6.1.1 Ribbon and Gap/Black Mark Sensor Calibration
Calibrate the Gap/Black Mark Sensor sensitivity when:
You purchase a new printer.
You change label stock.
The label printer initializes.
To calibrate the Ribbon and Gap/Black Mark Sensors:
1. Turn off the printer.
2. Press and hold the right
Selection
button, and then turn on the Power Switch.
3. Release the button when
Sensor Calibration
appears on the screen.
Note
The LED color will change as follows:
Amber (lit)
red (5 times)
amber (5 times)
green (5 times)
green/amber (5 times)
red/amber (5 times)
green (lit)
To select the sensor for calibration, send the correct command to the printer:
For the Gap Sensor: send the GAP command
For the Black Mark Sensor: send the BLINE command
For more information about the available commands, see the
FBPL Command Reference
on your model's
Manuals