background image

6

PERFORMING ROUTINE MAINTENANCE

With proper maintenance and care, your furnace will operate

economically and dependably. Instructions for basic maintenance
are found on this and the following pages. However, before

beginning maintenance, follow these safety precautions:

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal

injury or death.
Turn off electrical power supply to your furnace before

removing the access doors to service or perform

maintenance.

!

WARNING

CUT HAZARD

Failure to follow this caution may result in personal injury.
Although special care has been taken to minimize sharp

edges, be extremely careful when handling parts or reaching

into the furnace.

Wear safety glasses, gloves, and

appropriate protective clothing.

CAUTION

!

FILTERING OUT TROUBLE

UNIT PERFORMANCE HAZARD

Failure to follow this caution may result in product damage.
Never operate your furnace without a filter in place. Doing

so may damage the furnace blower motor.

An

accumulation of dust and lint on internal parts of your

furnace can cause a loss of efficiency.

CAUTION

!

A dirty filter will cause excessive stress on the furnace, heat

exchanger, and blower motor and can cause it to overheat and
automatically shut down. The furnace filter should be checked

every 4 weeks and cleaned or replaced if necessary.
If installed with factory specified disposable media filter, check or

replace filter before each heating and cooling season. Replace
disposable media filter at least twice a year.
If your furnace filter needs replacing, be sure to use the same size

and type of filter that was originally specified. The air filter for the
furnace may be located in a filter cabinet attached to the side or

bottom of the furnace. If air filter has been installed in another
location, contact your dealer for instructions. To inspect, clean

and/or replace the air filter(s), follow these steps:

1. Turn off the electrical supply to the furnace.

A92185

Fig. 13 -- Turn Off Electrical Supply

2. Remove filter cabinet door (See Fig. 14 and 15.)

NOTE

: It may be necessary to remove 1 thumbscrew.

A06190

Fig. 14 -- Removing Side Filter Cabinet Door

A06191

Fig. 15 -- Removing Bottom Filter Cabinet Door

3. Slide air filter out of filter cabinet. Keep dirty side up (if

dirty) to avoid spilling dirt. (See Fig. 16 and 17.)

Содержание A02182

Страница 1: ... service agency or the gas supplier WARNING CARBON MONOXIDE POISONING HAZARD Failure to follow this warning could result in personal injury and or death Carbon Monoxide is invisible odorless and toxic Bryant Heating and Cooling Systems recommends a carbon monoxide alarm in your home even if you do not own a gas appliance Locate the carbon monoxide alarm in the living area of your home and away fro...

Страница 2: ...tilation Warning 6 4 Starting Lighting and Shutting Down the Furnace Warning 4 5 5 Draft Safeguard Switch Caution 8 6 Proper Furnace Shutdown Procedures 5 7 Flood Damage Warning 1 8 Fire or Explosion Hazard Warning 1 9 Carbon Monoxide Warning 1 10 Service and Maintenance Electrical Hazard Warning 6 11 Improper Vent Warning 6 12 Sharp Edges Caution 6 13 No Filter Caution 6 14 Filter Rod Modificatio...

Страница 3: ...to follow this safety warning could result in injury death or property damage Do not keep combustible materials gasoline and other flammable liquids or vapors around your furnace WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings could result in personal injury death or property damage Keep insulation clear of furnace and maintain clearances shown on unit clearance label WARNING BE...

Страница 4: ...l to shut off or if overheating occurs turn off the manual gas valve to the furnace BEFORE turning off the electrical supply and install lockout tag WARNING S CHECK AIR FILTER Before attempting to start your furnace be sure the furnace filter is clean and in place See Performing Routine Maintenance section in this manual Do not run the furnace without a filter in place Then proceed as follows STEP...

Страница 5: ...ed on the thermostat the furnace will switch on automatically When the room temperature reaches the setting selected on the thermostat the furnace will be automatically switched off Continuous Fan Operation Some thermostats have a FAN switch with 2 selections AUTO and ON When thermostat is set on AUTO the furnace blower cycles on and off controlled by the thermostat In ON position the furnace blow...

Страница 6: ...e can cause a loss of efficiency CAUTION A dirty filter will cause excessive stress on the furnace heat exchanger and blower motor and can cause it to overheat and automatically shut down The furnace filter should be checked every 4 weeks and cleaned or replaced if necessary If installed with factory specified disposable media filter check or replace filter before each heating and cooling season R...

Страница 7: ... If side return ducts are used 2 filters may be required in some models The procedure listed above may be used to remove side filters PERSONAL INJURY HAZARD Failure to follow this caution may result in personal injury Use care when cutting support rods in filters to protect against flying pieces and sharp rod ends Wear safety glasses gloves and appropriate protective clothing CAUTION Filters may b...

Страница 8: ...e makes a loud noise when the main burners are ignited shut down the furnace and call your servicing dealer Use your flashlight and follow these steps for inspecting the combustion area and vent system of your furnace 1 Turn off electrical supply to the furnace and remove the access door See Fig 6 and 7 2 Carefully inspect the gas burner for dirt rust or scale Inspect the elbow flue connection are...

Страница 9: ...adequate combustion air these switches will shut off the furnace Reset the switches by pushing the button on the switch If the switch trips a second time turn off the furnace and call for service S If your furnace still fails to operate call your servicing dealer for troubleshooting and repairs Tell your dealer the model and serial numbers for your furnace You should have them recorded on page 10 ...

Страница 10: ...dress______________________________________ _____________________________________________ Phone Number _______________________________ Technician Name _____________________________ _____________________________________________ _____________________________________________ NOTE TO INSTALLER This manual must be left with the equipment owner Manufacturer reserves the right to change at any time speci...