How to use the filter function
:
(1) Select
“
Filter Enable
”
and you can revise the content of the filter.
(2) Select the channel that needs filter function from the sub list of
“
Port
”
.
(3) Select the frame type(Standard or extended frame types) from the “Frame Type” .
(4) On
“
Start ID
”
and
“
End ID
”
rows
,
please fill in the ID of the frame that you want to filter.The
standard frame range is 0~2047
(
0x7FF
)
and the extended frame range is 0~536870911
(0x1FFFFFFF).
(5)After setting up the frame’s filter parameters,please click
“
Write Parameter
”
button and write the
router parameters into the device,then it’s valid.