S-7780A
4. USING THE OPERATION PANEL (ADVANCED OPERATIONS)
37
Standard device settings (500 to 599)
No.
Setting
range
Initial
value
Setting
units
Setting details
500
OFF, 1 - 3
1
1
Presser foot lifter SW function
OFF: Disabled
1: Presser foot lifter switch
2: Puller switch (switching)
3: Puller switch
* Puller operation is enabled when No. 960 is set to "1", and it does not
operate when set to other than "OFF".
501
OFF, 1 - 2
OFF
1
Thread holder operation setting
OFF: Thread holder does not operate
1: On according to the timing set by No. 502, and off according to the timing
set by No. 503
2: On together with starting of machine motor, and off according to the timing
set by No. 503
502
90 - 270
(Degrees)
180
(Degrees)
1
Thread presser ON timing (upper shaft angle)
(*) When No. 501 is set to "OFF" or "2", nothing is displayed. (The setting is
disabled.)
503
270 - 430
(Degrees)
320
(Degrees)
1
Thread presser OFF timing (upper shaft angle)
(*) When No. 501 is set to "OFF", nothing is displayed. (The setting is
disabled.)
504
-50 - 50
(Degrees)
0
(Degrees)
1
Feed timing for 1st stitch at sewing start *1
505
-50 - 50
(Degrees)
0
(Degrees)
1
Feed timing for 2nd stitch at sewing start *1
506
-50 - 50
(Degrees)
0
(Degrees)
1
Feed timing for 3rd stitch at sewing start *1
507
-50 - 50
(Degrees)
0
(Degrees)
1
Feed timing for 1st stitch at sewing end *2
508
-50 - 50
(Degrees)
0
(Degrees)
1
Feed timing for 2nd stitch at sewing end *2
509
-50 - 50
(Degrees)
0
(Degrees)
1
Feed timing for 3rd stitch at sewing end *2