Page 9
PANEL LAYOUT
A generalized panel layout sheet is located on the last page of this document. Print a copy and fill in the information for
each breaker. This will greatly simplify setting up the GEM CTs and DashBox channels later. Each field is defined below.
The picture (below) shows part of the channel info sheet on the left and a section of breakers represented.
F
IELDS
Panel #
“Panel #” is the breaker slot number on the panel itself
Load Description
“Load Description” is the name of the appliance, outlet, light, etc. connected to this breaker
CT #
“CT #” is the number on the CT leads. This allows the installer to know which CT leads represent each
channel when it comes time to connecting the leads to the GEM.
Not all CTs have numbered labels attached. If this is the case, it is advisable to put a small piece of
masking tape at the end of the CT leads after the CT has been installed and the leads have been routed
outside of the panel
CT Model
“CT Model” is the Brultech model number of the CT
Amps
“Amps” is the amperage rating of the circuit breaker
240V-120V-240V
Circle the voltage that represents the breaker. If it’s a 240V breaker it is typically coupled with a breaker
adjacent to it. In this case, circle the two together as shown in the picture above.
Содержание DashBox
Страница 35: ...Appendix B Page 34...