—24—
DETAILED COOLING CAPACITIES* Continued
See notes on page 26.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES
°
F
85
95
105
115
CFM
EWB
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Total
Sens‡
Total
Sens‡
Total
Sens‡
Total
Sens‡
697C042-B Outdoor Section With FK4CNF005 Indoor Section Continued
1103
72
46.2
23.3
3.06
44.1
22.5
3.40
42.1
21.8
3.7
40.2
21.1
4.19
67
42.5
29.4
3.03
40.5
28.6
3.36
38.7
27.9
3.7
37.0
27.2
4.14
63††
39.7
28.7
3.00
38.1
28.0
3.34
36.5
27.3
3.7
34.4
26.4
4.10
62
39.3
35.5
3.00
37.5
34.7
3.33
35.7
33.8
3.6
33.9
32.9
4.09
57
37.8
37.8
2.99
36.6
36.6
3.32
35.3
35.3
3.6
33.7
33.7
4.09
1225
72
46.7
24.1
3.09
44.5
23.4
3.43
42.6
22.7
3.8
40.6
22.0
4.22
67
43.0
30.9
3.06
41.0
30.1
3.39
39.2
29.4
3.7
37.5
28.7
4.17
63††
40.3
30.1
3.03
38.6
29.4
3.37
37.0
28.7
3.7
34.8
27.7
4.13
62
40.0
37.6
3.03
38.2
36.7
3.36
36.4
35.7
3.7
34.6
34.6
4.13
57
39.0
39.0
3.02
37.7
37.7
3.36
36.4
36.4
3.7
34.6
34.6
4.13
1409
72
47.4
25.4
3.13
45.1
24.7
3.47
43.1
24.0
3.8
41.1
23.3
4.26
67
43.7
33.1
3.10
41.9
32.4
3.44
39.8
31.6
3.8
37.9
30.8
4.21
63††
40.9
32.2
3.07
39.3
31.4
3.41
37.5
30.7
3.7
35.3
29.7
4.17
62
40.9
40.3
3.08
39.1
39.1
3.41
37.5
37.5
3.7
35.8
35.8
4.18
57
40.6
40.6
3.07
39.2
39.2
3.41
37.7
37.7
3.7
35.8
35.8
4.18
Multipliers for Determining the Performance With Other Indoor Section
s
Indoor
Section
Size
Cooling
Indoor
Section
Size
Cooling
Capacity
Power
Capacity
Power
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CD3(A,B)A
048
0.96
1.03
CJ5A/CK5A/CK5BA
042
0.96
1.03
CD5A/CD5BA
048
0.96
1.03
CJ5A/CK5A/CK5BW
048
0.98
1.02
CJ5A/CK5A/CK5BA
042
0.96
1.03
CK3BA
042
0.96
1.03
048
0.98
1.02
048
0.98
1.02
CK3BA
042
0.96
1.03
—
—
—
048
0.98
1.02