PG.
33
SUMMARY MENU
MENU
DESCRIPTION
CFF / DCFF
CFV
2
Vibration Amplitude
.
.
or
.
.
.
.
or
.
.
3
Frequency
.
(33 Hz; 50 Hz; 100
Hz)
.
.
(20÷140 Hz)
4
Tracking or Calibrated Tracking
Not available
.
(0=Normal loop; 1 =.
Calibrated tracking loop)
4/1
Autocalibration
Not available
.
(0=Off; 1 =On)
5
Integrator Gain
.
.
(1; 2; 4; 8)
.
.
(1; 2; 4; 8)
6
Sensor 1 (Sensor 3 for vibr.2 DCFF)
.
(0=Off; 1 =On)
.
(0=Off; 1 =On)
6/1
Sensor 1: Light/Dark (S3 vibr.2 DCFF)
−
.
(-S1=0=Light; -
S1=1=Dark)
−
.
(-S1=0=Light; -
S1=1=Dark)
6/2
Sensor 1: Delay ON (S3 vibr. 2 DCFF)
.
.
(Da 0 sec. A 25,5
sec)
.
.
(Da 0 sec. A 25,5
sec)
6/3
Sensor 1: Delay OFF (S3 for vibr. 2 DCFF)
.
.
(Da 0 sec. A 25,5
sec)
.
.
(Da 0 sec. A 25,5
sec)
7
Sensor 2 (Sensor 4 for vibr. 2 DCFF)
.
(0=Off; 1 =On)
.
(0=Off; 1 =On)
7/1
Sensor 2: Light or Dark (S4 for vibr. 2 DCFF)
−
.
(-S1=0=Light; -
S1=1=Dark)
−
.
(-S1=0=Light; -
S1=1=Dark)
7/2
Sensor 2: Delay ON (S4 for vibr. 2 DCFF)
.
.
( 0 sec. A 25,5 sec)
.
.
( 0 sec. A 25,5 sec)
7/3
Sensor 2: Delay OFF (S4 for vibr. 2 DCFF)
.
.
( 0 sec. A 25,5 sec)
.
.
( 0 sec. A 25,5 sec)
8
0 – 10 Volts
−
.
(0=Off; 1 =On)
−
.
(0=Off; 1 =On)
8/1
0 – 10 Volts: Light or Dark
−
.
=Direct
−
.
=Denied
−
.
=Direct
−
.
=Denied
9
Synchronism
Only with MASTER board
Only with MASTER board
10
Probe
.
(0=Off; 1 =On)
.
(0=Off; 1 =On)
10/1
K.Probe Value
.
typical
.
typical
10/2
Filter
.
(0=Off; 1 =On)
.
(0=Off; 1 =On)
11
1A, 2A, 3A
See Pg. 21
See Pg. 21
12
Emergency
Only with MASTER board
Only with MASTER board
13
Correction % Synchronism
Only with MASTER board
Only with MASTER board
14
Calibration
.
.
Amax value
.
.
Amax value
14/1
Calibration from fixed point (0-10V)
.
(0=Off; 1 =On)
.
(0=Off; 1 =On)
14/2
Full calibration
Not available
.
(0=Off; 1 =On)
15
Output relay
State relay
Actuator control
MASTER only
Balance
Elevator. DCFF only
Unit. DCFF only
State relay n.1
Actuator control
MASTER only
Balance
(Null)
(Null)
State Relay n. 2
16
Maximum current
Not available
.
.
=Max value
17
Simultaneous stop of two vibrators
.
DCFF Only
Not available
17/1
Synchronism of DCFF1 and DCFF2
.
DCFF Only
18
A max (No SRV02)
.
.
.
.
18/1
A0 setting with 1000 step
(0=Off; 1 =On)
(0=Off; 1 =On)
19
Ramp. Soft-Start and Soft-Stop
.
(0=Off; 1 =On)
.
(0=Off; 1 =On)
19/1
Ramp. Times
.
e
.
.
e
.
20
A0 setting as default parameter
.
(0=Off; 1 =On)
.
(0=Off; 1 =On)
21
Pieces-counter setting as default parameter
24
Internal temperature
°
.
.
°
.
.
25
Resonance frequency
.
.
Only after calibration
.
.
Only after calibration
26
Pieces-counter function: Display
.
Visual. Counter
Not available
26/1
Pieces-counter function: Display
Visual. Totalizer
Not available
26/2
Pieces-counter function: Display
Reset totalizer
Not available
27
Pieces- counter function: Setting
Set pieces-counter
Not available
27/1
Pieces-counter function: Setting
Intermediate reset
Not available
27/2
Pieces-counter function: Setting
Intermediate threshold
Intermediate threshold
27/3
Pieces-counter function: Setting
Pieces to count
Pieces to count
28
Time Out function
.
.
(0=Off; 1 =On)
.
.
(0=Off; 1 =On)
28/1
Time Out function: Selecting sensor
.
S1, S2, (S3, S4)
.
S1, S2
28/2
Time Out function: Setting time
.
(30 – 250)
.
(30 – 250)
MENU
DESCRIPTION
CFF/DCFF
CFV
30
Default: Reset inspection parameters
.
(0=Off; 1 =On)
.
(0=Off; 1 =On)
31
Reset controller
.
(0=Off; 1 =On)
.
(0=Off; 1 =On)
34
Motor function
.
(0=Off; 1=On)
Not available
34/1
Motor function: Toggle
.
(0=Off; 1=On)
Not available
Содержание CFF Series