13c

13b

14

N

N L1 L2 L3

191 194

EC TR

L

1

L

2

L

3

90°

USO NORMALE  /  NORMAL USE  /  UTILISATION NORMALE  /  USO NORMAL  /

NORMAAL GEBRUIK  /  USO NORMAL  /  NORMAL KULLANIM 

TEST SGANCIO DIFFERENZIALE  /  TEST OF RESIDUAL CURRENT TRIPPING  /  ESSAI DE DECLENCHEMENT DIFFERENTIEL  /  TEST DE DESCONEXIÓN DIFERENCIAL  /  

TEST VAN DIFFERENTIEELSTROOM AFSCHAKELING / TESTE DE DISPARO DIFERENCIAL  /  ARTIK AKIMLA AÇMANIN TESTI  

Schema interno apparecchio magneto termico con differenziale integrato
Internal diagram of breaker with integrated Earth leakage
Schéma interne de l’appareil magnétothermique avec différentiel intégré
Esquema interno del aparato magnetotérmico con diferencial integrado 
Intern schema van vermogensautomaat met integreerd aardlekblok.
Esquema interno de aparelho magnetotérmico com diferencial integrado
Dahili kaçak akım modüllü termik manyetik şalterin iç bağlantı şeması

Prova d’intervento differenziale.
Test of residual current tripping.
Essai de déclenchement différentiel.
Prueba de disparo diferencial 
Test van differentieelstroom  

afschakeling
Teste de disparo diferencial 
Artık akımla açmanın testi.

Ripetere questa prova frequentemente durante l’esercizio.
Repeat this test frequently during service.
Répéter cet essai fréquemment pendant l’exercice.
Repetir esta prueba frecuentemente durante su utilización.
Herhaal deze test regelmatig.
Repetir este teste freqüentemente. 
Çalışma süresince sıkça bu testi gerçekleştirin.

Prova di isolamento impianto.

Installation insulation test.

Essai de l’isolement de l’installation.

Prueba de aislamiento ed la instalación

Plant isolatietest

Teste de isolamento da instalação 

Tesisatın yalıtım testi.

Содержание T734F100EBD

Страница 1: ...35 Y 35 35 140 127 165 X 93 112 2 Nm 3 Nm ø3 65 ø4 2 86 max 6 7 17 5 35 100 86 E E E E X Y 2 RESET OFF ON PUSH TO TRIP E D E 94 01 21 01 GF LE12624AA BTicino SpA Viale Borri 231 21100 Varese Italy www bticino com M3 250 ELE RCD LE12624AA ...

Страница 2: ...rijgave 8 Aardlek TEST knop 9 Signalerings LED 10 Mechanische selector voor dielectrische test 1 Işlemek 2 Mekanik test butonu 3 Sadece hizmet için 4 Koruma ünitesi ayarları 5 Mühürleme yeri 6 Entegre yardımcı kontak modülü M C I 7 Diferansiyel Serbest Bırakma Göstergesi Kolu 8 Kaçak akımTEST butonu 9 Led li sinyal lambaları 10 Mekanik açtırma dielektrik test seçici 1 Manusear 2 Botão de teste mec...

Страница 3: ... DE PROTECTION AJUSTES DE LA UNIDAD DE PROTECCIÓN PALLEN VOOR HET AANPASSEN VAN DE BESCHERMINGSGROEP CONFIGURAÇÕES DA UNIDADE DE PROTEÇÃO KORUMA ÜNITESI AYARLARI Impostazioni di fabbrica I n A 0 03 t s 0 Factory setting I n A 0 03 t s 0 Réglages par d usine I n A 0 03 t s 0 Ajustes de fábrica I n A 0 03 t s 0 Fabrieksinstelling I n A 0 03 t s 0 Configurações de fábrica I n A 0 03 t s 0 Fabrika aya...

Страница 4: ...te Knipperende rode led LED vermelho piscando Kırmızı Led yanıp sönüyor ALARM I 60 i n 4 PRE ALARM ON ALARM Led Rosso acceso Red led on LED rouge allumée Led Rojo encendido Rode LED aan LED vermelho aceso Kırmızı Led sabit yanıyor PRE ALARM I 45 i n 5 PRE ALARM ON ALARM Led Verde acceso Green led on LED verte allumée Led Verde encendido Groene LED aan LED verde aceso Yeşil Led sabit yanıyor Auto a...

Страница 5: ...tact 112 Normal close contact 114 Normal open contact TRIP RCD EC TR 191 Common contact 194 Normal open contact ST A UVR Max n 3 cables 1 mm2 AWG 17 Max n 8 cables 0 34 mm2 AWG 22 Max n 4 cables 0 5 mm2 AWG 20 Max n 3 cables 1 mm2 AWG 17 Max n 6 cables 1 mm2 AWG 17 Max n 8 cables 0 5 mm2 AWG 20 Max n 8 cables 0 34 mm2 AWG 22 Max n 4 cables 0 5 mm2 AWG 20 Max n 8 cables 0 34 mm2 AWG 22 10 max 1 O I...

Страница 6: ...lectronique connecté Posición de bloqueo en abierto con el circuíto electrónico conectado Gesloten open positie met aangesloten elektronisch circuit Posição aberto bloqueado com circuito electrónico ligado AÇIK konumda kilitleme elektronik devre çalışır Posizione di test dielettrico apparecchio bloccato in aperto circuito elettronico sezionato Dielectric test postion OPEN device electronic circuit...

Страница 7: ...blok Esquema interno de aparelho magnetotérmico com diferencial integrado Dahili kaçak akım modüllü termik manyetik şalterin iç bağlantı şeması Prova d intervento differenziale Test of residual current tripping Essai de déclenchement différentiel Prueba de disparo diferencial Testvandifferentieelstroom afschakeling Teste de disparo diferencial Artık akımla açmanın testi Ripetere questa prova frequ...

Страница 8: ...andığında açma eğris I tempi di sgancio quando il tempo di non intervento è regolato su 0 3s 1s 3s sono conformi al seguente grafico Tripping curves when time delay is settled on 0 3s 1s 3s Lorsque le délai de non déclenchement a été réglé sur 0 3s 1s et 3s les temps de déclenchement sont conformes au graphique suivant Cuando el tiempo de no desconexión se ha ajustado a 0 3s 1s 3s los tiempos de d...

Страница 9: ... las instrucciones tener en cuenta el lugar de montaje específico del producto No abrir desmontar alterar o modificar el aparato salvo que esto se indique específicamente en las instrucciones Todos los productos BTicino deben ser abiertos y reparados exclusivamente por personal formado y habilitado por BTicino Cualquier apertura o reparación no autorizada anula la totalidad de las responsabilidade...

Страница 10: ...10 ...

Страница 11: ...11 ...

Страница 12: ...12 ...

Отзывы: