—2—
DIMENSIONS
A94148
ACCESS
PANEL
1
1
/
4
"
1.
Allow 30 in.
clearance to service end of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side,
and 24 in. between units for proper airflow.
Minimum outdoor operating ambient in cooling mode is 55
°
F (unless low ambient control is used) max 125
°
F.
2.
Maximum outdoor operating ambient in heating mode is 66
°
F.
3.
Series designation is the 14th position of the unit model number.
4.
Center of gravity .
5.
NOTES:
AIR DISCHARGE
AIR DISCHARGE
AIR IN
AIR IN
AIR IN
2
1
/
2
"
AIR DISCHARGE
1
3
/
4
"
4
"
3
/8 IN.
DIA LIQUID
LINE CONN
H
DIA SUCTION
LINE CONN
8
3
/
16
"
7
/8 IN.
DIA HOLE
FIELD POWER SUPPLY CONN
7
/
8
IN.
DIA (22.22)
HOLE WITH 1
1
/
8
IN.
DIA (34.92) KNOCKOUT
AND 1
3
/
8
IN.
DIA KNOCKOUT
3
/
8
IN.
DIA (9.5) TIEDOWN KNOCKOUTS
(2) PLACES IN BASEPAN
10
1
/
2
"
FIELD CONTROL
SUPPLY CONN
1
9
/
16
"
L
C
F
N
G
A
B
M
K
E
D
C L
DIMENSIONS (IN.)
UNIT
SIZE
SERIES
UNIT DIMENSIONS
MINIMUM MOUNTING
PAD DIMENSIONS
ABCD
E
F
G
H
K
L
M
Support Feet
Snow Stand
018
B
33-13/16
30
33
5-1/16
9-11/16
21-15/16
28-3/8
5/8
16-13/16
20-1/2
14
26 x 32
31 x 35
024
B
33-13/16
30
33
5-1/16
9-11/16
21-15/16
28-3/8
3/4
16-13/16
20-1/2
14
26 x 32
31 x 35
030
B
33-13/16
30
33
5-1/16
9-11/16
21-15/16
28-3/8
3/4
16-1/2
20-3/8
15
26 x 32
31 x 35
036
B
39-13/16
30
33
5-1/16
9-11/16
27-15/16
34-3/8
7/8
16-1/2
20-3/8
16
26 x 32
31 x 35
042
B
33-13/16
30
33
5-1/16
9-11/16
21-15/16
28-3/8
7/8
16-1/2
20-3/8
15
26 x 32
31 x 35
048
A
39-13/16
30
33
5-1/16
9-11/16
27-15/16
34-3/8
7/8
15-13/16
19-7/8
16
26 x 32
31 x 35
060
A
39-13/16
38-5/8
42-1/16
7-1/8
12-1/8
27-15/16
34-3/8
7/8
19-7/8
26
17-1/2
32 x 42
36 x 46