background image

Fig.

12—Unit

Wiring

Diagram

A95335

PCB

BL

OWER

 O

FF 

DE

LAY

SE

LEC

T

IO

N CH

AR

T

90

SEC

135

SEC

180

SEC

225

SEC

GVR

H

I/L

O

RE

L

A

Y

SE

C-

1

SE

C-

2

PL

1

3

2

1

6

5

4

9

87

LE

D

TEST/TWIN

BL

OWER

OF

F

DE

LAY

G

R

Y

W

C

HU

M

HS

IR

ID

R

B

L

W

R

BL

OWER

SP

EED

SE

LEC

T

FU

1

C

OOL

HE

AT

L2

PL

3

PL

2

VA

C

120

L1

PR

1

1

2

1

2

3

PR

2

24 VA

C

-3A

FU

SE

SP

AR

E-

2

SP

AR

E-

1

EA

C-

1

EA

C-

2

C

1.5 A

MP

12

PL

5

WHT

BL

K

WHT

WHT

BLK

BLK

HS

I

BL

K

WHT

WHT   

(C

OM

)

RE

D  

 (

L

O)

BL

(M

ED

 LO

)

NO

TE

 #

8

OL

ST

ART

BL

W

M

YE

L (

M

ED

 H

I)

BL

 (

H

I)

BR

N

BR

N

TRAN

BL

U

RE

D

BL

K

WHT

WHT (

C

OM

)

GR

N

CA

P

RE

D

NO

TE

 #5

RE

D

OR

N

F

U

S

E

D

 DI

SC

ON

NE

C

T

SWI

T

CH

 (

W

HE

N REQ

’D

)

NO

TE

 #4

FU

2

BL

K

WHT

GR

N

GR

N

JB

LEGEND

AL

S

A

U

X

IL

IA

RY

 LI

M

IT 

SWI

T

CH

OV

ER

TEM

P

. -

M

ANU

A

RE

SET

SPS

T-

(N

.C

.)

BL

W

R

BL

OWER

 M

O

TOR

 R

E

LA

Y,

 SP

ST-

(N

.O

.)

BL

W

M

BL

OWER

 M

O

TOR

C

A

P

C

AP

AC

IT

O

R

CP

U

M

IC

RO

PRO

C

E

S

S

O

R

 AN

CI

RC

UI

TRY

D

S

S

D

RA

F

T

 SA

F

E

G

U

A

R

D SW

IT

CH

EA

C-

1

E

L

E

CT

RO

NI

C AIR

 C

L

EA

NE

R CO

NNE

CTI

O

N (115

 V

A

C 1.

A

M

P

 M

A

X

.)

EA

C-

2

E

L

E

CT

RO

NI

C AIR

 C

L

EA

NE

R CO

NNE

CTI

O

N (C

OM

MO

N)

FL

FU

SI

BLE LI

NK

FR

S

F

LA

ME

 R

O

LL

OU

T S

W

-M

AN

UA

L R

ESE

T,

 S

PST-

(N

.C

.)

F

S

E

F

LAM

E

 PR

OV

IN

G ELE

C

T

R

OD

E

FU

1

F

U

SE,

 3 

A

M

P

, AU

TOM

O

TIV

E

 BLAD

E TYP

E

FA

CTO

R

Y

 I

N

S

T

ALL

E

D

F

U

2

F

US

E

 OR

 C

IR

C

U

IT

 BR

E

A

K

E

R

 CU

RR

E

N

T

 I

N

T

E

RR

UP

T

 D

E

VI

CE

(F

IE

LD I

N

ST

ALLE

D & 

S

U

P

P

LI

ED)

G

V

G

AS VA

LVE-

R

E

DU

ND

ANT

 O

PER

ATO

R

S

G

V

R

G

AS VA

LVE RE

LAY

, DP

ST-

(N

.O

.)

HI

/L

O

B

L

O

WER

 M

O

TOR

 S

PEE

D CH

ANG

E

 RE

LAY

, SPD

T

HS

I

H

OT SU

RFA

C

E I

G

N

ITOR (

115 VAC

)

HS

IR

HO

T SU

RFA

C

E I

G

N

ITO

R RE

LAY

, SPS

T-

(N

.O

.)

HU

M

24V

AC 

HU

M

ID

IFI

ER

 C

O

N

N

EC

TI

ON

 (

.5

 A

M

P

MA

X.

)

ID

M

INDU

CE

D DRA

FT MO

TO

R

ID

R

INDU

CE

D DRA

FT RE

LAY

, SPS

T-

(N

.O

.)

IL

K

B

LO

W

E

R AC

CE

S

S

 PA

N

E

L

 IN

TE

R

L

O

C

K

 SW

IT

CH

, SP

ST

-(

N

.O.

)

JB

JU

N

C

TI

ON

 B

O

X

LE

D

L

IG

H

T

-E

M

ITT

IN

G DI

OD

E FOR

 S

T

AT

US CO

DE

S

LG

PS

LO

W G

AS 

PR

ES

SUR

E

 SWIT

CH

SPS

T-

(N

.O

.)

LS

LI

MI

T SWI

T

CH

, AU

TO RE

SET

, SPS

T(

N.

C.

)

O

L

AU

TO

-R

ESE

T IN

TER

N

AL M

O

TO

R O

VER

LOA

D

 TEM

P

. SW.

P

C

B

P

RI

NT

E

D

 CI

RC

UI

T

 B

O

A

R

D

P

L

1

9

-C

IR

CU

IT

 CO

NN

EC

T

O

R

P

L

2

2

-C

IR

CU

IT

 PC

B CO

NN

E

C

T

O

R

P

L

3

3

-C

IR

CU

IT

 ID

M C

O

N

N

E

C

T

O

R

PL5

2

-C

IR

C

U

IT

 H

S

I/

P

C

B CO

NN

EC

TOR

PR

S

P

R

ESS

UR

E S

W

IT

C

H

, S

PST

-(

N.

O

.)

TE

ST/

T

W

IN

C

O

M

PO

NEN

T

 TEST

 & TW

IN

 TER

M

IN

A

L

TR

AN

TR

ANS

F

O

R

M

E

R-115V

AC/

24VA

C

JU

NC

TI

ON

UN

M

A

RK

ED TE

RM

IN

AL

PC

B TER

M

IN

A

L

FA

CTO

R

Y

 WI

RI

NG

 (115VA

C

)

FA

CTO

R

Y

 W

IRI

NG

 (

24VA

C

)

FI

ELD

 WI

RI

NG

 (115VA

C

)

FI

ELD

 W

IRI

NG

 (

24VA

C

)

CO

ND

UC

TO

ON

 PC

B

FI

ELD

 W

IRI

NG

 TE

RM

IN

AL

F

IE

L

D GR

OU

ND

EQ

UI

PM

EN

T G

R

O

U

N

D

FI

ELD

 SP

LI

C

E

PLU

G

 RE

CEP

TAC

LE

L1

NE

UTR

A

L

L1

BLW

R

H

I/L

O

TO 11

5V

A

C

 FI

E

L

D DI

S

C

ONNE

CT

NOTE

 #4

EQ

UI

PM

EN

T G

R

O

U

N

D

SP

ARE

-2

HE

AT

SP

ARE

-1

C

OOL

NO

TE

 #8

CO

M

HS

IR

EA

C-

1

ST

ART

OL

CO

M

HI

M

E

D HI

ME

D

 L

O

LO

BLW

M

SCH

E

MATIC DIA

G

R

A

M

(NAT

URAL

 GAS &

 P

R

OPANE

)

EA

C-

2

1

1

HS

I

2

PL5

2

PL2

3

PL3

PR

2

115V

AC

PR

1

TR

AN

24VA

C

1

2

ID

R

T

E

S

T

/T

WIN

FU

1

NO

TE

 #6

CA

P

L2

PL1

GV

2-C

1-M

3-P

NO

TE

 #5

8

FS

E

9

6

5

CP

U

HS

IR

ID

R

BLW

R

Y

G

C

R

W

GV

R

-2

SE

C-

1

H

I/L

O

GV

R

GV

R

-1

SE

C-

2

NOT

ES:

32

2869

-101

 REV

. C

1.

If 

any 

of t

he 

or

ig

in

a

l equ

ip

m

e

n

t w

ire

 is

 r

epl

a

ced 

use 

wi

re

 r

a

ted

 for

 1

0

5

°C

.

2.

In

duce

r (I

DM

) an

d b

low

er

 (

B

L

W

M

) mo

tor

s co

nta

in i

n

te

rn

a

l aut

o-

re

set 

the

rm

a

l o

ver

lo

a

d

 sw

itche

s (

O

L)

.

3.

Bl

o

w

e

mo

tor

 sp

eed

 sel

e

cti

ons 

ar

e f

o

r ave

ra

g

e

 con

d

iti

o

n

s, se

e i

n

st

al

la

tion

 in

str

u

ct

io

ns f

o

r de

tai

ls

 o

n

op

tim

u

m

 spe

ed 

sel

e

cti

o

n.

4.

U

se o

n

ly

 co

ppe

r w

ir

e

 bet

we

en

 th

e d

isco

nn

ect sw

itch

 an

d th

e f

u

rn

a

ce j

u

n

cti

on

 bo

x (

JB)

.

5.

T

h

is

 w

ir

e

 m

u

st

 be

 con

nect

ed 

to f

u

rn

a

ce sh

eet

me

tal

 fo

r con

tr

o

l to

 de

tect 

flam

e.

6.

R

e

p

la

ce o

n

ly

 w

ith 

a 3

 am

fuse

.

7.

Ye

llo

w

 lead

 no

t o

n

 a

ll m

o

to

rs

.

8.

Bl

o

w

e

r-

o

n d

e

la

y, 

gas 

hea

ting

 45

 seco

nds,

 coo

lin

g o

hea

t p

u

m

p

 2

 seco

nd

s.

9.

Bl

o

w

e

r-

o

ff d

e

la

y, 

gas 

hea

ting

 90

, 13

5, 

180

 o

r 2

2

5

 seco

nds,

 coo

lin

g o

hea

t p

u

m

p

 9

0

 se

con

d

s.

(1

3

5

 se

cond

s on

ly

 on

 som

e

 mo

del

s)

1

0

.

Ig

n

itio

n

-lo

cko

u

t wi

ll o

ccu

r a

ft

e

r fo

u

r co

n

se

cu

tive

 u

n

su

cce

ssfu

l t

ria

ls-fo

r-ig

n

iti

o

n

C

o

n

tro

l w

ill a

u

to

-re

se

t

af

ter

 th

re

e h

o

u

rs.

1

1

.

W

h

e

n

 u

se

d

 a

u

xilia

ry lim

it switch

 (AL

S

) is o

n

 d

o

wn

flo

w

 mo

d

e

ls o

n

ly

. W

h

e

n

 u

se

d

 FL

 is o

n

 u

p

flo

w

mo

d

e

ls o

n

ly.

12

.

S

o

m

e

 m

o

d

e

ls

 m

a

y h

a

ve 

spad

qui

ck co

nn

ect t

e

rm

in

al

s.

BLK

OM

SW

2

SW

1

OM

2

3

4

7

1

OM

HU

M

ID

M

IL

K

DS

S

ALS

PR

S

IL

K

L1

NE

UTR

A

L

ID

M

(W

H

E

N US

E

D

)

NO

TE

 #11

NO

T US

ED

NO

T US

ED

NO

T US

ED

GR

N

2-

C

FS

E

1-

M

3-

P

GV

BL

U

YE

L

PR

S

DS

S

AL

S

(W

HE

N US

E

D

)

NOTE

 #12

WH

T

FR

S1

FR

S2

LS

FL

(W

H

E

N US

E

D

)

(N

OT

 ON

 A

L

L

 MO

DE

L

S

)

NO

TE

 #9

FR

S1

FR

S2

LS

FL

(W

H

E

N US

E

D

NO

TE

 #12

—10—

Содержание GB1AAV

Страница 1: ...en working on heating equipment observe precautions in the literature on tags and on labels attached to or shipped with the unit and other safety precautions that may apply Follow all safety codes In...

Страница 2: ...ouch ungrounded objects recharge your body with static electricity firmly touch furnace again before touching control or wires 5 Use this procedure for installed and uninstalled ungrounded furnaces 6...

Страница 3: ...th sides of the furnace d Slide filter s out e Replace filter if torn or disposable type If furnace is equipped with permanent washable filters Clean filters with tap water Spray water through filter...

Страница 4: ...6 Model GB1AAV Upflow A92063 C OM 24V HUM G R Y W DRAFT SAFEGUARD SWITCH FLUE COLLECTOR BOX MOUNTING SCREWS RELIEF BOX CONTROL BOARD FILTER RETAINER WASHABLE FILTER Fig 7 Model GB3AAV Downflow A92064...

Страница 5: ...on blower wheel blades The blower wheel should not be dropped or bent as balance will be affected 14 Reinstall blower wheel by reversing items 12 a through c Be sure wheel is positioned for proper rot...

Страница 6: ...h heat exchanger cell 1 Attach variable speed reversible drill to end of steel spring cable end opposite brush 2 Insert brush end of cable into upper opening of cell and slowly rotate with drill DO NO...

Страница 7: ...d for proper operation of the control board and flame sensing electrode The 24 v circuit contains an automotive type 3 amp fuse located on the control board See Fig 11 Any direct shorts of the 24 v wi...

Страница 8: ...on thermostat connection block See Fig 11 NOTE If TEST to Com terminals are jumpered longer than 2 sec LED will flash rapidly and retrieval request will be ignored e Component Test will function as de...

Страница 9: ...IGHT HARNESS CONNECTOR 24 V TRANSFORMER SEC 2 SPARE 1 SPARE 2 EAC 1 EAC ELECTRONIC AIR CLEANER TERMINALS 115 VAC 1 5 AMP MAX EAC 2 115 VAC L2 NEUTRAL CONNECTION 24 V THERMOSTAT TERMINALS BLOWER SPEED...

Страница 10: ...MPONENT TEST TWIN TERMINAL TRAN TRANSFORMER 115VAC 24VAC JUNCTION UNMARKED TERMINAL PCB TERMINAL FACTORY WIRING 115VAC FACTORY WIRING 24VAC FIELD WIRING 115VAC FIELD WIRING 24VAC CONDUCTOR ON PCB FIEL...

Страница 11: ...lay 33 LIMIT OR FLAME ROLL OUT SWITCH IS OPEN If open longer than three minutes code changes to 13 Check for Defective blower motor or start capacitor Dirty filter or restricted duct system Loose blow...

Страница 12: ...tatus code The status code is a 2 digit number with the first digit determined by the number of short flashes and the second digit by the number of long flashes Once status code is determined the cont...

Страница 13: ...ault is cleared Check for Stuck open gas valve solenoid or leak Defective control board 23 PRESSURE SWITCH WILL NOT OPEN Check for Disconnected or obstructed pressure tubing Defective pressure switch...

Страница 14: ...t theory and skills programs is available using popular video based formats and materials All include video and or slides plus companion book Classroom Service Training plus hands on the products in o...

Страница 15: ...15...

Страница 16: ...1996 CAC BDP P O Box 70 Indianapolis IN 46206 sggb1a09 16 Book Tab 1 6a 4 8a Catalog No 92 33GB 1A23...