Board Mode
SMART MATRIX
- 2-21 -
Board Mode
This function allows you to set the STOP output activation modes by the Board:
STANDARD
mode: if an error occurs, the system generates the alarm and stops the process until the fault is
corrected.
MONITOR
mode: if an error occurs, the system generates the alarm without stopping the process; if the
cause that generated the alarm is cleared, the signaling disappears without the operator intervention; during
the continuation of the process, other possible faults are normally signaled (option typically used for
extrusion applications)
Enter the
SETUP
menu.
Select
BOARD MODE
.
Set the desired mode:
STANDARD
or
MONITOR
*.
* The
SYNC
option
refers to a special configuration that
cannot be used in a general way
To confirm the selection.
SAVE
to save the settings,
BACK
to go back to previous
screen without saving,
EXIT
to go back to the menu.
The
LOAD I/O CONFIG
wording will appear for a few
seconds, then the display will show the main menu.
SETUP
→
BOARD MODE
Содержание SMART WARP
Страница 1: ...SMART MATRIX WARP Operating Manual ENGLISH Rev 3 0 December 2011 ...
Страница 3: ...Introduction i ...
Страница 4: ......
Страница 9: ...Connections and Electrical Interface 1 ...
Страница 10: ......
Страница 21: ...Operating Instructions 2 ...
Страница 22: ......
Страница 79: ...System Components and Configuration 3 ...
Страница 80: ......
Страница 102: ...SLOW FAST Control Parameters SMART MATRIX 3 22 Page left intentionally blank ...