Lamps (ACT/D) Configuration and Numbering
SMART MATRIX
- 2-17 -
Lamps (ACT/D) Configuration and Numbering
This function allows you to identify the ACT/D modules used to drive the lamps that signal the error
conditions on the machine.
You may assign a lamp to each Row, Column or Bar (according to the priority defined with the
IDENTIFY
function), with the possibility to add a lamp for each Creel.
In case of failure detected by a sensor, the lamp associated to sensor Column or Row or Bar and (if
configured) the lamp associated with the Creel, will light.
Enter the
SETUP
menu.
Select
LAMP CONFIG
.
Select
ACT IDENTIFY
.
Point and select
ACT COL
(*)
Choose whether you use (
ON
) or do not use (
OFF
) the
lamps (ACT/D) associated with the Columns and confim,
then point
ACT CREEL
.
Choose whether you use (
ON
) or do not use (
OFF
) the
lamps (ACT/D) associated with the Creels and confirm,
then point the symbol of 1
st
Board.
(*) If in
SETUP
→
IDENTIFY
the Row or Bar priority was
selected, then
ACT ROW
or
ACT BAR
will appear.
SETUP
→
LAMP CONFIG