XT-70 Control Panel
6
XT Analog Inputs:
•
Plenum 1
F
2250 ohm
•
Plenum 2
F
2250 ohm
•
Outside Air
F
2250 ohm
•
Return
F
2250 ohm
•
Pile 1
F
2250 ohm
•
Pile 2
F
2250 ohm
•
Pile 3
F
2250 ohm
•
Pile 4
F
2250 ohm
•
Pile 5
F
2250 ohm
•
Pile 6
F
2250 ohm
•
Pile 7
F
2250 ohm
•
Pile 8
F
2250 ohm
•
Outside Humid %
4-20mA
•
Plenum Humid %
4-20mA
•
Return Humid
%
4-20mA
•
CO2
ppm 4-20mA
XT Digital Inputs:
•
Fan proving
Dry contact
•
Cell pump proving
Dry contact
•
Refrigeration Fail
Dry contact
•
Remote Standby
Dry contact
•
Spare
•
Spare
•
Spare
•
Spare
•
Low Temp
SPDT contact
•
Air Restrict
Dry contact
•
Start / Stop
Dry contact
XT Sensors:
The XT panel can accept a number of different input sensors and has ten solid state 3
amp outputs. In addition, there are two analog outputs that are 0-20mA or 0-10VDC. The fresh air
doors are controlled by two relay outputs.
XT Analog Outputs:
•
Freq Drive
0-20mA / 0-10VDC
•
Refrigeration
0-20mA / 0-10VDC
XT Digital Outputs:
•
Red light
3A 120VAC SS
•
Yellow light
3A 120VAC SS
•
Fan / Green light
3A 120VAC SS
•
Evap cooling pump
3A 120VAC SS
•
Humidifier pump 1
3A 120VAC SS
•
Humidifier pump 2
3A 120VAC SS
•
Heater
3A 120VAC SS
•
Aux 1
3A 120VAC SS
•
Aux 2
3A 120VAC SS
•
Cavity heater
3A 120VAC SS
•
Door open
12VDC/relay
•
Door close
12VDC/relay
Note - The Aux 1, Aux 2, and cavity heater can be set to be interlocked with the Start / Stop
switch, mechanical Low Temp and Air Restriction devices or to operate independently.
1.1