Page 108
SECTION 4.4
DIAGNOSTIC TESTS
PART 4
DC CONTROL
3. Crank the engine until there is no further increase in
pressure.
4. Record the highest reading obtained.
5. Repeat the procedure for the remaining cylinder and
record the highest reading.
RESULTS:
The difference in pressure between the two cylinders
should not exceed 25 percent. If the difference is
greater than 25 percent, loss of compression in the
lowest reading cylinder is indicated.
Example 1: If the pressure reading of cylinder #1
is 65 psi and of cylinder #2, 60 psi, the difference
is 5 psi. Divide "5" by the highest reading (65) to
obtain the percentage of 7.6 percent.
Example 2:
No. 1 cylinder reads 75 psi; No. 2
cylinder reads 55 psi. The difference is 20 psi. Divide
"20" by "75" to obtain "26.7" percent. Loss of
compression in No. 2 cylinder is indicated.
If compression is poor, look for one or more of the
following:
• Loose cylinder head bolts.
• Failed cylinder head gasket.
• Burned valves or valve seats.
• Insufficient valve clearance.
• Warped cylinder head.
• Warped valve stem.
• Worn or broken piston ring(s).
• Worn or damaged cylinder bore.
• Broken connecting rod.
• Worn valve seats or valves.
TEST 58 - CHECK SHUTDOWN WIRE
DISCUSSION:
Circuit board action during shutdown will ground Wire
18. Wire 18 is connected to the Ignition Magneto(s).
The grounded magneto will not be able to produce
spark.
PROCEDURE:
1. On v-twin generators, remove Wire 18 from the stud
located above the oil cooler. On single cylinder
generators, disconnect Wire 18 at the bullet connector.
2. Perform Test 55.
3. If spark now occurs with Wire 18 removed, check for a
short to ground. Set the Auto-Off-Manual switch to OFF.
Remove the 17 pin connector J1 from the circuit board.
4. Set a VOM to measure resistance. Connect one test
lead to Wire 18 from the control panel. Connect the
other test lead to a clean frame ground. INFINITY
should be measured.
5. Reconnect the J1 connector to the circuit board.
6. Set a VOM to measure resistance. Connect one test
lead to Wire 18 from the control panel. Connect the
other test lead to a clean frame ground. Set the Auto-
Off-Manual switch to MANUAL. During cranking the
meter should read infinity.
RESULTS:
1. If INFINITY was not measured in Step 4, repair or
replace shor ted ground Wire 18 between the J1
connector from the circuit board to the stud or bullet
connector.
2. If INFINITY was not measured in Step 6 during cranking,
replace the circuit board and retest for spark.
3. If ignition spark still has not occurred, proceed to
Test 59.
TEST 59 - CHECK AND ADJUST IGNITION
MAGNETOS
DISCUSSION:
In Test 55, a spark tester was used to check for
engine ignition. If sparking or weak spark occurred,
one possible cause might be the ignition magneto(s).
This test consists of adjusting the air gap between the
ignition magneto(s) and the flywheel. The flywheel
and flywheel key will also be checked during this test.
PROCEDURE:
Note: The air gap between the ignition magneto
and the flywheel on single cylinder engines is
non-adjustable. Proceed directly to Steps 15,16
and 17 for single cylinder engines. For V-twin
engines, proceed as follows.
1. See Figure 23. Rotate the flywheel until the magnet is
under the module (armature) laminations.
2. Place a 0.008-0.012 inch (0.20-0.30mm) thickness
gauge between the flywheel magnet and the module
laminations.
3. Loosen the mounting screws and let the magnet pull the
magneto down against the thickness gauge.
4. Tighten both mounting screws.
5. To remove the thickness gauge, rotate the flywheel.
6. Repeat the above procedure for the second magneto.
Содержание ASPAS1BBA007
Страница 4: ...Page 4 SPECIFICATIONS MOUNTING DIMENSIONS...
Страница 5: ...Page 5 SPECIFICATIONS MOUNTING DIMENSIONS...
Страница 24: ...Page 24 NOTES PART 1 GENERAL INFORMATION...
Страница 32: ...Page 32 SECTION 2 3 TROUBLESHOOTING FLOWCHARTS PART 2 AC GENERATORS...
Страница 33: ...Page 33 SECTION 2 3 TROUBLESHOOTING FLOWCHARTS AC GENERATORS PART 2...
Страница 34: ...Page 34 SECTION 2 3 TROUBLESHOOTING FLOWCHARTS PART 2 AC GENERATORS...
Страница 60: ...Page 60 SECTION 3 3 TROUBLESHOOTING FLOW CHARTS PART 3 V TYPE PREPACKAGED TRANSFER SWITCHES...
Страница 70: ...Page 70 SECTION 3 4 DIAGNOSTIC TESTS PART 3 V TYPE PREPACKAGED TRANSFER SWITCHES...
Страница 90: ...Page 90 SECTION 4 3 TROUBLESHOOTING FLOW CHARTS PART 4 DC CONTROL...
Страница 91: ...Page 91 SECTION 4 3 TROUBLESHOOTING FLOW CHARTS DC CONTROL PART 4...
Страница 92: ...Page 92 SECTION 4 3 TROUBLESHOOTING FLOW CHARTS PART 4 DC CONTROL...
Страница 93: ...Page 93 SECTION 4 3 TROUBLESHOOTING FLOW CHARTS DC CONTROL PART 4...
Страница 94: ...Page 94 SECTION 4 3 TROUBLESHOOTING FLOW CHARTS PART 4 DC CONTROL...
Страница 95: ...Page 95 SECTION 4 3 TROUBLESHOOTING FLOW CHARTS DC CONTROL PART 4...
Страница 138: ...PART 7 ELECTRICAL DATA WIRING DIAGRAM 8 CIRCUIT LOAD CENTER Page 138 DRAWING 0E7687A...
Страница 140: ...Page 140 DRAWING 07687 PART 7 ELECTRICAL DATA WIRING DIAGRAM 10 12 CIRCUIT LOAD CENTER...
Страница 142: ...Page 142 PART 7 ELECTRICAL DATA NOTES...
Страница 144: ...Part No 0F4676 Revision 02 25 05 Printed in U S A Catalog No DMASPAS 07 1...