4.1.2.1.7 Chlorine/ORP Alarm
When the unit is configured in automatic mode, it is possible to disable the
“
Chloride Alarm
”
. This alarm will detect if the ORP or PPM reading hasn
’
t
changed for two hours or more, despite the unit has been in production.
Despite this alarm is been implemented to detect if a probe is not in good
conditions, or there is some chemical issue in the water, it can be disabled if
the user wants to maintain the production despite everything.
Note: Password
“
1234
”
is required to modify this function.
4.1.2.1.8 Night Alarm (22h-9h)
When an alarm occurs, the unit stops its production and shows an acoustic and
visual alarm to indicate that it’s necessary to correct
the problem.
However, it is possible to keep the alarm silent between 10:00 pm and 9:00
am, selecting the option Night Alarm = N
4.1.2.2- Chorine menu
With this menu you can select all parameters related to chlorine production.
4.1.2.2.1- Chlorine production
Configuration of the maximum production of chlorine.
From 0%
to 100% Press “OK” and use the arrows
to change the value.
Press "OK" to confirm the adjustment.
Note: Chlorine production may be limited regardless of the operation mode
(manual, automatic...) that is selected.