INTRODUCTION

Thank you for purchasing this model of the Bryant

product line. This model is a compact, high performance,

air-cooled, engine-driven generator designed to

automatically supply electrical power to operate critical

loads during a utility power failure.
This unit is factory installed in an all-weather, metal enclosure

that is intended exclusively for outdoor installation. This

generator will operate using either vapor withdrawn liquid

propane (LP) or natural gas (NG).

READ THIS MANUAL THOROUGHLY

If any portion of this manual is not understood, contact the

nearest Bryant Dealer for starting, operating and servicing

procedures.
Throughout this publication, and on tags and 

decals affixed to the generator, DANGER, WARNING,

CAUTION and NOTE blocks are used to alert personnel

to special instructions about a particular operation that

may be hazardous if performed incorrectly or carelessly.

Observe them carefully. Their definitions are as follows:

After this heading, read instructions that, if not
strictly complied with, will result in serious
personal injury, including death, in addition to
property damage.

After this heading, read instructions that, if not
strictly complied with, may result in serious
personal injury or property damage.

After this heading, read instructions that, if not
strictly complied with, could result in damage to
equipment and/or property.

NOTE:

After this heading, read explanatory statements

that require special emphasis.

These safety warnings cannot eliminate the hazards

that they indicate. Common sense and strict

compliance with the special instructions while

performing the service are essential to preventing

accidents.

Four commonly used safety symbols accompany the

DANGER, WARNING and CAUTION blocks. The type of

information each indicates follows:

This symbol points out important safety
information that, if not followed, could
endanger personal safety and/or property of
others.

This symbol points out potential explosion
hazard.

This symbol points out potential fire hazard.

This symbol points out potential electrical
shock hazard.

The operator is responsible for proper and safe use 

of the equipment. Bryant strongly recommends that the

operator read this 

Owner's Manual

and thoroughly

understand all instructions before using this equipment.

Bryant also strongly recommends instructing other users

to properly start and operate the unit. This prepares them

if they need to operate the equipment in an emergency.

CONTENTS

This manual contains pertinent owner’s information,

including warranty, electrical diagrams, exploded views

and lists of repair parts, for three different Bryant models:

ASPAS1BBA007

– 6 kW NG, 7 kW LP, single-cylinder

GH-410 Engine

ASPAS1BBA012

– 12 kW NG, 12 kW LP, V-twin GT-

990 Engine

ASPAS1BBA015

– 13 kW NG, 15 kW LP, V-twin GT-

990 Engine

OPERATION AND MAINTENANCE

It is the operator's responsibility to perform all safety

checks, to make sure that all maintenance for safe

operation is performed promptly, and to have the

equipment checked periodically by a Bryant Dealer.

Normal maintenance service and replacement of parts

are the responsibility of the owner/operator and, as such,

are not considered defects in materials or workmanship

within the terms of the warranty. Individual operating

habits and usage contribute to the need for maintenance

service.
Proper maintenance and care of the generator ensures a

minimum number of problems and keep operating

expenses at a minimum. See a Bryant Dealer for service

aids and accessories.

HOW TO OBTAIN SERVICE

When the generator requires servicing or repairs, contact

a Bryant Dealer for assistance. Service technicians are

factory-trained and are capable of handling all service

needs.
When contacting a Bryant Dealer about parts and service,

always supply the complete model number and serial

number of the unit as given on its data decal, which is

located on the generator. See Figure 1.1 or Figure 1.2 in

Section 1.4 for decal location.

Model No. ____________ Serial No. ____________

‹

‹

‹

!

DANGER

‹

Содержание ASPAS1BBA

Страница 1: ...ic Standby Generators Models ASPAS1BBA007 6 kW NG 7 kW LP ASPAS1BBA012 12 kW NG 12 kW LP ASPAS1BBA015 13 kW NG 15 kW LP DEADLY EXHAUST FUMES OUTDOOR INSTALLATION ONLY DANGER Not intended for use as Pr...

Страница 2: ...d or property of others This symbol points out potential explosion hazard This symbol points out potential fire hazard This symbol points out potential electrical shock hazard The operator is responsi...

Страница 3: ...ery Installation 8 1 11 The Battery 8 Section 2 Operation 9 2 1 Break in Procedure 9 2 2 Using the Auto Off Manual Switch 9 2 3 Automatic Transfer Operation 10 2 4 Sequence of Automatic Operation 10 2...

Страница 4: ...mpliance with applicable codes and standards Following installation do nothing that might render the system unsafe or in noncompliance with such codes and standards Keep hands feet clothing etc away f...

Страница 5: ...ed in accordance with the manufacturer s instructions and recommendations Following proper installation do nothing that might alter a safe installation and render the unit in noncompliance with the af...

Страница 6: ...the control panel to notify personnel that one of these faults has occurred There is also a System Set LED that is lit when all of the conditions describe in Section 1 3 are true 1 3 NEC REQUIREMENT F...

Страница 7: ...ck Data Decal Control Panel Fuel Regulator Fuel Inlet GFCI Outlet Oil Filter Battery Compartment Exhaust Enclosure Oil Filter Battery Compartment Fuel Inlet GFCI Outlet Control Panel Data Decal Oil Di...

Страница 8: ...as fuel Btu content ambient temperature altitude engine power and condition etc Maximum power decreases about 3 5 percent for each 1 000 feet above sea level and also will decrease about 1 percent for...

Страница 9: ...liquid propane LP gas are highly explosive Even the slightest spark can ignite such fuels and cause an explosion No leakage of fuel is permitted Natural gas which is lighter than air tends to collect...

Страница 10: ...hock and high short circuit current The following precautions are to be observed when working on batteries Remove the 7 5A and 15A fuses from the generator control panel Remove watches rings or other...

Страница 11: ...unit will continue to run for one minute and then shut down 9 Allow the unit to cool 10 Set the generator s main circuit breaker to its OFF or OPEN position 11 Set the generator s AUTO OFF MANUAL swi...

Страница 12: ...tor is not running This outlet is protected by a 15 amp circuit breaker located in the generator control panel Figure 3 1 2 4 SEQUENCE OF AUTOMATIC OPERATION The generator s control panel houses a con...

Страница 13: ...e should shut down 4 Check that utility power supply to the transfer switch is turned OFF Do not attempt to activate the transfer switch manually until all power voltage supplies to the switch have be...

Страница 14: ...light indicating an over crank failure The AUTO OFF MANUAL switch will need to be set to OFF and then back to AUTO to reset the generator control board NOTE If the fault is not repaired the over cran...

Страница 15: ...kW Figure 3 3 Oil Dipstick and Fill 12 kW and 15 kW 3 3 CHANGING THE ENGINE OIL 3 3 1 ENGINE OIL RECOMMENDATIONS Use oil of American Petroleum Institute API Service Class SG SH or SJ Use all season S...

Страница 16: ...side of the air box and around edges 4 Install the new air cleaner into the air box 5 Install the cover Turn the two cover screws clockwise to tighten See the Service Schedule Section 4 1 for air clea...

Страница 17: ...trolyte contacts the eyes flush thoroughly and immediately with water and seek medical attention and Spilled electrolyte is to be washed down with an acid neutralizing agent A common practice is to us...

Страница 18: ...completely Refill the crankcase with oil See Engine Oil Recommendations Section 3 3 1 7 Attach a tag to the engine indicating the viscosity and classification of the oil in the crankcase 8 Remove the...

Страница 19: ...Repair is Needed FUEL Fuel lines and connections X M LUBRICATION Oil level X M Oil X AFTER BREAK IN AND Y Oil filter X AFTER BREAK IN AND Y COOLING Enclosure louvers X X W BATTERY Remove corrosion X X...

Страница 20: ...and runs rough or damaged 2 Defective spark plug s 2 Clean re gap or replace plug s 3 Fuel Regulator not set 3 Set Fuel Regulator 4 Fuel Pressure incorrect 4 Confirm fuel pressure to regulator is 11...

Страница 21: ...misuse abuse negligence or improper installation As with all mechanical devices the Bryant engines need periodic part s service and replacement to perform well Failures caused by any external cause or...

Страница 22: ...ngine or a part component thereof has failed due to abuse neglect improper maintenance or unapproved modifications or the use of counterfeit and or grey market parts not made supplied or approved by G...

Страница 23: ...elow Any such emissions related part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point for such...

Страница 24: ...PART NO 0F4108 13AS PA1 REV A 12 17 04 FORM OM18 1 PRINTED IN U S A...

Отзывы: