14
Ohms
RANGE
Accuracy
400.0
Ω
0.8% + 8d
4.000k
Ω
, 40.00k
Ω
,
400.0k
Ω
0.6% + 4d
4.000M
Ω
1.0% + 4d
40.00M
Ω
2.0% + 4d
Open Circuit Voltage : 0.4VDC typical
Audible Continuity Tester
Audible threshold : between 5
Ω
and
120
Ω
.
Diode Tester
Open Circuit Voltage
Test Current
(Typical)
< 1.6 VDC
0.25mA
Hz Frequency
Function
Sensitivity
(Sine RMS)
Range
400.0mV
350mV
10Hz
~
2kHz
4.000V
1V
10Hz
~
5kHz
4.000V,
40.00V
32V
10Hz
~
100kHz
400.0V
100V
10Hz
~
10kHz
600V
500V
10Hz
~
5kHz
400.0
µ
A
1)
500
µ
A
10Hz
~
30kHz
2000
µ
A
1)
500
µ
A
10Hz
~
30kHz
400.0A
2) 3)
60A
40Hz
~
400Hz
Display counts: 5000
Best resolution: 0.001Hz
Accuracy: 0.5%+4d
1)
Available to Models 127M & 128M only
2)
Available to Models 111M & 112M only
3)
Unspecified for Model 110M
Capacitance*
RANGE
1)
Accuracy
2) 3)
500.0nF, 5.000
µ
F,
50.00
µ
F, 500.0
µ
F,
3000
µ
F
3.5% + 6d
*Not available to Model 110M
1)
Additional 50.00nF range accuracy is
not specified
2)
Accuracies with film capacitor or better
3)
Specified with battery voltage above
2.8V (approximately half full battery).
Accuracy decreases gradually to 12% at
low battery warning voltage of
approximately 2.4V
DC
µ
µ
µ
µ
A (Models 127M & 128M only)
RANGE
Accuracy
Burden
Voltage
400.0
µ
A
2.0% + 4d
2.8mV/
µ
A
2000
µ
A
1.2% + 3d
2.8mV/
µ
A
AC
µ
µ
µ
µ
A (Models 127M & 128M only)
RANGE
Accuracy
Burden
Voltage
50Hz ~ 500Hz
400.0
µ
A
2.0% + 5d
2.8mV/
µ
A
2000
µ
A
1.5% + 5d
2.8mV/
µ
A
Type-K Temperature (Models 127M &
128M only)
RANGE
Accuracy
-20
o
C ~ 300
o
C
2% + 3
o
C
301
o
C ~ 537
o
C
3%
+ 3
o
C
-4
o
F ~ 572
o
F
2% + 6
o
F
573
o
F ~ 999
o
F
3%
+ 6
o
F
Type-K thermocouple range & accuracy
not included