8
Temperature function (Twin Display Models only)
Be sure to insert the banana plug type-K temperature bead probe Bkp60 with correct
polarities. Slide-switch on defaults at degree C (Celsius). Press
SELECT
button
momentarily to select degree F (Fahrenheit). You can also use a plug adapter Bkb32
(Optional purchase) with banana pins to type-K socket to adapt other type-K standard
mini plug temperature probes.
µ
µ
µ
µ
A Current function (Twin Display Models only)
Inputs are made through the test leads terminals. Slide-switch on defaults at DC. Press
SELECT button momentarily to select AC.
Application notes:
The DC
µ
A function is designed especially for HVAC/R flame sensor applications. The
0.1
µ
A resolution is useful for identifying the minute current changes in flame detector