Circuit Voltage 48 VC Thermal Overload Protection AC setting 10 minutes shutdown 3 minutes back on Cables Ground 4 AWG single insulation 6 Torch 4 AWG single insulation 6 Accessories Handle Wire Brush Face Shield Weight 39 6 lbs WARNING Always ...

Страница 3: ... If any parts are missing or broken please call Customer Service at 1 888 287 6981 FOR CONSUMER USE ONLY NOT FOR PROFESSIONAL USE IMPORTANT SAFETY RULES COMMON SENSE AND CAUTION ARE FACTORS WHICH CANNOT BE BUILT INTO ANY PRODUCT THESE FACTORS MUST BE SUPPLIED BY THE OPERATOR Keep your work area clean and well lit Cluttered work benches and dark work areas may cause accidents or injury Do not opera...

Страница 4: ...on cords These cords can easily overheat and or catch fire when used with power tools Do not force tool Use the correct tool for your application The correct tool will do the job better and safer at the rate for which it is designed Do not use the tool if the power switch does not turn it ON or OFF Any tool that cannot be controlled with the switch is dangerous and must be repaired Disconnect the ...

Страница 5: ... correct tool for the job Using the correct tool is safer and faster Make sure the power switch is in good working order If the power switch no longer turns the tool ON or OFF discontinue use and have the tool replaced or repaired Remove the power cord from the power source before storage changing accessories or moving the tool Keep out of reach of children or any untrained person Store tools in a...

Страница 6: ... switch into the ON position Be sure the area is free from all foreign material nails staples or any other material Turn the tool OFF and unplug from the power source before making any changes or adjustments to the tool Do not use solvents containing carbon tetrachloride ammonia or acetone to clean the welder Never use gasoline paint thinner or other caustic chemicals that can damage the plastic p...

Страница 7: ...ctors which cannot be built into this product but must be supplied by the operator This product when used for welding and similar applications produces chemicals known to the State of California to cause cancer and birth defects or other reproductive harm California Health Safety Code 25249 5 et seq Avoid electrical shock Do not permit electrically live parts cables or electrodes to contact skin c...

Страница 8: ...ircuit breaker for fuses 10 While holding the Torch Cable Clamp with electrode clearly out of the way of any grounded objects turn the Power Switch to the On position 11 Place the face shield over your eyes Never look at the ignited arc without ANSI approved arc shaded eye protection face shield Permanent eye damage or blindness can occur Skin burns can occur Never breath arc fumes 12 Stroke the a...

Страница 9: ...decrease the life and increase the wear on the tool Some chemicals can damage the product Do not use harsh chemicals such as gasoline carbon tetrachloride paint thinner etc A qualified repair technician must perform any tool service or repair Service or maintenance performed by unqualified personnel could result in injury Use only identical replacement parts Use of unauthorized parts or failure to...

Страница 10: ...AWELD160 ARC Welder Assembly Operating Instructions 10 AWELD160 201009 ...

Отзывы: