41
16.0
Recall Screen
Pressing the RECALL button when no blue EDIT LEDs are illuminated will
cause the recall screen to be displayed, with the program number PICK item
highlighted.
The parameter wheel may then be turned to select an alternative program
number from which to recall the new parameters. As the parameter wheel is
turned, a highlight bar will move through the program list, highlighting the
name of the selected program location. The first row of names on each page
also shows the OEM name of the stored programs.
Top Soft Key
PICK
Middle Soft Key
TYPE
The middle soft button will select the TYPE of program or file, which may be
adjusted by the parameter wheel from the default INTernal setting to either of
the PCMCIA memory card settings; CPrg to recall a single program, or CAll to
set the entire contents of the internal memory to a new set-up, including all
programs, from a PCMCIA memory card.
Recall Screen
A second press on the RECALL button will now set the current parameters to
that of the program. If an attempt is made to recall from a blank location,
recall is inhibited, and a warning message is displayed. If any of the level TRIM
controls are non-zero, the user will be invited to centralise them.
To escape from the recall process at any time, press the EDIT button.