![background image](http://html1.mh-extra.com/html/bticino/344652/344652_manual_2825163002.webp)
2
ST-00000691-
344652
N
P
M
P
M
N
BUS
ON OFF
Master
Slave
ON
CTS
1
2
BTICINO
V.le Borri, 231
21100 (VA) ITALY
1
2
3
4
5
6
7
17/03/2020
EN
Classe100 V16B handsfree video
internal unit
Configuration
Rear view
Legend
1.
Slave / Master function microswitch
2.
Line termination ON / OFF micro-switch.
ON=
To activate the function with device not powered
3.
Configurator socket
4.
Line termination ON / OFF micro-switch.
5.
2 wires SCS BUS connection clamps.
6.
Clamps for the connection of an external call to the floor pushbutton
P
M
N
BUS
ON OFF
Master
Slave
ON
CTS
1
2
BTICINO
V.le Borri, 231
21100 (VA) ITALY
Made in Italy
7.
Joystick for adjustments and programming
The device must be only physically configured.
N - internal unit number
The configurators connected to the N sockets of the device assign an identification number within the system to each video internal unit. The internal units must be configured in
progressive order. Internal units with parallel connection (max 3 are allowed inside apartments without item 346850) must be configured using the same N configurator. In parallel with
the main video internal unit, additional internal units, video internal units and/or ringtones may be installed.
P – entrance panel association
The configurators connected to the P sockets of the device identify the associated EP, which is the first entrance panel that switches itself on when the pushbutton is pressed the first time,
as well as which door lock is activated when pressing the door lock pushbutton while the video internal unit is idle.
M – operating mode
The configurators connected to the M sockets of the device assign the operating modes to the 3 programmable keys based on the following indications.