background image

10

NOTE TO EQUIPMENT OWNER:

For your convenience, please record the model and serial numbers of your new equipment in the spaces

provided. This information, along with the installation data and dealer contact information will be helpful

should your system require maintenance or service.

FURNACE

Model # _____________________________________
Serial # ______________________________________

AIR CONDITIONER OR HEAT PUMP

Model # _____________________________________
Serial # _____________________________________

INDOOR COIL (Furnace Coil or Fan Coil)

Model # _____________________________________
Serial # _____________________________________

INSTALLATION INFORMATION:

Date Installed ________________________________

DEALERSHIP CONTACT INFORMATION:

Company Name_______________________________
Address______________________________________
_____________________________________________
Phone Number _______________________________
Technician Name _____________________________
_____________________________________________
_____________________________________________

NOTE TO INSTALLER:

This manual must be left with the equipment owner.

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Copyright 2008 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indianapolis, IN 46231

Heating & Cooling Systems

TO OBTAIN INFORMATION ON PARTS: Consult your installing dealer or classified section of your local telephone directory under the

“Heating Equipment” or “Air Conditioning Contractors & Systems” heading for dealer listing by brand name.

Have available the Model No., Series Letter, & Serial No. of your equipment to ensure correct replacement part.

Printed in the U.S.A.

Replaces: OM05--- 52

Catalog No: OM05---55

Edition Date: 11/08

Содержание A02182

Страница 1: ... service agency or the gas supplier WARNING CARBON MONOXIDE POISONING HAZARD Failure to follow this warning could result in personal injury and or death Carbon Monoxide is invisible odorless and toxic Bryant Heating and Cooling Systems recommends a carbon monoxide alarm in your home even if you do not own a gas appliance Locate the carbon monoxide alarm in the living area of your home and away fro...

Страница 2: ...tilation Warning 6 4 Starting Lighting and Shutting Down the Furnace Warning 4 5 5 Draft Safeguard Switch Caution 8 6 Proper Furnace Shutdown Procedures 5 7 Flood Damage Warning 1 8 Fire or Explosion Hazard Warning 1 9 Carbon Monoxide Warning 1 10 Service and Maintenance Electrical Hazard Warning 6 11 Improper Vent Warning 6 12 Sharp Edges Caution 6 13 No Filter Caution 6 14 Filter Rod Modificatio...

Страница 3: ...to follow this safety warning could result in injury death or property damage Do not keep combustible materials gasoline and other flammable liquids or vapors around your furnace WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings could result in personal injury death or property damage Keep insulation clear of furnace and maintain clearances shown on unit clearance label WARNING BE...

Страница 4: ...l to shut off or if overheating occurs turn off the manual gas valve to the furnace BEFORE turning off the electrical supply and install lockout tag WARNING S CHECK AIR FILTER Before attempting to start your furnace be sure the furnace filter is clean and in place See Performing Routine Maintenance section in this manual Do not run the furnace without a filter in place Then proceed as follows STEP...

Страница 5: ...ed on the thermostat the furnace will switch on automatically When the room temperature reaches the setting selected on the thermostat the furnace will be automatically switched off Continuous Fan Operation Some thermostats have a FAN switch with 2 selections AUTO and ON When thermostat is set on AUTO the furnace blower cycles on and off controlled by the thermostat In ON position the furnace blow...

Страница 6: ...e can cause a loss of efficiency CAUTION A dirty filter will cause excessive stress on the furnace heat exchanger and blower motor and can cause it to overheat and automatically shut down The furnace filter should be checked every 4 weeks and cleaned or replaced if necessary If installed with factory specified disposable media filter check or replace filter before each heating and cooling season R...

Страница 7: ... If side return ducts are used 2 filters may be required in some models The procedure listed above may be used to remove side filters PERSONAL INJURY HAZARD Failure to follow this caution may result in personal injury Use care when cutting support rods in filters to protect against flying pieces and sharp rod ends Wear safety glasses gloves and appropriate protective clothing CAUTION Filters may b...

Страница 8: ...e makes a loud noise when the main burners are ignited shut down the furnace and call your servicing dealer Use your flashlight and follow these steps for inspecting the combustion area and vent system of your furnace 1 Turn off electrical supply to the furnace and remove the access door See Fig 6 and 7 2 Carefully inspect the gas burner for dirt rust or scale Inspect the elbow flue connection are...

Страница 9: ...adequate combustion air these switches will shut off the furnace Reset the switches by pushing the button on the switch If the switch trips a second time turn off the furnace and call for service S If your furnace still fails to operate call your servicing dealer for troubleshooting and repairs Tell your dealer the model and serial numbers for your furnace You should have them recorded on page 10 ...

Страница 10: ...dress______________________________________ _____________________________________________ Phone Number _______________________________ Technician Name _____________________________ _____________________________________________ _____________________________________________ NOTE TO INSTALLER This manual must be left with the equipment owner Manufacturer reserves the right to change at any time speci...