COMBINATION RATINGS* Continued
* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard: 80
°
F (27
°
C) db 67
°
F (19
°
C) wb indoor entering air temperature and 95
°
F (35
°
C) db air entering outdoor unit.
High-Temp Heating Standard: 70
°
F (21
°
C) db indoor entering air temperature and 47
°
F (8
°
C) db 43
°
F (6
°
C) wb air entering outdoor unit.
Low-Temp Heating Standard: 70
°
F (21
°
C) db indoor entering air temperature and 17
°
F (–9
°
C) db 15
°
F (–10
°
C) wb air entering outdoor unit.
† Outdoor section/indoor section combination tested in accordance with DOE test procedures for heat pumps. Ratings for other combinations are determined
under DOE computer simulation procedures.
‡ Requires hard shutoff TXV; based on computer simulation.
** TDR is on all furnaces, except 394HAD.
UNIT SIZE-
SERIES
AND
SOUND
RATING
(dBA)
INDOOR
UNIT
ARI STANDARD RATINGS*
Cooling
Heating
TC
Seasonal Efficiency SEER
High-Temp
Low-Temp
Seasonal
Efficiency
HSPF/HSPF
with LSV
Factory-
Supplied
Enhance-
ment
Standard
Rating
Field-Supplied
Accessory‡
TXV
TXV&TDR**
TC
COP
TC
COP
060-A
76
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA060
55,500
TDR
—
11.50
—
61,000
2.84
38,500
2.32
7.20/7.40
CD3(A,B)A060
55,500
TDR
—
11.50
—
61,000
2.84
38,500
2.32
7.20/7.40
CC5A/CD5A/CD5BW060
57,000
TDR
—
12.00
—
61,000
3.04
39,000
2.44
7.80/8.00
CE3AA060
57,500
TDR
—
12.00
—
61,000
3.02
39,000
2.42
7.80/8.00
CJ5A/CK5A/CK5BA060
57,500
TDR
—
12.00
—
61,000
2.94
38,500
2.40
7.50
CJ5A/CK5A/CK5BX060
58,500
TDR
—
12.20
—
61,000
3.12
38,500
2.48
7.80
CK3BA060
57,500
TDR
—
12.00
—
61,000
2.94
38,500
2.40
7.50
COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA060
55,000
TDR
—
11.50
—
61,000
2.80
39,000
2.30
7.20/7.40
CD3(A,B)A060
55,000
TDR
—
11.50
—
61,000
2.80
39,000
2.30
7.20/7.40
CC5A/CD5A/CD5BW060
56,500
TDR
—
12.00
—
61,000
3.02
39,000
2.42
7.50/7.70
CE3AA060
57,500
TDR
—
12.00
—
61,000
3.00
39,000
2.42
7.50/7.70
CJ5A/CK5A/CK5BA060
57,500
TDR
—
11.80
—
61,000
2.96
38,500
2.38
7.50
CJ5A/CK5A/CK5BX060
58,000
TDR
—
12.00
—
61,000
3.10
38,500
2.46
7.80
CK3BA060
57,500
TDR
—
11.80
—
61,000
2.96
38,500
2.38
7.50
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA060
55,000
TDR
—
11.20
—
61,000
2.80
39,500
2.30
7.20/7.40
CD3(A,B)A060
55,000
TDR
—
11.20
—
61,000
2.80
39,500
2.30
7.20/7.40
CC5A/CD5A/CD5BW060
56,500
TDR
—
11.50
—
61,000
3.00
39,500
2.40
7.50/7.70
SEER — Seasonal Energy Efficiency Ratio
LSV — Liquid Solenoid Valve
COP — Coefficient of Performance
TDR — Time-Delay Relay
HSPF — Heating Seasonal Performance Factor
TXV — Thermostatic Expansion Valve
TC — Total Capacity (Btuh)