VIBROCONTROL 920
Setups
__________________________________________________________________________________
Page 16 / 33
VC920E / C102833.002 / V 13
Mode 4 Limit value LIM 2
Default value: 7 mm/s
The adjustable range of the limit value is from 0 to the full scale value of the
selected range. The resolution of the steps in the adjustment is in every case
dependent on the selected range.
Range
Resolution
0 ... 10 mm/s
0,1 mm/s
0 ... 20 mm/s
0,1 mm/s
0 ... 50 mm/s
0,2 mm/s (x,0 - x,2 - x,5 - x,7)
0 ... 100 mm/s
1 mm/s
Mode 5 Time delay LIM 1
Default value: 10 s
The range of the adjustable time delay is from 0 ... 100 s. in steps of
1 second. The parameter is only effective when there is a limit exceedance.
Note:
The minimum setting „0" corresponds to a time delay of 1 second.
Mode 6 Time delay LIM 2
Default value: 5 s
The range of the adjustable time delay is from 0 ... 100 s. in steps of
1 second. The parameter is only effective when there is a limit exceedance.
Note:
The minimum setting „0" corresponds to a time delay of 1 second.
Mode 7 High-pass filter value
Default value: 10 Hz
Entered value
Active filter value
1
1 Hz (Vers. > 2.8)
10
10 Hz