CBX ELECTRICAL CONNECTIONS
57
4
OUTPUT CONNECTIONS USING DS4800 POWER
Power to
Output
Output device
Signal
Output device
Reference
Output Device
Figure 44 - Open Emitter Output Using DS4800 Power
Power to
Output device
Output device
Reference
Output Device
Output
Signal
Figure 45 - Open Collector Output Using DS4800 Power
OUTPUT CONNECTIONS USING EXTERNAL POWER
Pulled up to External
Output Device Power
Output
Signal
Output Device
Figure 46 - Open Emitter Output Using External Power
Pulled down to External
Output Device Reference
Output
Signal
Output Device
Figure 47 - Open Collector Output Using External Power
V
CE
max = 30 Vdc
I max = 40 mA continuous; 130 mA pulsed
Содержание BSR00034
Страница 1: ...DS4800 Reference Manual BSR idware GmbH Jakob Haringer Str 3 A 5020 Salzburg Web www bsr at...
Страница 5: ...v INDEX 115...
Страница 27: ...RAPID CONFIGURATION 13 1 b Operating mode selection and definition c Digital Outputs configuration...
Страница 51: ...INSTALLATION 37 3 Figure 20 Positioning with U Shape Mounting Bracket Pitch Skew 0 15 45 45 15 alignment marks...
Страница 63: ...CBX ELECTRICAL CONNECTIONS 49 4 Figure 33 ID NET Network Connections with isolated power blocks...
Страница 64: ...DS4800 REFERENCE MANUAL 50 4 Figure 34 ID NET Network Connections with Common Power Branch Network...
Страница 65: ...CBX ELECTRICAL CONNECTIONS 51 4 Figure 35 ID NET Network Connections with Common Power Star Network...
Страница 78: ...DS4800 REFERENCE MANUAL 64 5 Figure 55 DS4800 Multidrop Connection to a Multiplexer...
Страница 81: ...25 PIN CABLE ELECTRICAL CONNECTIONS 67 5 Figure 57 ID NET Network Connections with isolated power blocks...
Страница 82: ...DS4800 REFERENCE MANUAL 68 5 Figure 58 ID NET Network Connections with Common Power Branch Network...
Страница 83: ...25 PIN CABLE ELECTRICAL CONNECTIONS 69 5 Figure 59 ID NET Network Connections with Common Power Star Network...
Страница 133: ...www automation datalogic com...