4
•
Operating Temperature: 0 to 40° C
•
Storage Temperature: -25 to 85°C
•
Operating Humidity Range: 0 to 90% RH
•
Cooling: By FAN forced air
TECHNICAL SPECIFICATIONS:
CHARGING INSTRUCTIONS:
STEP 1 - Pre Charge Check & Electrolyte Level Check
•
Check the Battery Electrolyte level (Not required on Sealed & Maintenance Free Batteries).
If necessary, remove the vent caps and add distilled water so the levels are halfway between the
upper and lower fill lines.
STEP 2 - Connecting the Bank Charger to your Battery
•
If the Battery is out of the vehicle:
o
Connect the Red lead from the charger to the positive (+) battery terminal.
o
Connect the Black lead from the charger to the negative (-) battery terminal.
STEP 3 - Connect the Bank Charger to Mains Power
•
Connect the battery charger to a Mains Powered socket.
•
Turn on the Mains Power.
•
The Charger will automatically start when AC power is connected and switched on.
Part Number
BK10
Type
Automatic
Input Voltage Range
100
-
240V
Input Frequency
50/60Hz
Output
1A @ 12V
Size (L*W*H) in
mm
401*151*73
Weight
Approvals
3.6 Kg
CE, Mzs, As