Your Davey Pool Pump
Congratulations on your purchase of a quality product from the Davey range
of Pool and Sp
a Equipment. Y
ou are assured of many years of reliable and
efficient performance from your Davey Power
Ace
®
CR Pool Pump backed
by Davey’s three year guarantee.
Davey Power Ace
®
CR Pool Pumps have been designed to circulate
swimming pool and spa water in conditions set out in the Australian
Standard for swimming pool water quality (AS 3633) or equivalent. They
should not be used for any other purpose without first consulting your Davey
Dealer or Davey Products Pty Ltd.
Davey design and build its own electric motors especially for its pumps. The
matched motor and “pumping end” are designed to provide the quietest
possible operation while delivering maximum water flow.
Davey’s tot
ally enclosed fan-cooled motor incorporates “autostart” overload
protection with a built-in automatic thermostat designed to protect the motor
from overheating.
Every Davey Pool Pump is thoroughly water tested against a number of flow,
pressure, voltage, current and mechanical performance parameters.
Davey’s advanced pump manufacturing technology provides reliable and
efficient pumping performance that last
s and lasts.
INSTALLA
TION INSTRUCTIONS
Location
The pump should be located as close to the water as practicable and
mounted on a firm base in a well drained position, high enough to prevent
any flooding. It is the installer
’s
/ owner’s
responsibility to locate the pump
such that the nameplate can be easily read and it can be readily accessed
for service.
Where pumps and/or associated accessories have been installed by
authorised Davey Dealers or installers, end users should seek advice from
the original dealer/installer before making any site changes.
Weather Protection
It is recommended that the pump is protected from the weather. Enclosures
should be ventilated to prevent condensation built-up and allow a free flow of
air for the fan cooled motor.
– 3 –
Power Connection
Davey Power Ace
®
CR Pool Pumps are suitable for connection to a nominal 240
volt 50Hz power supply and are equipped with a flex and 3 pin plug. If a power
outlet is not available within 3 metres of the pump, a 3 pin power point in a safe,
dry place, may need to be provided by an electrician. Extension cords are unsafe
around pools, and should be avoided. If the supply cord of this product is
damaged it must be replaced with Davey Supply Cord Part No. 43233-2.
Pipe Connections
Suction Piping
A barrel union is provided for connecting to the piping from the pool.
The pumps
are designed to accept 40mm PVC pipe of the ID of the barrel union or 50mm
fittings on the OD of the barrel union. 50mm PVC pipe is required on the suction
side of the PACR300. 25mm or 32mm flexible hose can be used with the
PACR100 with the use of appropriate adaptor/s.
The use of any pipe smaller than
those specified above is not recommended. Suction piping should be free from
all air leaks and any humps and hollows which could cause suction dif
ficulties.
Discharge Piping
A barrel union is supplied for connecting the piping to the filter
. The pump
s are
designed to accept 40mm PVC pipe on the ID of the barrel union or 50mm fittings
on the OD of the barrel union. 25mm or 32mm flexible hose can be used with the
PACR100 with the use of appropriate adaptor/s.
The discharge piping from the
pump outlet should be connected to the inlet connection on the swimming pool
filter (usually at the filter control valve).
The installation of this product should be carried out by a person
knowledgeable in swimming pool plumbing requirements following the
Installation Instructions provided in this manual.
DAVEY PRODUCT GUARANTEE FOR AUSTRALIA & NEW ZEALAND
This Davey product is guaranteed to be free of material or manufacturing defects at the time
of original purchase. Should any part fail as a result of such defects within three years of
original purchase, the product will be repaired free of charge.
TERMS AND CONDITIONS
1. This guarantee applies to all states and territories of Australia and New Zealand only and is
subject to the provisions of the Trade Practices Act (Aust.), the Goods and Consumer
Protection Legislation of the various Australian states and the Consumers Guarantee Act
1993 (NZ) as applicable.
2. The guarantee period commences on the date of original purchase of the equipment.
Evidence of this date of original purchase must be provided when claiming repairs under
guarantee. It is recommended you retain all receipts in a safe place.
3. This guarantee covers parts and workshop labour only. Goods should be forwarded, with
proof of date of original purchase, to an Authorised Davey Service Centre freight paid. Any
travel and removal/reinstalling charges for goods repaired infield will be to the owners
account. Guarantee may be denied on goods not readily accessible for service personnel
or mounted on exterior walls above single storey level.
4. This guarantee is subject to due compliance by the original purchaser with all directions
and conditions set out in the Installation and Operating Instructions. Failure to comply
with these instructions, damage or breakdown caused by fair wear and tear, negligence,
misuse, incorrect installation, chemical or additives in the water, inadequate protection
against freezing, rain or other adverse weather conditions, corrosive or abrasive water,
lightning or high voltage spikes or through unauthorised persons attempting repairs are
not covered under guarantee. The product must only be connected to the voltage shown
on the nameplate.
5. Without limiting the original purchaser’s entitlements under the Trade Practices Act (Aust.),
the Goods & Consumer Protection Legislation of the various Australian states, or the
Consumers Guarantee Act 1993 (NZ), Davey shall not be liable for any loss of profits or any
consequential, indirect or special loss, damage or injury of any kind whatsoever arising
directly or indirectly from the product or any defect.
6. Where the Trade Practices Act (Aust.), the Goods and Consumer Protection Legislation of
the various Australian states and the Consumers Guarantee Act 1993 (NZ) does not apply,
Davey shall not be liable for any loss of profits or any consequential, indirect or special loss,
damage or injury of any kind whatsoever suffered by the purchaser arising directly or
indirectly from the product or any defect and the purchaser shall indemnify Davey against
any claim by any other person whatsoever in respect of any such loss, damage or injury.
7. Nothing in this guarantee is intended to have the effect of contracting out of the provisions
of the Trade Practices Act (Aust.), the Goods and Consumer Protection Legislation of the
various Australian states and Consumers Guarantee Act 1993 (NZ) except to the extent
permitted by the various Acts, and this guarantee is to be modified to the extent necessary
to give effect to that intention.
8. Davey may be collecting personal information from you in order to provide you with a
service. Davey Pumps Pty Ltd promises only to use this information in accordance with the
Provisions of the Privacy Act 1988 (Cth) and the Privacy Policy of Davey Pumps Pty Ltd
which is available at www.davey.com.au.
®
Daveyand Power Ace are registered trademarks of Davey Products Pty Ltd.
©
Davey Products Pty Ltd 2000
In the interests of safety
, we advise that all brands and types of pool
pumps must be installed in accordance with AS3000 wiring rules or
equivalent. Davey Power Ace
®
CR Pool Pumps are supplied with a fixing
point to enable easy earthing / equipotential bonding when required.
Barrel unions need to be hand tightened only. No sealant, glues or
silicones are needed.
If the pump and filter are located below pool water level, it is necessary
to fit isolating valves in the pipe between the pump and the skimmer
box and in the return pipe from the filter to the pool.
The fittings on this product are constructed of ABS. Some PVC jointing
compounds are incompatible with ABS. Check compound suitability
before use.
NOTE:
Power Ace
®
CR Pool Pumps are fitted with an internal check valve to
prevent the reverse flow of water through the pump.
Davey Products recommends that all installations are fitted with earth
leakage or residual current protection devices.
Warning! Ensure that an electrical isolation switch is located with easy
access so that the pump can be switched off in an emergency.
Davey Products Pty Ltd
Member of the GUD Holdings Ltd Group
ABN 18 066 327 517
Head Office and Manufacturing
6 Lakeview Drive,
Scoresby, Australia 3179
Ph:
+61 3 9730 9222
Fax:
+61 3 9753 4100
Website: www.davey.com.au
Customer Service Centre
Ph:
1300 367 866
Fax:
1300 369 119
E-mail: [email protected]
Interstate Offices
Sydney – Brisbane – Adelaide
Perth - Townsville
International
6 Lakeview Drive,
Scoresby, Australia 3179
Ph:
+61 3 9730 9121
Fax:
+61 3 9753 4248
E-mail: [email protected]
Germany
Kantstrasse 47,
04275 Leipzig
Ph:
+49 341 301 0412
Fax:
+49 341 301 0413
E-mail: [email protected]
New Zealand
220A Bush Road,
North Harbour, Auckland 1330
Ph:
+64 9 914 3680
Fax:
+64 9 914 3685
Website: www.daveynz.co.nz
E-mail: [email protected]
U.S.A.
1005 N. Commons Drive
Aurora, Illinois 60504
Ph:
+1 630 898 6976
Fax:
+1 630 851 7744
Website: www.daveyusa.com
E-mail: [email protected]