43
Technical data
and start-up
PDU254
PROCEDURE STEP
ILLUSTRATION / OTHER INFORMATION
6.
Insulate 16 mm of the HV cable (1).
7.
Assemble the cable lug (1) at the end of the cable.
No strands should stick out at the sides!
The crimping must be hexagonal. Ensure that
the crimping has no deformations at the sides
because this will make later installations in the
housing difficult!
8.
Check the secure positioning of the cable lug
manually.
---
9.
Assemble a shrinkage tube (1) on the cable lug (2).
The assembly of a shrinkage tube (1) is
absolutely necessary because otherwise
contacting can result in the housing!
INSTRUCTION
During the layout of the cable take care that
the first part of the cable is at least 5cm
straight before it will be bend to a radius.
INSTRUCTION
If you have to reassembly the cable you have to use a new terminal insert. Otherwise it can cause a
leakage.
The terminal inserts can be ordered from BRUSA Elektronik AG or directly from
hummel.com
.
5cm