B
Appendix 2 - Saving Parameters and Loading Firmware
98/108
CLS Pro 600 – Line and Contrast Sensor
B
Appendix 2 - Saving Parameters and Loading Firmware
B1
Save Parameters
System configurations and saved jobs can be backed-up and saved
on an external medium (a PC running MS Windows).
Use the sensor’s USB interface to transfer the data.
Procedure:
1. Unscrew the stop from the sensor enclosure that is fitted in
front of the USB interface ① and then find the button ② that
activates the memory function.
2. Use a mini USB cable ③ to connect the sensor up to a PC or a
laptop.
3. Activate the sensor’s memory function. In this case you must
press the function activation button ④. The sensor will now
be seen as another PC / laptop drive ⑤.
4. Copy the required data from the
settings
⑥ directory into a
directory that you previously created for this purpose in the
PC / laptop.
5. Call up the
Safely remove hardware
function from the task-bar
after you have saved the data and then cancel the connection.
6. Disconnect the cable afterwards and then screw the stop back
into the sensor enclosure.
7. Now run a sensor restart (mains OFF / ON).
B2
Loading Firmware
If the sensor or control panel firmware has been modified then
the firmware must be loaded separately for both devices. Use the
control panel and sensor USB interfaces to load the firmware up-
dates.