NOTE:

Read the entire instruction manual before performing any service or maintenance.

Index

Page

SAFETY CONSIDERATIONS .................................................................................................................................................................................1-2
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS

PROCEDURE...........................................................................................................................................................................................................2

CARE AND MAINTENANCE .................................................................................................................................................................................2-8

Air Filter Arrangement .........................................................................................................................................................................................2-3
Blower Motor and Wheel .....................................................................................................................................................................................3-5
Cleaning Heat Exchanger .....................................................................................................................................................................................5-7
Electrical Controls and Wiring .............................................................................................................................................................................7-8
Troubleshooting...................................................................................................................................................................................................8-13
Unit Wiring Diagram .............................................................................................................................................................................................10
Service Label ..........................................................................................................................................................................................................11
Troubleshooting Guide......................................................................................................................................................................................12-13

SAFETY CONSIDERATIONS

Installing and servicing heating equipment can be hazardous due to gas and electrical components. Only trained and qualified personnel should
install, repair, or service heating equipment.

Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed
by trained service personnel. When working on heating equipment, observe precautions in the literature, on tags, and on labels attached to or
shipped with the unit and other safety precautions that may apply.

Follow all safety codes. In the United States, follow all safety codes including the National Fuel Gas Code (NFGC) NFPA No. 54-1992/ANSI
Z223.1-1992. In Canada, refer to the current edition of the National Standard of Canada CAN/CGA-B149.1- and .2-M95 Natural Gas and Propane
Installation Codes (NSCNGPIC). Wear safety glasses and work gloves. Have fire extinguisher available during start-up and adjustment procedures
and service calls.

Fig. 3—Model GB1AAV

Upflow

A94085

Fig. 2—Model GB3AAV

Downflow

A94086

Fig. 1—Model GB3AAV Horizontal

A94087

®

ama

CANADIAN   GAS   ASSOCIATION

A PP R O VED

R

CERTIFICATION OF
MANUFACTURING SITE

Service and Maintenance Instructions

GB1AAV
GB3AAV

HSI Mid-Efficiency
Induced-Combustion Furnaces
Sizes 045 thru 155
Series G

Form:

SG-GB1A-09

Cancels:

SG-GB1A-08

Printed in U.S.A.

5-96

Catalog No.

92-33GB-1A23

Содержание GB1AAV

Страница 1: ...en working on heating equipment observe precautions in the literature on tags and on labels attached to or shipped with the unit and other safety precautions that may apply Follow all safety codes In...

Страница 2: ...ouch ungrounded objects recharge your body with static electricity firmly touch furnace again before touching control or wires 5 Use this procedure for installed and uninstalled ungrounded furnaces 6...

Страница 3: ...th sides of the furnace d Slide filter s out e Replace filter if torn or disposable type If furnace is equipped with permanent washable filters Clean filters with tap water Spray water through filter...

Страница 4: ...6 Model GB1AAV Upflow A92063 C OM 24V HUM G R Y W DRAFT SAFEGUARD SWITCH FLUE COLLECTOR BOX MOUNTING SCREWS RELIEF BOX CONTROL BOARD FILTER RETAINER WASHABLE FILTER Fig 7 Model GB3AAV Downflow A92064...

Страница 5: ...on blower wheel blades The blower wheel should not be dropped or bent as balance will be affected 14 Reinstall blower wheel by reversing items 12 a through c Be sure wheel is positioned for proper rot...

Страница 6: ...h heat exchanger cell 1 Attach variable speed reversible drill to end of steel spring cable end opposite brush 2 Insert brush end of cable into upper opening of cell and slowly rotate with drill DO NO...

Страница 7: ...d for proper operation of the control board and flame sensing electrode The 24 v circuit contains an automotive type 3 amp fuse located on the control board See Fig 11 Any direct shorts of the 24 v wi...

Страница 8: ...on thermostat connection block See Fig 11 NOTE If TEST to Com terminals are jumpered longer than 2 sec LED will flash rapidly and retrieval request will be ignored e Component Test will function as de...

Страница 9: ...IGHT HARNESS CONNECTOR 24 V TRANSFORMER SEC 2 SPARE 1 SPARE 2 EAC 1 EAC ELECTRONIC AIR CLEANER TERMINALS 115 VAC 1 5 AMP MAX EAC 2 115 VAC L2 NEUTRAL CONNECTION 24 V THERMOSTAT TERMINALS BLOWER SPEED...

Страница 10: ...MPONENT TEST TWIN TERMINAL TRAN TRANSFORMER 115VAC 24VAC JUNCTION UNMARKED TERMINAL PCB TERMINAL FACTORY WIRING 115VAC FACTORY WIRING 24VAC FIELD WIRING 115VAC FIELD WIRING 24VAC CONDUCTOR ON PCB FIEL...

Страница 11: ...lay 33 LIMIT OR FLAME ROLL OUT SWITCH IS OPEN If open longer than three minutes code changes to 13 Check for Defective blower motor or start capacitor Dirty filter or restricted duct system Loose blow...

Страница 12: ...tatus code The status code is a 2 digit number with the first digit determined by the number of short flashes and the second digit by the number of long flashes Once status code is determined the cont...

Страница 13: ...ault is cleared Check for Stuck open gas valve solenoid or leak Defective control board 23 PRESSURE SWITCH WILL NOT OPEN Check for Disconnected or obstructed pressure tubing Defective pressure switch...

Страница 14: ...t theory and skills programs is available using popular video based formats and materials All include video and or slides plus companion book Classroom Service Training plus hands on the products in o...

Страница 15: ...15...

Страница 16: ...1996 CAC BDP P O Box 70 Indianapolis IN 46206 sggb1a09 16 Book Tab 1 6a 4 8a Catalog No 92 33GB 1A23...

Отзывы: