![BSR BSR00034 Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/bsr/bsr00034/bsr00034_reference-manual_2823517044.webp)
DS4800 REFERENCE MANUAL
30
2
2.6 SUBZERO TEMPERATURE MODELS
The DS4800 Subzero scanner is an industrial scanner designed to operate in industrial
refrigerator/freezer cells or other stable subzero degree environments, which are below the
operating range of standard industrial scanners. It is not designed to move between subzero
and normal environments (rapid temperature changes).
The DS4800 Subzero has an intelligent microprocessor-driven and efficient internal heating
system which constantly monitors and automatically controls internal temperature. Only the
necessary temperature-sensitive components are heated, resulting in an efficient heating
system which has very low power consumption. Part of this system also heats the Laser
Beam Output window to eliminate ice and/or condensation build-up from negatively affecting
the reading results.
Upon power-up in a subzero environment, the scanner waits until these internal components
are heated to within their operating temperature range. Power-up at -35 °C can take about 20
minutes before the scanner is ready to read barcodes. During this time the laser, motor, and
display remain off and the Ready LED blinks, indicating the warm-up phase. While in the
warm-up phase, scanner communication is operative and the device can be configured
through Genius™ or through Host Mode Programming.
In
te
rn
al T
emp
erature
(°C)
20
Scanner Normal Operation
Starting Point
Stabilized Temperature Phase
Warm-Up
Phase
Cold Start
0
Time (min)
-35
0
The DS4800 Subzero can be connected to the CBX100 LT Subzero connection box which
can withstand the same low temperature environment as the scanner. A CBX100 LT all-in-
one model includes a BM100 backup and restore module having an extended temperature
range also for use in subzero environments.
2.7 MODEL DESCRIPTION
The DS4800 scanner is available in versions that differ in regard to the following parameters:
Optical Model
Special Features
DS4800 - 1 X 0 X
Optical Model
0 = Standard
1 = Oscillating Mirror
Special Features
0 = Standard
5 = Heater (Subzero Temp)
Содержание BSR00034
Страница 1: ...DS4800 Reference Manual BSR idware GmbH Jakob Haringer Str 3 A 5020 Salzburg Web www bsr at...
Страница 5: ...v INDEX 115...
Страница 27: ...RAPID CONFIGURATION 13 1 b Operating mode selection and definition c Digital Outputs configuration...
Страница 51: ...INSTALLATION 37 3 Figure 20 Positioning with U Shape Mounting Bracket Pitch Skew 0 15 45 45 15 alignment marks...
Страница 63: ...CBX ELECTRICAL CONNECTIONS 49 4 Figure 33 ID NET Network Connections with isolated power blocks...
Страница 64: ...DS4800 REFERENCE MANUAL 50 4 Figure 34 ID NET Network Connections with Common Power Branch Network...
Страница 65: ...CBX ELECTRICAL CONNECTIONS 51 4 Figure 35 ID NET Network Connections with Common Power Star Network...
Страница 78: ...DS4800 REFERENCE MANUAL 64 5 Figure 55 DS4800 Multidrop Connection to a Multiplexer...
Страница 81: ...25 PIN CABLE ELECTRICAL CONNECTIONS 67 5 Figure 57 ID NET Network Connections with isolated power blocks...
Страница 82: ...DS4800 REFERENCE MANUAL 68 5 Figure 58 ID NET Network Connections with Common Power Branch Network...
Страница 83: ...25 PIN CABLE ELECTRICAL CONNECTIONS 69 5 Figure 59 ID NET Network Connections with Common Power Star Network...
Страница 133: ...www automation datalogic com...