8.2
Digital Output
NOTE!
The Digital Output functionality is supported from VCM-3 Firmware version 1.15 or
higher.
Digital Output
– connections
The digital output on VCM-3 is implemented using photo relays. The photo relays used for the digital outputs
are rated for an on-current of 1A up to 50 degC and 0,5 A at 85 C.
The max. off-voltage is 33 V. (The outputs are protected by 33V TVS - Transient Voltage Suppression).
Source Output 470
Ω/ 2 W