background image

8

To install the thermostat:

1. Gently separate the backplate from the thermostat.
2. Place the thermostat backplate on the wall. Make sure that any ex-

isting wires can be inserted through the opening on the backplate.

3. Using the backplate as a template, mark the location of the mount-

ing holes on the wall as shown below.

Y

N/C

W

O/B

G

RC

RH

C

Y2

W2

AUX

A13338

Fig. 1 -- The solid color indicates mounting holes

4. Move the backplate out of the way and make holes where indicat-

ed in Step 3. The mounting holes can accommodate a #6 pan--

head screw. It is recommended to use the included fasteners to en-
sure proper fitting of the front housing.

5. Use the included drywall plugs (or other suitable anchors) to en-

sure the thermostat can be mounted securely to the wall.

6. Fasten the backplate to the wall using the screws provided (or oth-

er suitable screws).

Содержание T2--WHS01

Страница 1: ...Installation Instructions T2 WHS01 Legacy Line Wi Fir Thermostat NOTE Read the entire instruction manual before starting the installation...

Страница 2: ......

Страница 3: ...p 1 Power Off HVAC Equipment 7 Step 2 Remove Existing Thermostat 7 Step 3 Install the Thermostat 7 Step 4 Connect the Wiring 9 Step 5 Power On the HVAC Equipment 19 NAVIGATING THE MENUS 20 CONFIGURING...

Страница 4: ...low all warnings and cautions included in literature and attached to the unit Consult local building codes and the current edition of the National Electrical Code NEC NFPA 70 In Canada refer to the cu...

Страница 5: ...gacy Line Wi Fi Thermostat is designed to be mounted on the homeowner s wall in a convenient location A13336 PERSONAL INJURY HAZARD Disconnect electric power to the HVAC system before installing this...

Страница 6: ...y Line Wi Fi Thermostat supports d Up to 2 heat and 2 cool stages on a conventional system d Up to 3 heat and 2 cool stages on a heat pump system The Legacy Line Wi Fi Thermostat supports the followin...

Страница 7: ...cations However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be dete...

Страница 8: ...C by default adjustable from 50 to 90 F 10 to 32 C Display 40 to 100 F 5 to 37 C Sensitivity 1 F 0 5 C Operating 32 to 130 F 0 to 55 C Humidity Range Display 20 to 90 R H Sensitivity 5 R H Operating...

Страница 9: ...l Description Voltage Current Max N C Unused N A N A Y 1st Stage Compressor 24V AC 2A W O B 1st Stage Heating or Reversing Valve Changeover 24V AC 2A G Fan 24V AC 2A C Common 24V AC 2A Y2 2nd Stage Co...

Страница 10: ...ning equipment Step 2 Remove Existing Thermostat Disconnect the wires to the existing thermostat and remove it from the wall Step 3 Install the Legacy Line Wi Fi Thermostat The ideal location for the...

Страница 11: ...N C W O B G RC RH C Y2 W2 AUX A13338 Fig 1 The solid color indicates mounting holes 4 Move the backplate out of the way and make holes where indicat ed in Step 3 The mounting holes can accommodate a 6...

Страница 12: ...ween R H and R C Ensure any unused wires do not have exposed bare copper conductors To connect the thermostat to the equipment 1 Connect the wires as shown in the wiring diagrams 2 Attach the The Lega...

Страница 13: ...10 Y N C W O B G RC RH C Y2 W2 AUX 1 stage AC C 24V Y G R W C HUM 1 stage Furnace A13339 Fig 2 Single Stage Heat Cool...

Страница 14: ...11 2 stage AC Y2 R C Y1 Y G R W C HUM 1 stage Furnace Y N C W O B G RC RH C Y2 W2 AUX Y2 Y2 HUM connections on furnace may not be available A13340 Fig 3 Single Stage Heat Dual Stage Cool...

Страница 15: ...12 Y N C W O B G RC RH C Y2 W2 AUX Y1 G W2 W1 HUM C R Y2 2 stage Furnace 1 stage AC C 24V A13341 Fig 4 Dual Stage Heat Single Stage Cool...

Страница 16: ...13 Y N C W O B G RC RH C Y2 W2 AUX Y1 G W2 W1 HUM C R Y2 2 stage Furnace 2 stage AC Y2 R C Y1 A13342 Fig 5 Dual Stage Heat Dual Stage Cool...

Страница 17: ...14 Y N C W O B G RC RH C Y2 W2 AUX O W Y Y2 C G R Fan Coil 1 stage Heat Pump W2 R Y C O A13343 Fig 6 Single Stage Heat Pump with Auxiliary Heat...

Страница 18: ...15 Y N C W O B G RC RH C Y2 W2 AUX O W Y1 C G R Fan Coil 2 stage Heat Pump W2 Y1 R Y2 C O Y2 Y2 connection on fan coil may not be available A13344 Fig 7 Dual Stage Heat Pump with Auxiliary Heat...

Страница 19: ...B G RC RH C Y2 W2 AUX 1 stage AC C 24V Boiler C R W Y1 R C Y2 G Fan Coil Remove RH RC factory jumper C terminal to be connected to heating transformer common A13345 Fig 8 Boiler with Fan Coil and Sing...

Страница 20: ...Y2 W2 AUX 1 stage AC C 24V 2 stage Boiler C W2 R W1 Y1 R C Y2 G Fan Coil Remove RH RC factory jumper C terminal to be connected to heating transformer common A13346 Fig 9 Dual Stage Boiler with Fan Co...

Страница 21: ...RH C Y2 W2 AUX 2 stage AC C Boiler C W R Y1 R R C Y2 Y1 Y2 G Fan Coil Remove RH RC factory jumper C terminal to be connected to heating transformer common A13347 Fig 10 Single Stage Boiler with Fan C...

Страница 22: ...l to be connected to heating transformer common A13348 Fig 11 Dual Stage Boiler with Fan Coil Dual Stage Cool Step 5 Power On HVAC Equipment After you ve completed the wiring you can apply power to th...

Страница 23: ...the temperature set point by 1 F 0 5 C For menus press Y to move up d B down On the Home screen press B to decrease the tempera ture set point by 1 F 0 5 C For menus press B to move down d A left On t...

Страница 24: ...us screen BACK A13358 On Screen Keyboard If you need to type in any information an on screen keyboard will appear To enter a letter or number move to the character by pressing the arrow keys and then...

Страница 25: ...thermal heat pump This helps the thermostat determine optimum perfor mance and default settings If you select No the system will opti mize the settings for an air to air heat pump d OB energize on coo...

Страница 26: ...eat pump evaporator coil is upstream from the source of auxiliary heat This setting is only available when the Comp to Aux Temp Delta and Comp to Aux Runtime settings are both set to Auto default Furn...

Страница 27: ...as a system mode Heat Cool Min Delta The minimum difference between the heat mode set temperature and the cool mode set temperature when the system mode is in auto change over The delta is adjustable...

Страница 28: ...ustable from 0 to 3 F 17 5 to 26 5 C in 0 5 F 0 3 C increments d Heat Dissipation Time The amount of time the fan will run after the heat set point has been reached and the call for heat has been turn...

Страница 29: ...et point is met d Stage 2 Temp Delta The minimum difference between the cur rent temperature and the set temperature that will activate the auxiliary heat regardless if the maximum run time of the pre...

Страница 30: ...a 4 digit installer code This code is pre programmed to 3262 Test Equipment These options let you test the wiring and connections of the devices connected to the thermostat by turning them on or off...

Страница 31: ...nstead To reset the Legacy Line Wi Fi Thermostat From the Home screen press MENU Select Settings Reset Select HVAC Equipment Settings Select Yes Performing a Hardware Reset In rare circumstances stati...

Страница 32: ...creen If homeowners register their thermostats the reminders will be emailed to them and be displayed on the Web Portal You can set the Last Service date turn the Reminder On or Off and set the Freque...

Страница 33: ...generated d Set temperature range of 35 to 68 F 1 5 to 20 C High Temp Alert Sets the temperature at which the thermostat will generate a High Temperature Alert The range can be d Off no alert will be...

Страница 34: ...High Temp Alert Temperature in the home is too high Heat Not Responding The system has failed to heat the home Cool Not Responding The system has failed to cool the home Maintenance Reminder HVAC syst...

Страница 35: ......

Страница 36: ...ant Heating Cooling Systems 7310 W Morris St Indianapolis IN 46231 Edition Date 11 13 Manufacturer reserves the right to change at any time specifications and designs without notice and without obliga...

Отзывы: