BRP-Rotax
REPAIR MANUAL
Figure 3.2: Battery
1
Battery cover
2
O-ring
3
Allen screw with rounded flange head
4
Positive battery terminal
5
Negative battery terminal
_________________________________________________
Instruction
See
4.
Pull the spark plug connector (1) off the spark plug. Minimum removal force 30 N.
5.
Remove the cable tie (11).
6.
Disconnect the plug connections (6) on the ignition coil (2).
7.
Disconnect the plug connection (7) on the solenoid valve (5).
8.
Disconnect the connector (9) for the pick up sensor (3)
9.
Disconnect the connector (10) for the starter (4).
Page 4
November 01 2021
Effectivity: 125 MAX evo, Junior MAX
evo, Mini MAX evo, Micro MAX evo