background image

9

ST-00000695-

BUS

BUS

BUS

ON

ON

ON

346841

344682

344682

344682

346841

344682

344682

344682

344682

17/03/2020

EN

Classe100 X16E  2 WIRES / Wi-Fi handsfree 

video internal unit with inductive loop

Wiring diagrams

Below are some examples of connection of the CLASSE 300X13E (344642 ‑ 344643) video handset in multi‑family 2 wire video door entry systems.

DIAGRAM 1 - EXAMPLE OF MULTI-FAMILY SYSTEM

APARTMENT 1

RISER

APARTMENT 2

APARTMENT 3

Note:
• for the sizing of the system, refer to the table of page 8.

General notes:
• it is recommended that the Classe100 X16E is installed near the Wi-Fi router.
• the best performance levels can be achieved by installing one single Classe100 X16E for each Wi-Fi network (SSID).
• it is possible to install just one Classe100 X16E for each apartment.
• Classe100 X16E must be installed only in systems completely made with 2 wires technology.

Содержание 344682

Страница 1: ...s that allow the door lock release the entrance panel activation scrolling the staircase light control and the customisation of most frequently used quick actions e g intercom additional door lock activation generic activations The device has a side lever to adjust colour brightness and display contrast audio volume call tone volume andWi Fi configuration There are call exclusion notification LEDs...

Страница 2: ...s and programming Configuration The device must be only physically configured N internal unit number The configurators connected to the N sockets of the device assign an identification number within the system to each video internal unit The internal units must be configured in progressiveorder Internalunitswithparallelconnection max3areallowedinsideapartmentswithoutitem346850 mustbeconfiguredusin...

Страница 3: ... 346230 346260 configured with P 2 M 20 Key functions described above Professional studio M 40 Key functions described above Pager M 80 Key functions described above Professional studio Pager M 01 Internal intercom It sends the call to all the handsets with the same address Intercom inside the apartment in systems with apartment interface 346850 or intercom among apartments in systems without apar...

Страница 4: ...stems without apartment interface N 1 N 2 N 2 N 3 N 3 N 2 EP door lock release configured with P 1 directly without call or activation of the actuator 346210 configured with P 1 and MOD 5 or activation of door lock actuators 346230 346260 configured with P 1 EP door lock release configured with P 2 directly without call or activation of the actuator 346210 configured with P 2 and MOD 5 or activati...

Страница 5: ...ong apartments in systems without apartment interface N 1 N 2 N 2 N 5 N 3 N 2 N 4 N 2 N 5 N 2 Intercom inside the apartment in systems with apartment interface 346850 or intercom among apartments in systems without apartment interface N 1 N 3 N 2 N 3 N 3 N 5 N 4 N 3 N 5 N 3 Intercom inside the apartment in systems with apartment interface 346850 or intercom among apartments in systems without apar...

Страница 6: ...nal studio M 44 Key functions described above Pager M 84 Key functions described above Professional studio Pager M 05 EP door lock release configured with P 1 directly without call or activation of the actuator 346210 configured with P 1 and MOD 5 or activation of door lock actuators 346230 346260 configured with P 1 EP door lock release configured with P 2 directly without call or activation of t...

Страница 7: ...tem Activation of the EP configured with P 1 directly without call or activation of the actuator 346210 configured with P 1 and MOD 9 EP door lock release configured with P 1 directly without call or activation of the actuator 346210 configured with P 1 and MOD 5 or activation of door lock actuators 346230 346260 configured with P 1 EP door lock release configured with P 2 directly without call or...

Страница 8: ... 90 m 60 m 18 Classe100 X16E in out 50 m 110 m 70 m 50 m 22 Classe100 X16E in out 50 m 105 m 65 m 45 m 5 Classe100 X16E with shunt 50 m 160 m 95 m 70 m 10 Classe100 X16E with shunt 50 m 120 m 75 m 55 m 16 Classe100 X16E with shunt 50 m 90 m 55 m 35 m MAXIMUM LINE D DISTANCE ENTRANCE PANEL DOOR LOCK Cable section mm2 0 28 mm 2 BTicino cable L4669 0 35 mm2 BTicino cable 336904 0 5 mm2 1 mm 2 S S cla...

Страница 9: ...set in multi family 2 wire video door entry systems DIAGRAM 1 EXAMPLE OF MULTI FAMILY SYSTEM APARTMENT1 RISER APARTMENT 2 APARTMENT 3 Note forthesizingofthesystem refertothetableofpage8 Generalnotes itisrecommendedthattheClasse100X16EisinstalledneartheWi Firouter thebestperformancelevelscanbeachievedbyinstallingonesingleClasse100X16EforeachWi Finetwork SSID itispossibletoinstalljustoneClasse100X16...

Страница 10: ... 344672 344652 344662 344672 344652 344662 344672 344682 344682 344682 17 03 2020 EN Classe100 X16E 2 WIRES Wi Fi handsfree video internal unit with inductive loop Wiring diagrams DIAGRAM 2 EXAMPLE OF MULTI FAMILY SYSTEM WITH ADDITIONAL INTERNAL UNITS Note max3internalunitforapartment forthesizingofthesystem refertothetable ofpage8 APARTMENT 1 RISER APARTMENT 2 APARTMENT 3 ...

Страница 11: ...4672 344652 344662 344672 344652 344662 344672 344652 344662 344672 346050 344652 344662 344672 344652 344662 344672 344652 344662 344672 344652 344662 344672 346050 344652 344662 344672 344652 344662 344672 344652 344662 344672 344652 344662 344672 344682 17 03 2020 EN Classe100 X16E 2 WIRES Wi Fi handsfree video internal unit with inductive loop Wiring diagrams DIAGRAM 3 EXAMPLE OF A MULTI FAMIL...

Страница 12: ...344652 344662 344672 344652 344662 344672 344652 344662 344672 346050 344652 344662 344672 344652 344662 344672 344652 344662 344672 344652 344662 344672 344682 17 03 2020 EN Classe100 X16E 2 WIRES Wi Fi handsfree video internal unit with inductive loop Wiring diagrams DIAGRAM 5 EXAMPLE OF TWO FAMILY DIAGRAM VILLA2 VILLA1 Note max3internalunitsforapartment Note max5internalunitsforapartment DIAGRA...

Страница 13: ...Audio Video connection and settings Settings menu You must use the joystick on the side of the device to navigate on the menu and select the settings SYMBOL ACTIONSTO BE PERFORMED FUNCTION Press Confirm 5 sec Press and hold down for more than 5 sec Access the Adjustments mode Move the joystick up when released it returns to central position Previous page increase level Move the joystick down when ...

Страница 14: ... stand by press the joystick to activate the display You can download the Door Entry CLASSE100X App from the Stores The page disappears after the first association with the App Adjust the ringtone volume Activate deactivate the Professional studio Office function Move the joystick up down to select the page among Wi Fi adjustments and settings WI FI ADJUSTMENTS AND SETTINGS MENU ...

Страница 15: ... Classe100 X16E 2 WIRES Wi Fi handsfree video internal unit with inductive loop Wi Fi settings page where it is possible to enable disable reset theWi Fi perform the first association to the app and reset the device Device info Exit the menu ...

Страница 16: ...o the exclusion of the ringtone The corresponding LED flashes red ACTIVATE DEACTIVATETHE PROFESSIONAL STUDIO OFFICE FUNCTION When a call is received from the entrance panel this function automatically activates the associated door lock without the need for pressing the door lock control key To enable this function Classe100 X16E must be configured as shown in the Configuration Special functions se...

Страница 17: ...k to activate the display and select the corresponding page In this page you can display theWi Fi network to which the device is connected and if necessary disable the connection Note toconnectthedevicetotheWi Finetworkandtotheapp youmust firstassociatetheClasse100X16EtotheDoorEntryCLASSE100Xapp This page can be used to reset theWi Fi network This page can be used to reset the device Exit the menu...

Страница 18: ...nticated to it Note todisconnecttheWi Finetworkfromthedevice thedevicemustbe resetfollowingtheappropriateprocedure Move the joystick down to select the confirmation icon Press the joystick to confirm Now the device is no longer connected to theWi Fi network To reconnect the device to the same network or to a new one you must complete the guided procedure from the Door Entry CLASSE100X app in the S...

Страница 19: ...it with inductive loop Device reset Press the joystick to reset the device Move the joystick down to select the confirmation icon Press the joystick to confirm DEVICE INFO From stand by press the joystick to activate the display and select the corresponding page Press the joystick to display the information Note AllthedataconcerningassociatedaccountsandtheWi Ficonnection willbedeleted ...

Страница 20: ...joystick to modify the parameters The page shows the type of parameter A and the set level B 2 Move the joystick up down to select the type of parameter for which you want to modify the value see the following table ICON TYPE OF PARAMETER Speaker volume Parameter that can be adjusted only with active audio Image brightness Image contrast Image colour 4 Move the joystick up down to select the desir...

Страница 21: ...ternal unit with inductive loop From stand by press and hold down the joystick for about 5 seconds to activate the display and access the Settings menu Enable disable the key sound Associate a ringtone to an event Exit the menu Move the joystick up down to select the page among Settings SETTINGS MENU ...

Страница 22: ...ick for 5 seconds to access the advanced menu and select the corresponding page A Function status notification ON enabled OFF disabled 1 Press the joystick to change mode 2 Move the joystick up down to select another setting or the last page to exit ASSOCIATE A RINGTONETO AN EVENT CALL This page can be used to modify the ringtones associated to the different types of call The ringtones played for ...

Страница 23: ...ice messages using the microphone of the Classe100 X16E through the speakers of the sound system To enable this function Classe100 X16E must be configured as shown in the Configuration Special functions section Function use From stand by PAGING function Broadcast the message Press the right Connection key to end This function notifies the status of the Door lock If open the LED Door lock flashes a...

Страница 24: ...n of a door lock are disabled and when they are pressed the white LED flashes Note it cannot be activated together with the Professional Studio Office function Enabling the function SAFE DOOR LOCK function Move the corresponding microswitch to ON INDUCTIVE LOOP use The inductive loop function enables the device to be used by people wearing hearing aids with T selector Switch the acoustic device to...

Страница 25: ... with the device at this point you can answer a video door entry call from the Entrance Panel CALL HOME call your Classe100 X16E display the images from the entrance panels and cameras open the door lock of the Entrance Panels update the firmware of your Classe100 X16E To use the functions by means of the app refer to the documentation that can be downloaded from the website To download the Door E...

Отзывы: